or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Square D™
SQD METSEPM5560 Intermediate Power Meter Cl 0.2 Ethernet Port
Custom_Product_Images_Illustration
Square D™
SQD METSEPM5560 Intermediate Power Meter Cl 0.2 Ethernet Port
SKU950028
MFGR #METSEPM5560
$/ea
Schneider Electric,Intermediate Power Meter Cl 0.2 Ethernet Port,PowerLogic,power meter
Schneider Electric,Intermediate Power Meter Cl 0.2 Ethernet Port,PowerLogic,power meter
Catalog Number METSEPM5560 Country of Origin US Gross Weight Per Pack 5.9800 lb Height 11.0000 Length 12.6000 Standards UL 61010-1IEC 62053-24CE CertifiedIEC 61010-1cULus ListedUL 61010-1BTLIEC 60529IEC 61557-12IEC 62053-22EN 50470-1EN 50470-3 UNSPSC 39121106 Width 12.6000 Stock Status NONSTOCK Brand Square D™ Manufacturer Schneider Electric Gateway;WAGES metering;power monitoring;multi-tariff 128 SAMPLES/CYCLE,ALARM NOTIFICATION BY E-MAIL-DIAGNOSTIC VIA PREDEFINED WEB PAGES-WEB SERVER-REAL TIME VIEWING OF DATA Class 0.2 serial port and dual Ethernet PM5560 device short name, up to the 63rd harmonic power quality analysis 1P+N, 3P, 3P+N poles, 128 x 128 pixels resolution Sampling rate of 128 samples/cycle 5 mA to 10 A measurement current, 20 to 400 VAC 45 to 65 Hz between phase and neutral, 20 to 690 VAC 45 to 65 Hz between phases measurement voltage 4 digital input, 2 digital output Class 0.2S (active energy according to IEC 62053-22) accuracy class Modbus RTU and ASCII 2 wires: 9.6, 19.2 and 38.4 kbauds, even/odd or none, insulation: 2500 VAC, JBUS, Modbus TCP/IP: 10/100 Mbit/s, insulation: 2500 VAC, Ethernet Modbus, TCP/IP daisy chain, BACnet IP communication port protocol 1.1 MB memory capacity, flush mounted IP52 (front) conforming to IEC 60529, IP30 (body) conforming to IEC 60529 IP degree of protection 5 to 95% 122 deg F relative humidity, 2 pollution degree, 9842.52 ft operating altitude -13 to 158 deg F ambient air temperature for operation, -40 to 185 deg F ambient air temperature for storage +/-0.05% frequency, +/-0.2% active energy, +/-1% reactive energy, +/-0.2% active power, +/-0.1% voltage, +/-0.05% power factor, +/-0.15 deg C current
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Catalog Number | METSEPM5560 |
| Country of Origin | US |
| Gross Weight Per Pack | 5.9800 lb |
| Height | 11.0000 |
| Length | 12.6000 |
| Standards | UL 61010-1IEC 62053-24CE CertifiedIEC 61010-1cULus ListedUL 61010-1BTLIEC 60529IEC 61557-12IEC 62053-22EN 50470-1EN 50470-3 |
| UNSPSC | 39121106 |
| Width | 12.6000 |
| Stock Status | NONSTOCK |
| Brand | Square D™ |
| Manufacturer | Schneider Electric |
| Gateway;WAGES metering;power monitoring;multi-tariff |
| 128 SAMPLES/CYCLE,ALARM NOTIFICATION BY E-MAIL-DIAGNOSTIC VIA PREDEFINED WEB PAGES-WEB SERVER-REAL TIME VIEWING OF DATA |
| Class 0.2 serial port and dual Ethernet |
| PM5560 device short name, up to the 63rd harmonic power quality analysis |
| 1P+N, 3P, 3P+N poles, 128 x 128 pixels resolution |
| Sampling rate of 128 samples/cycle |
| 5 mA to 10 A measurement current, 20 to 400 VAC 45 to 65 Hz between phase and neutral, 20 to 690 VAC 45 to 65 Hz between phases measurement voltage |
| 4 digital input, 2 digital output |
| Class 0.2S (active energy according to IEC 62053-22) accuracy class |
| Modbus RTU and ASCII 2 wires: 9.6, 19.2 and 38.4 kbauds, even/odd or none, insulation: 2500 VAC, JBUS, Modbus TCP/IP: 10/100 Mbit/s, insulation: 2500 VAC, Ethernet Modbus, TCP/IP daisy chain, BACnet IP communication port protocol |
| 1.1 MB memory capacity, flush mounted |
| IP52 (front) conforming to IEC 60529, IP30 (body) conforming to IEC 60529 IP degree of protection |
| 5 to 95% 122 deg F relative humidity, 2 pollution degree, 9842.52 ft operating altitude |
| -13 to 158 deg F ambient air temperature for operation, -40 to 185 deg F ambient air temperature for storage |
| +/-0.05% frequency, +/-0.2% active energy, +/-1% reactive energy, +/-0.2% active power, +/-0.1% voltage, +/-0.05% power factor, +/-0.15 deg C current |