• Applications
  • Features
Ventilation, Pumping, Air Conditioning, Asynchronous Motor and Fans in HVAC Applications
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES TERMINAL 2.5-2.5 MMA² / AWG 14-L1/R, L2/S, L3/T TERMINAL 6-6 MMA² / AWG 10,ADJUSTABLE PI REGULATOR,INTERNAL SUPPLY FOR REFERENCE POTENTIOMETER (1 TO 10 KOHM) 10.5 V DC +/- 5 , <10 A OVERLOAD AND SHORT-CIRCUIT PROTECTION-INTERNAL SUPPLY 24 V DC 21-27 V), <200 A OVERLOAD AND SHORT-CIRCUIT PROTECTION,OVERHEATING PROTECTION DRIVE-LINE SUPPLY UNDERVOLTAGE DRIVE-AGAINST INPUT PHASE LOSS DRIVE-THERMAL PROTECTION MOTOR-MOTOR PHASE BREAK MOTOR-WITH PTC PROBES MOTOR-THERMAL POWER STAGE DRIVE-SHORT-CIRCUIT BETWEEN MOTOR PHASES DRIVE-INPUT PHASE BREAKS DRIVE-OVERCURRENT BETWEEN OUTPUT PHASES AND EARTH DRIVE-OVERVOLTAGES ON THE DC BUS DRIVE-BREAK ON THE CONTROL CIRCUIT DRIVE-AGAINST EXCEEDING LIMIT SPEED DRIVE-LINE SUPPLY OVERVOLTAGE AND UNDERVOLTAGE DRIVE,VOLTAGE/FREQUENCY RATIO, 2 POINTS-VOLTAGE/FREQUENCY RATIO, 5 POINTS-FLUX VECTOR CONTROL WITHOUT SENSOR, STANDARD-VOLTAGE/FREQUENCY RATIO, AUTOMATIC IR COMPENSATION (U/F + AUTOMATIC UO)-VOLTAGE/FREQUENCY RATIO - ENERGY SAVING, QUADRATIC U/F
17.5 A at 230 VAC
Lower maintenance costs reduce the mechanical stress on belts, piping and ductwork and eliminate valve or inlet guide vane maintenance
Reduced harmonics embedded reduced harmonic technology is equivalent to installing a 3% line reactor saving panel space and reducing component and wiring costs
Reduce installation costs embedded technology reduces input currents which allows a cost reduction in wire size, short circuit protection devices and enclosure size
Improve operating efficiency embedded technology reduces input currents which improves operating efficiency by 10% in many installations
Achieve 12 to 24 month payback for AC drives installed on typical pump or fan applications
2.5 sq-mm/14 AWG VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal, 6 sq-mm/10 AWG L1/R, L2/S, L3/T terminal
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 VDC +/- 5 %, <10 A overload and short circuit protection, internal supply 24 VDC 21 to 27 V, <200 A overload and short circuit protection
Overheating protection drive, thermal power stage drive, short circuit between motor phases drive, input phase breaks drive, overcurrent between output phases and earth drive, overvoltage on the DC bus drive, break on the control circuit drive, against exceeding limit speed drive, line supply overvoltage and undervoltage drive, line supply undervoltage drive