Schneider Electric Altivar® 212 ATV212HD75N4 3-Phase AC Variable Speed Drive With Heat Sink, 400/480 VAC, 160 A, 100 hp, 12.6 in W x 11.42 in D
Custom_Product_Images_Illustration
Schneider Electric Altivar® 212 ATV212HD75N4 3-Phase AC Variable Speed Drive With Heat Sink, 400/480 VAC, 160 A, 100 hp, 12.6 in W x 11.42 in D
SKU1400580
MFGR #ATV212HD75N4
$/ea
Schneider Electric Altivar® 212 AC Variable Speed Drive, 3-Phase, 400/480 VAC, 160 A, 100 hp, 12.6 in Width, 11.42 in Depth, 24.8 in Height, IP20/IP21/IP41/Open Enclosure, LED Display
Schneider Electric Altivar® 212 AC Variable Speed Drive, 3-Phase, 400/480 VAC, 160 A, 100 hp, 12.6 in Width, 11.42 in Depth, 24.8 in Height, IP20/IP21/IP41/Open Enclosure, LED Display
Alternate Catalog Number ATV212HD75N4 Application Ventilation, Pumping, Air Conditioning and Variable Torque Applications ARRA Compliant N Buy American Compliant N Catalog Number ATV212HD75N4 Country of Origin CN Currency USD Current Rating 160 A 380 V;160 A 460 V Display 1 LED (red) for DC bus energized Display Type LED Enclosure Type IP20/IP21/IP41/Open Environmental Conditions classes 3C1 conforming to IEC 60721-3-3;classes 3S2 conforming to IEC 60721-3-3 EU RoHS Indicator Y Gross Volume Per Pack 13752.90 Gross Volume per Pack Metric 225368.77 Gross Volume UOM CI Gross Volume UOM Metric cm3 Gross Weight Per Pack 0.4350 lb Gross Weight per Pack Metric 43.50 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8504404000 Height 47.0000 in Height [Metric] 47.0000 cm Item Group 22158 Length 77.0000 in Length [Metric] 77.0000 cm Material Composition Declaration https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=61737738&lang=en-us Returnable Y Substitute Product Catalog Number VW3A21212 Type 3-Phase UNSPSC 39122001 Warranty Description Contractual Warranty:18 months Width [Metric] 50.0000 cm Stock Status NONSTOCK Brand Square D™ Manufacturer Schneider Electric Amperage Rating 160 Depth 11.42 Horsepower 100 Voltage Rating 400/480 Width 50.0000 in Ventilation, Pumping, Air Conditioning and Variable Torque Applications VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14;L1/R, L2/S, L3/T terminal 150-150 mm² 300 kcmil);Voltage/frequency ratio, 5 points;voltage/frequency ratio - Energy Saving, quadratic U/f;voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo);voltage/frequency ratio, 2 points;flux vector control without sensor, standard;Overheating protection drive;thermal power stage drive;short-circuit between motor phases drive;input phase breaks drive;overcurrent between output phases and earth drive;overvoltages on the DC bus drive;break on the control circuit drive;against exceeding limit speed drive;line supply overvoltage and undervoltage drive;line supply undervoltage drive;against input phase loss drive;thermal protection motor;motor phase break motor;with PTC probes motor;Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection;internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection 160 A at 380/460 VAC Lower maintenance costs reduce the mechanical stress on belts, piping and ductwork and eliminate valve or inlet guide vane maintenance Reduced harmonics embedded reduced harmonic technology is equivalent to installing a 3% line reactor saving panel space and reducing component and wiring costs Reduce installation costs embedded technology reduces input currents which allows a cost reduction in wire size, short circuit protection devices and enclosure size Improve operating efficiency embedded technology reduces input currents which improves operating efficiency by 10% in many installations Achieve 12 to 24 month payback for AC drives installed on typical pump or fan applications 160 A at 100 hp amperage rating
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Alternate Catalog Number | ATV212HD75N4 |
| Application | Ventilation, Pumping, Air Conditioning and Variable Torque Applications |
| ARRA Compliant | N |
| Buy American Compliant | N |
| Catalog Number | ATV212HD75N4 |
| Country of Origin | CN |
| Currency | USD |
| Current Rating | 160 A 380 V;160 A 460 V |
| Display | 1 LED (red) for DC bus energized |
| Display Type | LED |
| Enclosure Type | IP20/IP21/IP41/Open |
| Environmental Conditions | classes 3C1 conforming to IEC 60721-3-3;classes 3S2 conforming to IEC 60721-3-3 |
| EU RoHS Indicator | Y |
| Gross Volume Per Pack | 13752.90 |
| Gross Volume per Pack Metric | 225368.77 |
| Gross Volume UOM | CI |
| Gross Volume UOM Metric | cm3 |
| Gross Weight Per Pack | 0.4350 lb |
| Gross Weight per Pack Metric | 43.50 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 8504404000 |
| Height | 47.0000 in |
| Height [Metric] | 47.0000 cm |
| Item Group | 22158 |
| Length | 77.0000 in |
| Length [Metric] | 77.0000 cm |
| Material Composition Declaration | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=61737738&lang=en-us |
| Returnable | Y |
| Substitute Product Catalog Number | VW3A21212 |
| Type | 3-Phase |
| UNSPSC | 39122001 |
| Warranty Description | Contractual Warranty:18 months |
| Width [Metric] | 50.0000 cm |
| Stock Status | NONSTOCK |
| Brand | Square D™ |
| Manufacturer | Schneider Electric |
| Amperage Rating | 160 |
| Depth | 11.42 |
| Horsepower | 100 |
| Voltage Rating | 400/480 |
| Width | 50.0000 in |
| Ventilation, Pumping, Air Conditioning and Variable Torque Applications |
| VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14;L1/R, L2/S, L3/T terminal 150-150 mm² 300 kcmil);Voltage/frequency ratio, 5 points;voltage/frequency ratio - Energy Saving, quadratic U/f;voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo);voltage/frequency ratio, 2 points;flux vector control without sensor, standard;Overheating protection drive;thermal power stage drive;short-circuit between motor phases drive;input phase breaks drive;overcurrent between output phases and earth drive;overvoltages on the DC bus drive;break on the control circuit drive;against exceeding limit speed drive;line supply overvoltage and undervoltage drive;line supply undervoltage drive;against input phase loss drive;thermal protection motor;motor phase break motor;with PTC probes motor;Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection;internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection |
| 160 A at 380/460 VAC |
| Lower maintenance costs reduce the mechanical stress on belts, piping and ductwork and eliminate valve or inlet guide vane maintenance |
| Reduced harmonics embedded reduced harmonic technology is equivalent to installing a 3% line reactor saving panel space and reducing component and wiring costs |
| Reduce installation costs embedded technology reduces input currents which allows a cost reduction in wire size, short circuit protection devices and enclosure size |
| Improve operating efficiency embedded technology reduces input currents which improves operating efficiency by 10% in many installations |
| Achieve 12 to 24 month payback for AC drives installed on typical pump or fan applications |
| 160 A at 100 hp amperage rating |