or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Schneider Electric LAL36125 Adjustable Standard Interrupt Molded Case Circuit Breaker, 600 VAC/250 VDC, 125 A, 3 Poles
Custom_Product_Images_Illustration
Schneider Electric LAL36125 Adjustable Standard Interrupt Molded Case Circuit Breaker, 600 VAC/250 VDC, 125 A, 3 Poles
SKU312844
MFGR #LAL36125
$/ea
Schneider Electric LAL36125 MOLDED CASE CIRCUIT BREAKER 600V 125A,125 A,125 A,625...1250 A,22 kA at 600 V AC-10 kA at 125 V DC-42 kA at 240 V AC-30 kA at 480 V AC-10 kA at 250 V DC,250 V DC-600 V AC,250 V DC-600 V AC,circuit breaker,unit mount
Schneider Electric LAL36125 MOLDED CASE CIRCUIT BREAKER 600V 125A,125 A,125 A,625...1250 A,22 kA at 600 V AC-10 kA at 125 V DC-42 kA at 240 V AC-30 kA at 480 V AC-10 kA at 250 V DC,250 V DC-600 V AC,250 V DC-600 V AC,circuit breaker,unit mount
Actuator Type Rotary Handle Alternate Catalog Number LAL36125 ARRA Compliant N Buy American Compliant N Catalog Number LAL36125 Connection AWG 1...600 KCMIL ALUMINIUM/COPPER)1 -AWG 1...250 KCMIL ALUMINIUM/COPPER)2,LUGS LOAD-LUGS LINE Connection Type Line/Load Lug Country of Origin MX Currency USD Dimensions 11 in H x 6 in W x 5.84 in D Enclosure Type NEMA 1/3R/12/4/4X/5 EU RoHS Indicator Y Frame LA Series Frequency Rating 50/60 Hz Gross Weight Per Pack 0.0722 lb Gross Weight per Pack Metric 7.21 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536200020 Height 21.4330 in Height [Metric] 21.4330 cm Item Group 00935 Length 43.4980 in Length [Metric] 43.4980 cm Material Composition Declaration https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=428011&lang=en-us Mounting Type Unit Number Of Poles 3 Phase 3 pH Returnable Y Standard IEC-CSA-UL LISTED Standards ARRA CompliantBuy American Act CompliantRoHS CompliantUL 489 File No. E10027CSA C22.2 No. 5-02 File No. LR40970CCC/CE MarkedNMX J-266Federal Specification W-C-375B/GENIEC 60947-2NEMA AB1NOMeccn: EAR99 Temperature Rating 104 °F Trip Range 625 to 1250 A Type Adjustable Standard Interrupt UNSPSC 39121601 UPC 11 78590184840 UPC 12 785901848400 Warranty Description Contractual Warranty:18 months Width 28.2580 in Width [Metric] 28.2580 cm Wire Size (1) 1 AWG to 600 kcmil/(2)1 AWG to 250 kcmil Al/Cu Stock Status NONSTOCK Brand Square D⢠Manufacturer Schneider Electric Amperage Rating 125 A Interrupt Rating 42 kA at 240 VAC/30 kA at 480 VAC/22 kA at 600 VAC/10 kA at 125/250 VDC Trip Type Thermal-magnetic Voltage Rating 600 VAC/250 VDC UNIT MOUNT Common accessories and auxiliaries with other PowerPact⢠frames Common accessories across the range of PowerPact⢠molded case circuit breakers allow users to make late specification changes A wide range of field installable accessories allows customers to reduce inventory without sacrificing flexibility Broad offering of operating mechanisms and ratings specifically designed to be used as the main panel disconnect for control panel applications IEC style rotary operating handles Equipped with a unique terminal design that makes converting between busbar and lug options easy Easy to install, extremely versatile, a wide variety of terminal options include mechanical lugs, crimp lugs, power distribution lugs and lug shields 42 kA at 240 VAC, 30 kA at 480 VAC, 22 kA at 600 VAC, 10 kA at 125 VDC, 10 kA at 250 VDC interrupt rating
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
| Actuator Type | Rotary Handle |
| Alternate Catalog Number | LAL36125 |
| ARRA Compliant | N |
| Buy American Compliant | N |
| Catalog Number | LAL36125 |
| Connection | AWG 1...600 KCMIL ALUMINIUM/COPPER)1 -AWG 1...250 KCMIL ALUMINIUM/COPPER)2,LUGS LOAD-LUGS LINE |
| Connection Type | Line/Load Lug |
| Country of Origin | MX |
| Currency | USD |
| Dimensions | 11 in H x 6 in W x 5.84 in D |
| Enclosure Type | NEMA 1/3R/12/4/4X/5 |
| EU RoHS Indicator | Y |
| Frame | LA Series |
| Frequency Rating | 50/60 Hz |
| Gross Weight Per Pack | 0.0722 lb |
| Gross Weight per Pack Metric | 7.21 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 8536200020 |
| Height | 21.4330 in |
| Height [Metric] | 21.4330 cm |
| Item Group | 00935 |
| Length | 43.4980 in |
| Length [Metric] | 43.4980 cm |
| Material Composition Declaration | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=428011&lang=en-us |
| Mounting Type | Unit |
| Number Of Poles | 3 |
| Phase | 3 pH |
| Returnable | Y |
| Standard | IEC-CSA-UL LISTED |
| Standards | ARRA CompliantBuy American Act CompliantRoHS CompliantUL 489 File No. E10027CSA C22.2 No. 5-02 File No. LR40970CCC/CE MarkedNMX J-266Federal Specification W-C-375B/GENIEC 60947-2NEMA AB1NOMeccn: EAR99 |
| Temperature Rating | 104 °F |
| Trip Range | 625 to 1250 A |
| Type | Adjustable Standard Interrupt |
| UNSPSC | 39121601 |
| UPC 11 | 78590184840 |
| UPC 12 | 785901848400 |
| Warranty Description | Contractual Warranty:18 months |
| Width | 28.2580 in |
| Width [Metric] | 28.2580 cm |
| Wire Size | (1) 1 AWG to 600 kcmil/(2)1 AWG to 250 kcmil Al/Cu |
| Stock Status | NONSTOCK |
| Brand | Square D⢠|
| Manufacturer | Schneider Electric |
| Amperage Rating | 125 A |
| Interrupt Rating | 42 kA at 240 VAC/30 kA at 480 VAC/22 kA at 600 VAC/10 kA at 125/250 VDC |
| Trip Type | Thermal-magnetic |
| Voltage Rating | 600 VAC/250 VDC |
| UNIT MOUNT |
| Common accessories and auxiliaries with other PowerPact⢠frames |
| Common accessories across the range of PowerPact⢠molded case circuit breakers allow users to make late specification changes |
| A wide range of field installable accessories allows customers to reduce inventory without sacrificing flexibility |
| Broad offering of operating mechanisms and ratings specifically designed to be used as the main panel disconnect for control panel applications |
| IEC style rotary operating handles |
| Equipped with a unique terminal design that makes converting between busbar and lug options easy |
| Easy to install, extremely versatile, a wide variety of terminal options include mechanical lugs, crimp lugs, power distribution lugs and lug shields |
| 42 kA at 240 VAC, 30 kA at 480 VAC, 22 kA at 600 VAC, 10 kA at 125 VDC, 10 kA at 250 VDC interrupt rating |