Bussmann® FRS-R-100 Fusetron™ FRS-R Current Limiting Time Delay Fuse, 100 A, 600 VAC/300 VDC, 200/20 kA Interrupt, Class RK5

Class RK5 Fuses
5152 MFG #: FRS-R-100
Bussmann
61.32000 / ea
  • Alternate Catalog Number: FRS-R-100
  • Application: Ind Facilities & Factories - Facility: Safety and Security Systems
  • ARRA Compliant: C
  • Body Size: 1.11 in Dia x 7.88 in L
  • Buy American Compliant: C
  • Catalog Number: FRS-R-100
  • Connection: Blade end x blade end
  • Country of Origin: MX
  • Currency: USD
  • Element: Dual
  • EU RoHS Indicator: C
  • Gross Weight Per Pack: 0.4000 lb
  • Gross Weight per Pack Metric: 0.18
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536100040
  • Height: 1.30 in
  • Height [Metric]: 3.3020 cm
  • Length: 8.00 in
  • Length [Metric]: 20.3200 cm
  • Material: Fiberglass
  • Mounting Type: Holder
  • Response Time: 10 S at 500%
  • Series: FRS-R
  • Size: 1.11 In Diameter X 7.88 In Length
  • Standard: CE Marked
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantCE CertifiedUL 248-12 File No. E4273 Guide JDDZCSA File No. 53787 C22.2 No. 248.12 Class 1422-02
  • Sub Brand: Bussmann Series
  • Terminal Type: Knife Blade
  • Type: Fuse
  • UNSPSC: 39121606
  • UPC 11: 05171250843
  • UPC 12: 051712508438
  • Width: 1.30 in
  • Width [Metric]: 3.3020 cm
  • Stock Status: NORMALLY STOCKED
  • Brand: Bussmann
  • Manufacturer: Eaton
  • Amperage Rating: 100 A
  • Class: RK-5
  • Interrupt Rating: 200 kAIC at 600 Vac20 kAIC at 300 Vdc
  • Voltage Rating: 600//300 VAC//VDC
Time-delay affords the same excellent overload protection as low peak fuses of motors and other type loads and circuits having temporary inrush currents such as those caused by transformers and solenoids. (In such circuits, Limitron fuses can only provide short circuit protection). Fusetron fuses are not as Fast-Acting on short circuits as low peak fuses and therefore cannot give as high a degree of componet short circuit protection. Like the low peak fuse, Fusetron fuses permit the use of smaller size and less costly switches. Fusetron fuses fit rejection type fuse holders and can also be installed in holders for Class H fuses. They can physically and electrically replace Class H, K5, and other Class RK5 fuses.
QTY
  • Applications
  • Features
Ind Facilities & Factories - Facility: Safety and Security Systems
Renewable
Provides motor overload, ground fault and short circuit protection
When used in circuits subject to surge currents such as those caused by motors, transformers and other inductive components, these fuses can be sized close to full-load amps to give maximum overcurrent protection
The time delay feature makes it possible to use fuse amperage ratings which are much smaller than those of non-time delay fuses
Considerable cost saving occurs by permitting the use of smaller size switches, panels and fuses themselves
Provides a good deg of short circuit protection (greater current limitation) to help protect downstream components from high fault currents
Gives motor running back up protection to motors without extra costs
Helps protect motors against burnout from overloads and single phasing when sized properly
Simplifies and improves blackout prevention (selective coordination ratios)
Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection