Appleton® ECP-1523 U-Line Interchanger™ ECP1523 Dust Ignitionproof Explosionproof Standard Plug, 125 VAC, 15 A, 3 Poles, 2 Wires, Black/White
Custom_Product_Images_Illustration
Appleton® ECP-1523 U-Line Interchanger™ ECP1523 Dust Ignitionproof Explosionproof Standard Plug, 125 VAC, 15 A, 3 Poles, 2 Wires, Black/White
SKU17078
MFGR #ECP-1523
Your Cost: $198.82/ea
Appleton offers the CSA certified U-Line® Series. These plugs and receptacles allow the use of electrical equipment in hazardous locations. In non-hazardous locations, the U-Line ECP plug fits into standard 5-15R, 5-20R, or 6-20R receptacles. In hazardous locations, the same U-Line plug is the key to energizing the explosionproof U-Line receptacle. Although U-Line plugs can be used with ordinary receptacles, U-Line receptacles are designed so that they can't be energized by an ordinary plug-ensuring that only safe connections can be made in a hazardous location. It's an convenient, time and money-saving solution for handheld tools, lighting and other equipment that might be used in both ordinary and hazardous locations. When using a U-Line plug-in an explosionproof U-Line receptacle, a twist of the plug makes electrical contact and locks the plug-in place with an audible click. The neoprene gasket in the throat of the receptacle seals against the plug or the spring-loaded cover to seal out water, dust and corrosive compounds.
Appleton offers the CSA certified U-Line® Series. These plugs and receptacles allow the use of electrical equipment in hazardous locations. In non-hazardous locations, the U-Line ECP plug fits into standard 5-15R, 5-20R, or 6-20R receptacles. In hazardous locations, the same U-Line plug is the key to energizing the explosionproof U-Line receptacle. Although U-Line plugs can be used with ordinary receptacles, U-Line receptacles are designed so that they can't be energized by an ordinary plug-ensuring that only safe connections can be made in a hazardous location. It's an convenient, time and money-saving solution for handheld tools, lighting and other equipment that might be used in both ordinary and hazardous locations. When using a U-Line plug-in an explosionproof U-Line receptacle, a twist of the plug makes electrical contact and locks the plug-in place with an audible click. The neoprene gasket in the throat of the receptacle seals against the plug or the spring-loaded cover to seal out water, dust and corrosive compounds.
Application Fits Any Standard Non-Explosionproof Receptacle As Well As U-Line Explosionproof Receptacles ARRA Compliant N Buy American Compliant N Catalog Number ECP-1523 Cord Diameter 0.538 to 0.639 in Country of Origin MX Currency USD Dimensions 2.78 in H x 1.75 in W EU RoHS Indicator C Gross Weight Per Pack 0.4550 lb Gross Weight per Pack Metric 0.14 Gross Weight UOM Metric kg Height 3.50 in Height [Metric] 8.8900 cm Length 4.50 in Length [Metric] 11.4300 cm Material Copper Free Aluminum NEMA Rating NEMA 7BCD/9G Number Of Poles 3 Standard Class I, Division 1 And 2, Groups B, C, D; Class II, Division 1 And 2, Group G and Coal Dust; Class III Standards RoHS CompliantCSA CertifiedUL Listed for Class I, Div 1 and 2, Groups B, C, D, Class II, Div 1 and 2, Group G and Coal Dust, Class III Sub Brand U-Line Type ECP Standard Plug UNSPSC 39121402 UPC 11 78138124920 UPC 12 781381249201 Width 4.00 in Width [Metric] 10.1600 cm Stock Status NORMALLY STOCKED Brand Appleton™ Manufacturer Appleton Amperage Rating 15 A Color Black/White Number of Wires 2 Voltage Rating 125 VAC Fits Any Standard Non-Explosionproof Receptacle As Well As U-Line Explosionproof Receptacles Explosionproof, dust-ignitionproof; Suitable for use in such areas as refineries, petrochemical plants, and other areas subject to where ignitable gases are present; Unique blade-type, brass contacts exert constant pressure along entire contact surface and provide superior electrical contact; Insulators provide superior dielectric and mechanical strength and lowest arc tracking; Longer plug housing for better gripping and easier plug insertion and withdrawal; Plugs fits any standard non-explosionproof receptacle (NEMA 5-15R, 5-20R or 6-20R) as well as U-Line explosionproof receptacles; A twist of the plug produces audible click to indicate fast make and break of built-in switch contacts; Twisting plug locks it in place and cannot be accidentally pulled out; For use in the T-slot configured 20 AMP U-Line receptacle Explosion proof and dust-ignition proof Suitable for use in such areas as refineries, petrochemical plants, and other areas subject to where ignitable gases are present Unique blade-type, brass contacts exert constant pressure along entire contact surface and provide superior electrical contact Insulators provide superior dielectric and mechanical strength and lowest arc tracking Longer plug housing for better gripping and easier plug insertion and withdrawal Plugs fits any standard non-explosion proof receptacle (NEMA 5-15R, 5-20R or 6-20R) as well as U-Line explosion proof receptacles A twist of the plug produces audible click to indicate fast make and break of built-in switch contacts Twisting plug locks it in place and cannot be accidentally pulled out U-Line plugs can be used with U-Line explosionproof receptacles as well as standard receptacles To ensure safety in hazardous locations, standard plugs cannot be used in U-Line receptacles U-Line factory sealed 15 and 20 Amp plugs and receptacles The U-Line Interchanger™ ECP plug is suitable for use in refineries, petrochemical plants and other areas where ignitable gases are present
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Application | Fits Any Standard Non-Explosionproof Receptacle As Well As U-Line Explosionproof Receptacles |
ARRA Compliant | N |
Buy American Compliant | N |
Catalog Number | ECP-1523 |
Cord Diameter | 0.538 to 0.639 in |
Country of Origin | MX |
Currency | USD |
Dimensions | 2.78 in H x 1.75 in W |
EU RoHS Indicator | C |
Gross Weight Per Pack | 0.4550 lb |
Gross Weight per Pack Metric | 0.14 |
Gross Weight UOM Metric | kg |
Height | 3.50 in |
Height [Metric] | 8.8900 cm |
Length | 4.50 in |
Length [Metric] | 11.4300 cm |
Material | Copper Free Aluminum |
NEMA Rating | NEMA 7BCD/9G |
Number Of Poles | 3 |
Standard | Class I, Division 1 And 2, Groups B, C, D; Class II, Division 1 And 2, Group G and Coal Dust; Class III |
Standards | RoHS CompliantCSA CertifiedUL Listed for Class I, Div 1 and 2, Groups B, C, D, Class II, Div 1 and 2, Group G and Coal Dust, Class III |
Sub Brand | U-Line |
Type | ECP Standard Plug |
UNSPSC | 39121402 |
UPC 11 | 78138124920 |
UPC 12 | 781381249201 |
Width | 4.00 in |
Width [Metric] | 10.1600 cm |
Stock Status | NORMALLY STOCKED |
Brand | Appleton™ |
Manufacturer | Appleton |
Amperage Rating | 15 A |
Color | Black/White |
Number of Wires | 2 |
Voltage Rating | 125 VAC |
Fits Any Standard Non-Explosionproof Receptacle As Well As U-Line Explosionproof Receptacles |
Explosionproof, dust-ignitionproof; Suitable for use in such areas as refineries, petrochemical plants, and other areas subject to where ignitable gases are present; Unique blade-type, brass contacts exert constant pressure along entire contact surface and provide superior electrical contact; Insulators provide superior dielectric and mechanical strength and lowest arc tracking; Longer plug housing for better gripping and easier plug insertion and withdrawal; Plugs fits any standard non-explosionproof receptacle (NEMA 5-15R, 5-20R or 6-20R) as well as U-Line explosionproof receptacles; A twist of the plug produces audible click to indicate fast make and break of built-in switch contacts; Twisting plug locks it in place and cannot be accidentally pulled out; For use in the T-slot configured 20 AMP U-Line receptacle |
Explosion proof and dust-ignition proof |
Suitable for use in such areas as refineries, petrochemical plants, and other areas subject to where ignitable gases are present |
Unique blade-type, brass contacts exert constant pressure along entire contact surface and provide superior electrical contact |
Insulators provide superior dielectric and mechanical strength and lowest arc tracking |
Longer plug housing for better gripping and easier plug insertion and withdrawal |
Plugs fits any standard non-explosion proof receptacle (NEMA 5-15R, 5-20R or 6-20R) as well as U-Line explosion proof receptacles |
A twist of the plug produces audible click to indicate fast make and break of built-in switch contacts |
Twisting plug locks it in place and cannot be accidentally pulled out |
U-Line plugs can be used with U-Line explosionproof receptacles as well as standard receptacles |
To ensure safety in hazardous locations, standard plugs cannot be used in U-Line receptacles |
U-Line factory sealed 15 and 20 Amp plugs and receptacles |
The U-Line Interchanger™ ECP plug is suitable for use in refineries, petrochemical plants and other areas where ignitable gases are present |