AmprobeĀ® ACD-10PLUS ACD-10 PLUS Clamp Multimeter, 600 VAC/VDC, 600 A, 40 MOhm, 40 to 400 Hz, 26 mm Jaw, LCD Display
Custom_Product_Images_Illustration
AmprobeĀ® ACD-10PLUS ACD-10 PLUS Clamp Multimeter, 600 VAC/VDC, 600 A, 40 MOhm, 40 to 400 Hz, 26 mm Jaw, LCD Display
SKU494746
MFGR #ACD-10 PLUS
Your Cost: $148.99/ea
Amprobe?s ACD-10 PLUS meter offers thinner jaws over standard clamp meters. Allowing access to tight measurement areas and still accommodating conductors up to 25 mm. It also measures Capacitance and Frequency. Frequency is measured by either jaws or test leads. Very versatile clamp multimeter.
Amprobe?s ACD-10 PLUS meter offers thinner jaws over standard clamp meters. Allowing access to tight measurement areas and still accommodating conductors up to 25 mm. It also measures Capacitance and Frequency. Frequency is measured by either jaws or test leads. Very versatile clamp multimeter.
AC Current Accuracy +/-1.5% RDG + 8 Digits Catalog Number ACD-10 PLUS Country of Origin TW Counts 4000 Dimensions 7.4 in L x 2.5 in W x 1.3 in H Gross Weight Per Pack 1.0100 lb Operating Temperature 0 to 40 °C Power Source 3 VDC Coin Battery Safety Rating CAT III 600 V Standards RoHS CompliantcULus ListedCE MarkedEN61010-2-032UL61010B-2-032IEC61010-1EN61010-1PROP65: This product is in compliance with PROP65; it is not known to contain any chemicals associated with this regulation Type Digital UNSPSC 41113630 UPC 11 09596941745 UPC 12 09596941745 Voltage Accuracy +/-2% RDG + 5 Digits at 600 VAC, +/-1% RDG + 4 Digits at 600 VDC Stock Status NONSTOCK Brand Fluke® Manufacturer Fluke Corporation Display Type 3-3/4 Digits LCD Electrical Ratings 40 to 600 A, 4 to 600 VAC/VDC, 400 mVDC Frequency Rating 40 to 400 Hz with Jaw, 10 Hz to 100 kHz with Test Leads Jaw Capacity 1 in Resistance 4 to 400 Ohm, 4 to 40 MOhm, 400 uOhm Thin jaws, only 10 mm THK make it easier to maneuver between tightly packed conductors Measures frequency, resistance and capacitance Features continuity beeper to quickly find opens and shorts Accommodates conductors up to 1 in Dia Auto ranging saves time by instantly selecting correct range Auto power off to conserve battery life Rubber over molded case absorbs shock +/-0.8% + 8 digits at 400 Ohm, +/-0.6% + 4 digits at 4 to 400 kOhm, +/-1% + 4 digits at 4 MOhm, +/-2% + 4 digits at 40 MOhm resistance accuracy +/-0.3% + 4 digits at 400 mVDC, +/-0.5% + 3 digits at 4 to 400 VDC, +/-1% + 4 digits at 600 VDC, +/-1.5% + 5 digits at 4 to 400 VAC, +/-2% + 5 digits at 600 VAC for 50 to 500 Hz voltage accuracy AC voltage range - 4 V, 40 V, 400 V with accuracy of +/-( 1.5% + 5 Digit), 600 V with accuracy of +/-( 2% + 5 Digit), CMRR - >60dB at DC to 60 Hz, Rs equal 1 kOhm, maximum crest factor - < 1.75 - 1 at full scale and < 3.5 - 1 at half scale limited to fundamental and harmonics, that fall within the meter specified AC bandwidth for non-sinusoidal waveforms, input impedance - 10 MOhm, 30 pF nominal, transient protection - 6.5 kV (1.2/50us surge), ACD-10 plus - average sensing DC voltage range - 400 mV with accuracy of +/-( 0.3% + 4 Digit), 4 V, 40 V, 400 V with accuracy of +/-( 0.5% + 3 Digit), 600 V with accuracy of +/-( 1% + 4 Digit), NMRR - >50 dB at 50/60 Hz, CMRR - >120 dB at DC, 50/60 Hz, Rs equal 1 kOhm, input impedance - 10 MOhm, 30 pF nominal (1000 MOhm for 400 mV range), transient protection - 6.5 kV (1.2/50 u second surge) Capacitance - 500 nF, 5 F, 50 CF, 500 u F, 3000 u F with accuracy of ( 3.5% + 6 digits) Capacitance - 500 nF, 5 F, 50 CF, 500 u F, 3000 u F with accuracy of ( 3.5% + 6 digits)
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
AC Current Accuracy | +/-1.5% RDG + 8 Digits |
Catalog Number | ACD-10 PLUS |
Country of Origin | TW |
Counts | 4000 |
Dimensions | 7.4 in L x 2.5 in W x 1.3 in H |
Gross Weight Per Pack | 1.0100 lb |
Operating Temperature | 0 to 40 °C |
Power Source | 3 VDC Coin Battery |
Safety Rating | CAT III 600 V |
Standards | RoHS CompliantcULus ListedCE MarkedEN61010-2-032UL61010B-2-032IEC61010-1EN61010-1PROP65: This product is in compliance with PROP65; it is not known to contain any chemicals associated with this regulation |
Type | Digital |
UNSPSC | 41113630 |
UPC 11 | 09596941745 |
UPC 12 | 09596941745 |
Voltage Accuracy | +/-2% RDG + 5 Digits at 600 VAC, +/-1% RDG + 4 Digits at 600 VDC |
Stock Status | NONSTOCK |
Brand | FlukeĀ® |
Manufacturer | Fluke Corporation |
Display Type | 3-3/4 Digits LCD |
Electrical Ratings | 40 to 600 A, 4 to 600 VAC/VDC, 400 mVDC |
Frequency Rating | 40 to 400 Hz with Jaw, 10 Hz to 100 kHz with Test Leads |
Jaw Capacity | 1 in |
Resistance | 4 to 400 Ohm, 4 to 40 MOhm, 400 uOhm |
Thin jaws, only 10 mm THK make it easier to maneuver between tightly packed conductors |
Measures frequency, resistance and capacitance |
Features continuity beeper to quickly find opens and shorts |
Accommodates conductors up to 1 in Dia |
Auto ranging saves time by instantly selecting correct range |
Auto power off to conserve battery life |
Rubber over molded case absorbs shock |
+/-0.8% + 8 digits at 400 Ohm, +/-0.6% + 4 digits at 4 to 400 kOhm, +/-1% + 4 digits at 4 MOhm, +/-2% + 4 digits at 40 MOhm resistance accuracy |
+/-0.3% + 4 digits at 400 mVDC, +/-0.5% + 3 digits at 4 to 400 VDC, +/-1% + 4 digits at 600 VDC, +/-1.5% + 5 digits at 4 to 400 VAC, +/-2% + 5 digits at 600 VAC for 50 to 500 Hz voltage accuracy |
AC voltage range - 4 V, 40 V, 400 V with accuracy of +/-( 1.5% + 5 Digit), 600 V with accuracy of +/-( 2% + 5 Digit), CMRR - >60dB at DC to 60 Hz, Rs equal 1 kOhm, maximum crest factor - < 1.75 - 1 at full scale and < 3.5 - 1 at half scale limited to fundamental and harmonics, that fall within the meter specified AC bandwidth for non-sinusoidal waveforms, input impedance - 10 MOhm, 30 pF nominal, transient protection - 6.5 kV (1.2/50us surge), ACD-10 plus - average sensing |
DC voltage range - 400 mV with accuracy of +/-( 0.3% + 4 Digit), 4 V, 40 V, 400 V with accuracy of +/-( 0.5% + 3 Digit), 600 V with accuracy of +/-( 1% + 4 Digit), NMRR - >50 dB at 50/60 Hz, CMRR - >120 dB at DC, 50/60 Hz, Rs equal 1 kOhm, input impedance - 10 MOhm, 30 pF nominal (1000 MOhm for 400 mV range), transient protection - 6.5 kV (1.2/50 u second surge) |
Capacitance - 500 nF, 5 F, 50 CF, 500 u F, 3000 u F with accuracy of ( 3.5% + 6 digits) |
Capacitance - 500 nF, 5 F, 50 CF, 500 u F, 3000 u F with accuracy of ( 3.5% + 6 digits) |