or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Telemecanique XESB2011 XESB Single Contact Block, 1 Poles, 10 A at 600 VAC, For Use With XACM/XAB91/XACB Series Contact Block
Custom_Product_Images_Illustration
Telemecanique XESB2011 XESB Single Contact Block, 1 Poles, 10 A at 600 VAC, For Use With XACM/XAB91/XACB Series Contact Block
SKU97493
MFGR #XESB2011
$/ea
Schneider Electric XESB2011 PENDANT STATION CONTACT 600VAC 10A XE,-13...158 deg.F (-25...70 deg.C),1 NO + 1 NC,10 A,500 V,EN/IEC, CSA,Harmony XAC,XAB91..., XACB, XACM,contact block,contact block,screw clamp terminals,snap action,spring return
Schneider Electric XESB2011 PENDANT STATION CONTACT 600VAC 10A XE,-13...158 deg.F (-25...70 deg.C),1 NO + 1 NC,10 A,500 V,EN/IEC, CSA,Harmony XAC,XAB91..., XACB, XACM,contact block,contact block,screw clamp terminals,snap action,spring return
Catalog Number XESB2011 Country of Origin CZ Gross Weight Per Pack 0.3000 lb Height 4.3000 Length 8.6000 Standards EN 60947-5-1, CSA C22.2 No 14 Certified, IEC 60947-5-1 Standard UNSPSC 39121522 Width 6.4000 Stock Status NONSTOCK Brand Square D™ Manufacturer Schneider Electric Single speed;XACM;XACB;XAB91... CONTACT BLOCK Snap action contacts operation 1 x 2.5 mm2 with or without cable end screw clamp terminals, connection capacity, 2 x 1.5 mm2 with or without cable end screw clamp terminals, connection capacity connections terminals 1000000 cycles mechanical durability 500 V (3 deg of pollution) conforming to IEC 60947-1 rated insulation voltage 6 kV conforming to IEC 60947-1 rated impulse withstand voltage <= 25 M ohm resistance across terminals 10 A fuse protection by cartridge fuse type gG short circuit protection 140 W DC-13 for 1000000 cycles, 60 cyc/mn at 24 V operating rate, 0.5 (inductive load) load factor conforming to IEC 60947-5-1, 140 W DC-13 for 1000000 cycles, 60 cyc/mn at 48 V operating rate, 0.5 (inductive load) load factor conforming to IEC 60947-5-1, 95 W DC-13 for 1000000 cycles, 60 cyc/mn at 120 V operating rate, 0.5 (inductive load) load factor conforming to IEC 60947-5-1 rated operational power in W 100 VA AC-15 for 1000000 cycles, 60 cyc/mn at 48 V 50/60 Hz operating rate, 0.5 (inductive load) load factor, 450 VA AC-15 for 1000000 cycles, 60 cyc/mn at 127 V 50/60 Hz operating rate, 0.5 (inductive load) load factor, 50 VA AC-15 for 1000000 cycles, 60 cyc/mn at 24 V 50/60 Hz operating rate, 0.5 (inductive load) load factor, 750 VA AC-15 for 1000000 cycles, 60 cyc/mn at 230 V 50/60 Hz operating rate, 0.5 (inductive load) load factor rated operational power in VA -25 to 70 deg C operation temperature -40 to 70 deg C storage temperature
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Catalog Number | XESB2011 |
| Country of Origin | CZ |
| Gross Weight Per Pack | 0.3000 lb |
| Height | 4.3000 |
| Length | 8.6000 |
| Standards | EN 60947-5-1, CSA C22.2 No 14 Certified, IEC 60947-5-1 Standard |
| UNSPSC | 39121522 |
| Width | 6.4000 |
| Stock Status | NONSTOCK |
| Brand | Square D™ |
| Manufacturer | Schneider Electric |
| Single speed;XACM;XACB;XAB91... |
| CONTACT BLOCK |
| Snap action contacts operation |
| 1 x 2.5 mm2 with or without cable end screw clamp terminals, connection capacity, 2 x 1.5 mm2 with or without cable end screw clamp terminals, connection capacity connections terminals |
| 1000000 cycles mechanical durability |
| 500 V (3 deg of pollution) conforming to IEC 60947-1 rated insulation voltage |
| 6 kV conforming to IEC 60947-1 rated impulse withstand voltage |
| <= 25 M ohm resistance across terminals |
| 10 A fuse protection by cartridge fuse type gG short circuit protection |
| 140 W DC-13 for 1000000 cycles, 60 cyc/mn at 24 V operating rate, 0.5 (inductive load) load factor conforming to IEC 60947-5-1, 140 W DC-13 for 1000000 cycles, 60 cyc/mn at 48 V operating rate, 0.5 (inductive load) load factor conforming to IEC 60947-5-1, 95 W DC-13 for 1000000 cycles, 60 cyc/mn at 120 V operating rate, 0.5 (inductive load) load factor conforming to IEC 60947-5-1 rated operational power in W |
| 100 VA AC-15 for 1000000 cycles, 60 cyc/mn at 48 V 50/60 Hz operating rate, 0.5 (inductive load) load factor, 450 VA AC-15 for 1000000 cycles, 60 cyc/mn at 127 V 50/60 Hz operating rate, 0.5 (inductive load) load factor, 50 VA AC-15 for 1000000 cycles, 60 cyc/mn at 24 V 50/60 Hz operating rate, 0.5 (inductive load) load factor, 750 VA AC-15 for 1000000 cycles, 60 cyc/mn at 230 V 50/60 Hz operating rate, 0.5 (inductive load) load factor rated operational power in VA |
| -25 to 70 deg C operation temperature |
| -40 to 70 deg C storage temperature |