or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Square D™
Schneider Electric ClimaSys CV NSYCVF38M115PF Self-Extinguishing Forced Ventilation Fan, 115 VAC, 0.16 A, 3.3/3.5 W Power Rating, 38 cu-m/hr Air Flow, IP54 Enclosure
Custom_Product_Images_Illustration
Square D™
Schneider Electric ClimaSys CV NSYCVF38M115PF Self-Extinguishing Forced Ventilation Fan, 115 VAC, 0.16 A, 3.3/3.5 W Power Rating, 38 cu-m/hr Air Flow, IP54 Enclosure
SKUPDW~7520899
MFGR #NSYCVF38M115PF
Price Not Available
Schneider Electric ClimaSys CV Forced Ventilation Fan, Self-Extinguishing, 115 VAC, 0.16 A, 3.3/3.5 W Power, 40 to 41 dB Sound Level, 38 cu-m/hr Air Flow, Axial Motor, Injected Thermoplastic (ASA PC) Grille, IP54 Enclosure, 5.39 in H x 4.61 in W x 1.93 in D Dimensions
Schneider Electric ClimaSys CV Forced Ventilation Fan, Self-Extinguishing, 115 VAC, 0.16 A, 3.3/3.5 W Power, 40 to 41 dB Sound Level, 38 cu-m/hr Air Flow, Axial Motor, Injected Thermoplastic (ASA PC) Grille, IP54 Enclosure, 5.39 in H x 4.61 in W x 1.93 in D Dimensions
Alternate Catalog Number NSYCVF38M115PF Application FORCED VENTILATION 38 M¦/H ARRA Compliant N Buy American Compliant N Catalog Number NSYCVF38M115PF Color Outlet grille Gray RAL 7035) Consist Of 1 axial motor;2 protective grille on the front and rear surfaces;1 filter front of axial motor;1 outlet grille front;1 cut-out template Country of Origin FR Currency USD Depth External : 49 mm Dimensions 5.39 in H x 4.61 in W x 1.93 in D EU RoHS Indicator Y Grille Material Injected Thermoplastic (ASA PC) Gross Volume Per Pack 59.18 Gross Volume per Pack Metric 969.78 Gross Volume UOM CI Gross Volume UOM Metric cm3 Gross Weight Per Pack 3.0000 lb Gross Weight per Pack Metric 292.00 Gross Weight UOM Metric g Harmonization Tariff Schedule Code 8414596590 Height 7.5000 in Height [Metric] 7.0000 cm Item Group 80036 Length 14.5000 in Length [Metric] 15.0000 cm Material Outlet grille injected thermoplastic (ASA PC) Material Composition Declaration https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=10178360&lang=en-us Motor Type Axial Returnable Y Size EXTERNAL 117 MM,EXTERNAL 137 MM,EXTERNAL 49 MM Sound Level 40 to 41 Standard IP54 Sub Brand CLIMASYS CV Type Self-Extinguishing UNSPSC 39121321 UPC 11 78590169852 UPC 12 785901698524 Warranty Description Contractual Warranty:18 months Width 12.5000 in Width [Metric] 12.5000 cm Brand Square D™ Manufacturer Schneider Electric Amperage Rating 0.16 Enclosure Type IP54 Power Rating 3.3/3.5 Voltage Rating 115 FORCED VENTILATION 38 M¦/H Cable The ClimaSys CV is recommended for installations in which the ambient temperature is lower than the desired temperature inside the enclosure The fans comprise an axial motor, a protective housing on the front and rear surfaces and a filter designed to retain dust particles Filter can be replaced during operation without risk of contact with the rotating element The outside temperature must be 5 deg C lower than the desired temperature inside the enclosure The filters that equipped the fans must be cleaned and replaced regularly The surrounding environment must be relatively clean and over frequent filter replacement should be avoided Bear in mind the pressure losses caused by the outlet element (grille with filter, ventilation louvre or simple opening) when determining the fan flow rate -40 to 70 deg C storage temperature The cut-out template supplied with the device avoids the need for marking and protects the surface of the enclosure during handling 3.3 W at 50 Hz, 3.5 W at 60 Hz power rating 3.3 W at 50 Hz, 3.5 W at 60 Hz power rating 0.16 A at 50/60 Hz current rating
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Alternate Catalog Number | NSYCVF38M115PF |
| Application | FORCED VENTILATION 38 M¦/H |
| ARRA Compliant | N |
| Buy American Compliant | N |
| Catalog Number | NSYCVF38M115PF |
| Color | Outlet grille Gray RAL 7035) |
| Consist Of | 1 axial motor;2 protective grille on the front and rear surfaces;1 filter front of axial motor;1 outlet grille front;1 cut-out template |
| Country of Origin | FR |
| Currency | USD |
| Depth | External : 49 mm |
| Dimensions | 5.39 in H x 4.61 in W x 1.93 in D |
| EU RoHS Indicator | Y |
| Grille Material | Injected Thermoplastic (ASA PC) |
| Gross Volume Per Pack | 59.18 |
| Gross Volume per Pack Metric | 969.78 |
| Gross Volume UOM | CI |
| Gross Volume UOM Metric | cm3 |
| Gross Weight Per Pack | 3.0000 lb |
| Gross Weight per Pack Metric | 292.00 |
| Gross Weight UOM Metric | g |
| Harmonization Tariff Schedule Code | 8414596590 |
| Height | 7.5000 in |
| Height [Metric] | 7.0000 cm |
| Item Group | 80036 |
| Length | 14.5000 in |
| Length [Metric] | 15.0000 cm |
| Material | Outlet grille injected thermoplastic (ASA PC) |
| Material Composition Declaration | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=10178360&lang=en-us |
| Motor Type | Axial |
| Returnable | Y |
| Size | EXTERNAL 117 MM,EXTERNAL 137 MM,EXTERNAL 49 MM |
| Sound Level | 40 to 41 |
| Standard | IP54 |
| Sub Brand | CLIMASYS CV |
| Type | Self-Extinguishing |
| UNSPSC | 39121321 |
| UPC 11 | 78590169852 |
| UPC 12 | 785901698524 |
| Warranty Description | Contractual Warranty:18 months |
| Width | 12.5000 in |
| Width [Metric] | 12.5000 cm |
| Brand | Square D™ |
| Manufacturer | Schneider Electric |
| Amperage Rating | 0.16 |
| Enclosure Type | IP54 |
| Power Rating | 3.3/3.5 |
| Voltage Rating | 115 |
| FORCED VENTILATION 38 M¦/H |
| Cable |
| The ClimaSys CV is recommended for installations in which the ambient temperature is lower than the desired temperature inside the enclosure |
| The fans comprise an axial motor, a protective housing on the front and rear surfaces and a filter designed to retain dust particles |
| Filter can be replaced during operation without risk of contact with the rotating element |
| The outside temperature must be 5 deg C lower than the desired temperature inside the enclosure |
| The filters that equipped the fans must be cleaned and replaced regularly |
| The surrounding environment must be relatively clean and over frequent filter replacement should be avoided |
| Bear in mind the pressure losses caused by the outlet element (grille with filter, ventilation louvre or simple opening) when determining the fan flow rate |
| -40 to 70 deg C storage temperature |
| The cut-out template supplied with the device avoids the need for marking and protects the surface of the enclosure during handling |
| 3.3 W at 50 Hz, 3.5 W at 60 Hz power rating |
| 3.3 W at 50 Hz, 3.5 W at 60 Hz power rating |
| 0.16 A at 50/60 Hz current rating |