Square D™ XR Series Surge Protection Device, 120/240 VAC, 25 kA SCCR, 1 Phase
Custom_Product_Images_Illustration
Square D™ XR Series Surge Protection Device, 120/240 VAC, 25 kA SCCR, 1 Phase
SKU529065
MFGR #TVS120XR50S
Your Cost: $375.30/ea
Square D TVS120XR50S SPD 120/240V 50KA 3W+G,1 phase,120/240 V AC,50 kA,NEMA 4X,Nipple,Surge Protection Device,SurgeLogic,UL, CSA
Square D TVS120XR50S SPD 120/240V 50KA 3W+G,1 phase,120/240 V AC,50 kA,NEMA 4X,Nipple,Surge Protection Device,SurgeLogic,UL, CSA
Alternate Catalog Number TVS120XR50S Application Side ARRA Compliant N Buy American Compliant N Catalog Number TVS120XR50S Color Black Connection Wire phase and neutral AWG 12 copper;Wire ground AWG 12 copper Country of Origin US Currency USD Dimensions 3.58 in H x 2.99 in W x 2.68 in D Enclosure NEMA 4X Enclosure Type NEMA 4X EU RoHS Indicator Y Gross Weight Per Pack 1.7400 lb Gross Weight per Pack Metric 789.25 Gross Weight UOM Metric g Harmonization Tariff Schedule Code 8536308000 Height 3.17 in Height [Metric] 8.1280 cm Indicator Type LED Item Group 08463 Length 6.24 in Length [Metric] 16.0020 cm Material Plastic Material Composition Declaration https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=267983375&lang=en-us Mounting NIPPLE Mounting Type Nipple Nominal Discharge Current 10 kA Number of Wires 3 Peak Surge Current 50 kA Returnable N Series XR Series Short Circuit Rating 25 KA kA Size 68 MM,76 MM,91 MM in Standard UL, CSA Standards ARRA, Buy American Act, RoHS Compliant, CSA C22.2 No. 8 1986, UL 1449, California Provision: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Sub Brand SURGELOGIC Substitute Product Catalog Number HEPD50 Type SURGE PROTECTION DEVICE UNSPSC 39121112 UPC 11 78590189712 UPC 12 785901897125 Voltage Rating 120/240 VAC Warranty Description Contractual Warranty:18 months Width 3.86 in Width [Metric] 9.9060 cm Stock Status NONSTOCK Brand Square D™ Manufacturer Schneider Electric Electrical Ratings 120/240 Phase 1 pH Short Circuit Current Rating 25 kA Side 50 KA XR Series SPDsThe XR Series Surge Protective Device (SPD) provides high quality surge protection in a compact and versatile package. This product is ideal for panel builders as well as manufacturers and integrators of instrumentation cabinets for industrial, medical, and commercial applications.The XR uses a hybrid suppression circuit that delivers 40,000 peak amps of surge protection. It also provides sine wave tracking protection and noise filtration. Operation is achieved by incorporating the latest fusing technology. The product is contained in a Type 4x enclosure for maximum flexibility and safety. The XR Series is cUL and UL Listed under UL 1449 (Second Edition dated February 9, 2007).Design Compact design provides easy mounting inside or outside the equipment cabinets. Two types of enclosures are available, with either a side or back direct nippled connector for custom mounting. Green status LEDs provide continuous monitoring of performance. An audible alarm indicates a fault condition.
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Alternate Catalog Number | TVS120XR50S |
Application | Side |
ARRA Compliant | N |
Buy American Compliant | N |
Catalog Number | TVS120XR50S |
Color | Black |
Connection | Wire phase and neutral AWG 12 copper;Wire ground AWG 12 copper |
Country of Origin | US |
Currency | USD |
Dimensions | 3.58 in H x 2.99 in W x 2.68 in D |
Enclosure | NEMA 4X |
Enclosure Type | NEMA 4X |
EU RoHS Indicator | Y |
Gross Weight Per Pack | 1.7400 lb |
Gross Weight per Pack Metric | 789.25 |
Gross Weight UOM Metric | g |
Harmonization Tariff Schedule Code | 8536308000 |
Height | 3.17 in |
Height [Metric] | 8.1280 cm |
Indicator Type | LED |
Item Group | 08463 |
Length | 6.24 in |
Length [Metric] | 16.0020 cm |
Material | Plastic |
Material Composition Declaration | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=267983375&lang=en-us |
Mounting | NIPPLE |
Mounting Type | Nipple |
Nominal Discharge Current | 10 kA |
Number of Wires | 3 |
Peak Surge Current | 50 kA |
Returnable | N |
Series | XR Series |
Short Circuit Rating | 25 KA kA |
Size | 68 MM,76 MM,91 MM in |
Standard | UL, CSA |
Standards | ARRA, Buy American Act, RoHS Compliant, CSA C22.2 No. 8 1986, UL 1449, California Provision: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov |
Sub Brand | SURGELOGIC |
Substitute Product Catalog Number | HEPD50 |
Type | SURGE PROTECTION DEVICE |
UNSPSC | 39121112 |
UPC 11 | 78590189712 |
UPC 12 | 785901897125 |
Voltage Rating | 120/240 VAC |
Warranty Description | Contractual Warranty:18 months |
Width | 3.86 in |
Width [Metric] | 9.9060 cm |
Stock Status | NONSTOCK |
Brand | Square D™ |
Manufacturer | Schneider Electric |
Electrical Ratings | 120/240 |
Phase | 1 pH |
Short Circuit Current Rating | 25 kA |
Side |
50 KA |
XR Series SPDsThe XR Series Surge Protective Device (SPD) provides high quality surge protection in a compact and versatile package. This product is ideal for panel builders as well as manufacturers and integrators of instrumentation cabinets for industrial, medical, and commercial applications.The XR uses a hybrid suppression circuit that delivers 40,000 peak amps of surge protection. It also provides sine wave tracking protection and noise filtration. Operation is achieved by incorporating the latest fusing technology. The product is contained in a Type 4x enclosure for maximum flexibility and safety. The XR Series is cUL and UL Listed under UL 1449 (Second Edition dated February 9, 2007).Design |
Compact design provides easy mounting inside or outside the equipment cabinets. |
Two types of enclosures are available, with either a side or back direct nippled connector for custom mounting. |
Green status LEDs provide continuous monitoring of performance. |
An audible alarm indicates a fault condition. |