Bussmann® Low-Peak™ LPS-RK-25SP LPS-RK-SP Time Delay Fuse, 25 A, 600 VAC/300 VDC, 300/100 kA Interrupt, Class RK1, Cylindrical Body

Class RK1 Fuses
5280 MFG #: LPS-RK-25SP
Bussmann
24.89000 / ea
  • Alternate Catalog Number: LPS-RK-25SP
  • Application: Ind Facilities & Factories - Facility: Safety and Security Systems
  • ARRA Compliant: C
  • Body Size: 13/16 in Dia x 5 in L
  • Buy American Compliant: C
  • Catalog Number: LPS-RK-25SP
  • Connection: Ferrule end x ferrule end
  • Country of Origin: MX
  • Currency: USD
  • Element: Dual
  • EU RoHS Indicator: C
  • Gross Weight Per Pack: 0.1000 lb
  • Gross Weight per Pack Metric: 0.73
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536100040
  • Height: 0.81 in
  • Height [Metric]: 2.0574 cm
  • Length: 5.00 in
  • Length [Metric]: 12.7000 cm
  • Material: Melamine
  • Mounting Type: Holder
  • Response Time: 8 S at 500%
  • Series: LPS-RK
  • Size: 0.81 In Diameter X 5.00 In Length
  • Standard: CE Marked
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantCE CertifiedGuide No. JFHR UL File No. E56412CSA Class 1422-02CSA File No. 53787CSA C22.2CSA File No. 248.12
  • Sub Brand: Bussmann Series
  • Terminal Type: Ferrule
  • Type: Fuse
  • UNSPSC: 39121606
  • UPC 11: 05171254835
  • UPC 12: 051712548359
  • Width: 0.81 in
  • Width [Metric]: 2.0574 cm
  • Stock Status: NORMALLY STOCKED
  • Brand: Bussmann
  • Manufacturer: Eaton
  • Amperage Rating: 25 A
  • Class: RK-1
  • Interrupt Rating: 100 kAIC at 300 Vdc300 kAIC at 600 Vac
  • Voltage Rating: 600//300 VAC//VDC
Ultimate protection Class RK1 dual element, current-limiting, time-delay fuses available with optional open fuse indication on select ratings. Time-delay 10 seconds (minimum) at 500% of rated current.
QTY
  • Applications
  • Features
Ind Facilities & Factories - Facility: Safety and Security Systems
Electrically Isolated End Cap
Fast short circuit protection and dual element, time-delay performance provide ultimate protection
Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak™ fuses
Consistent 2:1 ampacity ratios for all low peak fuses make selective coordination easy
Time-delay permits sizing as close as 130% of motor Full Load Amps (FLA) for back-up overload protection
Current limitation protects downstream components against damaging thermal and magnetic effects of short circuit currents
Protects against single phase motor damage
Proper sizing can provide No Damage Type 2 motor starter protection for NEMA® and the international electrotechnical commission (IEC) motor controllers
300 kA VAC RMS Sym, 100 kA VDC