Dongan 85-LM025 85 Low Voltage Transformer, 240x480 VAC Primary, 24/48 VDC Secondary, 0.5 kVA, 50/60 Hz, 1 Phase

Transformers, Low Voltage Signaling
PDW~50311 MFG #: 85-LM025
Dongan
205.40000 / ea
  • Catalog Number: 85-LM025
  • Connection Type: Lead Wire
  • Country of Origin: USA
  • Dimensions: 12 in H x 4.87 in W x 5.25 in D
  • Enclosure Type: NEMA 3R
  • Gross Weight Per Pack: 19.0000 lb
  • Maximum Amperage Rating: 2/1/20.8/10.4 A
  • Mounting Type: Wall
  • Series: 85
  • Standards: UL/cUL Listed
  • Type: Low Voltage
  • UNSPSC: 39121025
  • UPC 11: 78249035725
  • Stock Status: NONSTOCK
  • Brand: Dongan
  • Manufacturer: Dongan Electric
  • Frequency Rating: 50/60 Hz
  • Phase: 1
  • Power Rating: 0.5 kVA
  • Primary Voltage: 240x480 VAC
  • Secondary Voltage: 24/48 VDC
Dongan Transformer, Low Voltage, Series: 85, 240x480 VAC Primary, 24/48 VDC Secondary, 0.5 kVA, 50/60 Hz, 1 Phase, 2/1/20.8/10.4 A Maximum, Lead Wire, Wall Mount, 180 deg C, NEMA 3R, 12 in H x 4.87 in W x 5.25 in D
QTY
  • Features
Load Amps At Buck - Decrease Voltage: 22.9 AMP At 230 V Load And 253 V Line, 12.2 AMP At 230 V Load And 277 V Line, 22.9 AMP At 240 V Load And 264 V Line, 12.5 AMP At 240 V Load And 288 V Line, 21.8 AMP At 480 V Load And 504 V Line, 11.4 AMP At 480 V Load And 528 V Line; Load Amps At Boost - Increase Voltage: 10.4 AMP At 240 V Load And 192 V Line, 10.4 AMP At 240 V Load And 200 V Line, 20.8 AMP At 240 V Load And 216 V Line, 20.8 AMP At 240 V Load And 218 V Line, 10.4 AMP At 480 V Load And 432 V Line, 10.5 AMP At 480 V Load And 437 V Line, 20.8 AMP At 480 V Load And 456 V Line, 20.6 AMP At 480 V Load And 457 V Line; Line Fuse At Buck - Decrease Voltage: 30 V At 230 V Load And 253 V Line, 15 V At 230 V Load And 277 V Line, 30 V At 240 V Load And 264 V Line, 15 V At 240 V Load And 288 V Line, 30 V At 480 V Load And 504 V Line, 15 V At 480 V Load And 528 V Line; Kva
Electrostatic shield between primary and secondary windings provides cleaner output voltage and helps to reduce spikes and transients
Epoxy-silica encapsulated core and coil provides a transformer particularly well suited for harsh commercial and industrial applications
Copper windings and copper lead wire terminations used throughout
UL class 180 deg C insulation system with 115 deg C temperature rise at a maximum ambient of 40 deg C
Wall mount enclosure suitable for indoor or outdoor use
May be used in banks of 2 or 3 units for standard three phase voltages and nonstandard, open delta autotransformer/applications
Multiple knockouts provide convenient conduit entry and exit locations through the front and bottom access wiring compartment covers
Ground studs provided for bonding compatibility with both metallic and nonmetallic conduit