or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Telemecanique XMLA004B2S11 XMLA Series Fixed Differential, Pressure Sensor sensing
SKUPDW~13603996
MFGR #XMLA004B2S11
$/ea
Telemecanique XMLA004B2S11, Fixed Differential, XMLA Series, Pressure Sensor Sensing Method, 3 A, Screw Clamp Terminal Connection, 58.02 psi Pressure, 4.45 in H x 1.38 in W x 2.95 in D Size, IP66 Enclosure, -25 to 70 deg C Operating, Environmental Conditions: -40 to 158
Telemecanique XMLA004B2S11, Fixed Differential, XMLA Series, Pressure Sensor Sensing Method, 3 A, Screw Clamp Terminal Connection, 58.02 psi Pressure, 4.45 in H x 1.38 in W x 2.95 in D Size, IP66 Enclosure, -25 to 70 deg C Operating, Environmental Conditions: -40 to 158
Catalog Number XMLA004B2S11 Country of Origin UKN Gross Weight Per Pack 1.5710 lb Height 1.64 Length 4.76 UNSPSC 39122210 Width 3.32 Brand Square D™ Manufacturer Schneider Electric Detection of 1 single threshold;-;Control circuit With local display 6 kV EN/IEC 60947-1 uimp rated impulse withstand voltage Air 32 to 320 deg F (0 to 160 deg C))Fresh water 32 to 320 deg F (0 to 160 deg C))Hydraulic oil 32 to 320 deg F (0 to 160 deg C)) controlled fluid Cable gland 0.35 to 0.51 in (9 to 13 mm) cable entry 5.80 to 582 psi (0.4 to 4 bar) adjustable range of switching point on rising pressure 0.73 to 52.94 psi (05 to 3.65 bar) adjustable range of switching point on falling pressure Diaphragm pressure actuator 58 psi (0.35 bar) +/- 03 bar) natural differential at low setting 58 psi (0.35 bar) +/- 03 bar) natural differential at high setting 300 V UL 508500 V EN/IEC 60947-1300 V CSA C22.2 No 14 ui rated insulation voltage 300 V UL 508500 V EN/IEC 60947-1300 V CSA C22.2 No 14 ui rated insulation voltage Silver contacts contacts material 25 mOhm IEC 255-7 category 325 mOhm NF C 93-050 method A maximum resistance across terminals 10 A cartridge fuse gG (gl) short-circuit protection 8000000 cycles mechanical durability External setting TC standard version protective treatment Any position operating position Class I IEC 1140Class I IEC 536Class I NF C 20-030 electrical shock protection class
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Catalog Number | XMLA004B2S11 |
| Country of Origin | UKN |
| Gross Weight Per Pack | 1.5710 lb |
| Height | 1.64 |
| Length | 4.76 |
| UNSPSC | 39122210 |
| Width | 3.32 |
| Brand | Square D™ |
| Manufacturer | Schneider Electric |
| Detection of 1 single threshold;-;Control circuit |
| With local display |
| 6 kV EN/IEC 60947-1 uimp rated impulse withstand voltage |
| Air 32 to 320 deg F (0 to 160 deg C))Fresh water 32 to 320 deg F (0 to 160 deg C))Hydraulic oil 32 to 320 deg F (0 to 160 deg C)) controlled fluid |
| Cable gland 0.35 to 0.51 in (9 to 13 mm) cable entry |
| 5.80 to 582 psi (0.4 to 4 bar) adjustable range of switching point on rising pressure |
| 0.73 to 52.94 psi (05 to 3.65 bar) adjustable range of switching point on falling pressure |
| Diaphragm pressure actuator |
| 58 psi (0.35 bar) +/- 03 bar) natural differential at low setting |
| 58 psi (0.35 bar) +/- 03 bar) natural differential at high setting |
| 300 V UL 508500 V EN/IEC 60947-1300 V CSA C22.2 No 14 ui rated insulation voltage |
| 300 V UL 508500 V EN/IEC 60947-1300 V CSA C22.2 No 14 ui rated insulation voltage |
| Silver contacts contacts material |
| 25 mOhm IEC 255-7 category 325 mOhm NF C 93-050 method A maximum resistance across terminals |
| 10 A cartridge fuse gG (gl) short-circuit protection |
| 8000000 cycles mechanical durability |
| External setting |
| TC standard version protective treatment |
| Any position operating position |
| Class I IEC 1140Class I IEC 536Class I NF C 20-030 electrical shock protection class |