Schneider Electric XPSDMB1132P Preventa™ Solid State Safety Relay, 2NO Contact Form, 24 VDC Coil

Safety Relays
220466 MFG #: XPSDMB1132P
Schneider Electric
330.00000 / ea
  • Alternate Catalog Number: XPSDMB1132P
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: XPSDMB1132P
  • Country of Origin: ID
  • Currency: USD
  • Dimensions: 99 mm H x 22.5 mm W x 114 mm D
  • Display Type: LED
  • Enclosure Type: IP20/IP40
  • EU RoHS Indicator: Y
  • Frequency Rating: 50/60 Hz
  • Gross Volume Per Pack: 22.18
  • Gross Volume per Pack Metric: 363.46
  • Gross Weight Per Pack: 0.4600 lb
  • Gross Weight per Pack Metric: 0.20
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8537109170
  • Height: 1.10 in
  • Height [Metric]: 2.7940 cm
  • Item Group: 22477
  • Length: 4.80 in
  • Length [Metric]: 12.1920 cm
  • Material Composition Declaration: https://www.reach.schneider-electric.com/DistantRequestDispatcher.aspx?action=export&pid=1460772&lang=en-us
  • Mounting Type: DIN Rail
  • Power Rating: 2.5 W
  • Returnable: N
  • Series: XPSDMB
  • Temperature Rating: -14 to 130 °F
  • Terminal Type: Screw/Clamp
  • Type: Solid State
  • UNSPSC: 32151802
  • UPC 11: 78590134427
  • UPC 12: 785901344278
  • Warranty Description: Contractual Warranty: 18 months
  • Width: 4.20 in
  • Width [Metric]: 10.6680 cm
  • Stock Status: NONSTOCK
  • Brand: Schneider Electric
  • Manufacturer: Schneider Electric
  • Coil Voltage: 28 VDC
  • Contact Form: 2NO
Schneider Electric XPSDMB1132P m,2 N.O. (Instananeous) 2 Solid State,28 V DC,3 LED Indicators -14 to 130 Degrees F,35 mm symmetrical DIN rail,EN 954-1 Category 4 (Standard) - Category 3 (If wired in series),Preventa,Preventa Safety automation,coded magnetic switch monitoring,monitoring 2 coded magnetic switches,Preventa safety module,Terminal Block (removable) Screw Clamp
QTY
  • Features
IP20 TERMINALS)EN/IEC 60529-IP40 ENCLOSURE)EN/IEC 60529
Safety relay modules XPSDMB and XPSDME are specifically designed for monitoring coded magnetic safety switches
They incorporate two safety outputs and two solid-state outputs for signaling to the process PLC
XPSDMB safety relay modules can monitor two independent sensors and modules XPSDME can monitor up to six independent sensors
To aid diagnostics, the modules have LEDs on the front cover which provide information on the monitoring circuit status
2-solid state
Safety modules XPSDMP incorporate removable terminal blocks, thus optimizing machine maintenance