O-Z/Gedney EYAX-75 3/4 IN HOR/VERT SEALING
SKU499371
MFGR #EYAX75
Your Cost: $31.73/ea
OZ-Gedney Type EYAX Vertical/Horizontal Sealing Fitting, Size: 3/4 IN, Malleable Iron, Finish: Zinc Electroplated, Connection: Tapered FNPT, Dimensions: 1-3/4 IN Body Diameter X 4-5/16 IN Overall Length, 1-3/8 IN Turning Radius, 2.25 OZ Sealing Co
OZ-Gedney Type EYAX Vertical/Horizontal Sealing Fitting, Size: 3/4 IN, Malleable Iron, Finish: Zinc Electroplated, Connection: Tapered FNPT, Dimensions: 1-3/4 IN Body Diameter X 4-5/16 IN Overall Length, 1-3/8 IN Turning Radius, 2.25 OZ Sealing Co
Application For Rigid Conduit Or IMC ARRA Compliant N Buy American Compliant N Catalog Number EYAX75 Connection Tapered FNPT Country of Origin MX Currency USD Dimensions 1-3/4 in Dia x 4-5/16 in L EU RoHS Indicator N Gross Weight Per Pack 1.8500 lb Gross Weight per Pack Metric 0.84 Gross Weight UOM Metric kg Height 0.86 in Height [Metric] 21.8440 mm Length 6.80 in Length [Metric] 17.2720 cm Standards UL File No. E34997CSA 009795 for Wet LocationsClass I Division 1/2 Group A/B/C/D, Class I Zone 1/2 Group IIA, IIB and IIC, Class II Division 1/2 Group E/F/G, Class IIIUL 886CSA C22.2 No. 30NEC 500-503/505Mil-F-28675 Type Type EYAX Vertical/Horizontal Sealing Fitting UNSPSC 39121311 UPC 11 78312611393 UPC 12 783126113938 Width 5.20 in Width [Metric] 13.2080 cm Stock Status NONSTOCK Brand O-Z/Gedney Manufacturer O-Z/Gedney Finish Zinc Electroplated Material Malleable Iron Size 3/4 in Suitable For Use With IMC/Rigid Metal Conduit For Rigid Conduit Or IMC To seal vertical or horizontal conduit runs where 40 PCT conductor fill is required; To minimize the passage of gases and vapors and prevent the passage of flames from one portion of the electrical system to another through the conduit; Explosion proof, dust-ignition proof; Use with type EYC sealing compound and type EYF fiber To seal vertical or horizontal conduit runs where 40 PCT conductor fill is required To minimize the passage of gases and vapors and prevent the passage of flames from one portion of the electrical system to another through the conduit Use with type EYC sealing compound and type EYF fiber Prevent passage of gases, vapors or flames from one portion of conduit system to another Restrict any explosion to the sealed off enclosure Prevent pressure piling within conduit system Required in class I, division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures Required in class I, division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps Required in class I, division 1 and 2 locations at the boundary where conduit leaves classified location Required in class I, division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in class I, division 2 locations Smooth, rounded integral bushing in each hub to protect conductor insulation Accurately tapped, tapered threads for tight, rigid joints and ground continuity Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub Allow up to 40% conduit fill in compliance with the national electrical code
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Application | For Rigid Conduit Or IMC |
ARRA Compliant | N |
Buy American Compliant | N |
Catalog Number | EYAX75 |
Connection | Tapered FNPT |
Country of Origin | MX |
Currency | USD |
Dimensions | 1-3/4 in Dia x 4-5/16 in L |
EU RoHS Indicator | N |
Gross Weight Per Pack | 1.8500 lb |
Gross Weight per Pack Metric | 0.84 |
Gross Weight UOM Metric | kg |
Height | 0.86 in |
Height [Metric] | 21.8440 mm |
Length | 6.80 in |
Length [Metric] | 17.2720 cm |
Standards | UL File No. E34997CSA 009795 for Wet LocationsClass I Division 1/2 Group A/B/C/D, Class I Zone 1/2 Group IIA, IIB and IIC, Class II Division 1/2 Group E/F/G, Class IIIUL 886CSA C22.2 No. 30NEC 500-503/505Mil-F-28675 |
Type | Type EYAX Vertical/Horizontal Sealing Fitting |
UNSPSC | 39121311 |
UPC 11 | 78312611393 |
UPC 12 | 783126113938 |
Width | 5.20 in |
Width [Metric] | 13.2080 cm |
Stock Status | NONSTOCK |
Brand | O-Z/Gedney |
Manufacturer | O-Z/Gedney |
Finish | Zinc Electroplated |
Material | Malleable Iron |
Size | 3/4 in |
Suitable For Use With | IMC/Rigid Metal Conduit |
For Rigid Conduit Or IMC |
To seal vertical or horizontal conduit runs where 40 PCT conductor fill is required; To minimize the passage of gases and vapors and prevent the passage of flames from one portion of the electrical system to another through the conduit; Explosion proof, dust-ignition proof; Use with type EYC sealing compound and type EYF fiber |
To seal vertical or horizontal conduit runs where 40 PCT conductor fill is required |
To minimize the passage of gases and vapors and prevent the passage of flames from one portion of the electrical system to another through the conduit |
Use with type EYC sealing compound and type EYF fiber |
Prevent passage of gases, vapors or flames from one portion of conduit system to another |
Restrict any explosion to the sealed off enclosure |
Prevent pressure piling within conduit system |
Required in class I, division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures |
Required in class I, division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps |
Required in class I, division 1 and 2 locations at the boundary where conduit leaves classified location |
Required in class I, division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure |
Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in class I, division 2 locations |
Smooth, rounded integral bushing in each hub to protect conductor insulation |
Accurately tapped, tapered threads for tight, rigid joints and ground continuity |
Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub |
Allow up to 40% conduit fill in compliance with the national electrical code |