Schneider Electric 9001KR16H2 Harmony™ 9001K Non-Illuminated Pushbutton, 30 mm, 2NO/2NC, Trigger Action Operator, Red
Pilot Devices
520103
MFG #: 9001KR16H2
Square D™
198.69000
/ ea
Schneider Electric 9001KR16H2 30mm TTR Mushroom, 2 C/O,10A,2 NO - 2 NC,30mm Round,600V,Harmony,Maintained - Trigger Action - Turn-to-Release,NEMA 1/2/3/3R/4/6/12/13,Panel,Pushbutton,Red,Screw Clamp,Screw-On Plastic Mushroom (41mm),UL File Number E42259 CCN NKCR - CSA File Number LR24590 Class 3211-03 - CE Marked,Water tight, Dust tight and Oil tight (Indoor/Outdoor)
- 360 Degree View URL - index.html?pid=11003&id=10866461360Den&ext=webp(360 Degree View URL)
- Brochure URL - 11003_8QOJYL9EPK6C5SGW.pdf(Brochure URL)
- Catalog URL - IDW_DOCUMENT_12298800a20ab14d251012dfd03b272c64e6f12448248e11314caf8654fb215f.pdf(Catalog URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=9001KR16H2_2D.dwg(Computer~Aided [CAD|BIM] Model URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Spec Sheet URL - 11003_YCV81O9TJFS7ZNK6.pdf(Spec Sheet URL)
- Tech Bulletin URL - 11003_YV8CSDN3W5BOTJLA.pdf(Tech Bulletin URL)
- Tech Drawing URL - a5cdb93f97ea633be51099ed5d9eccc10ae69741.pdf(Tech Drawing URL)
- Video - https://www.youtube.com/embed/z4UUZQz35-w(Video)
- Features
CHROMIUM PLATED METAL,EMERGENCY STOP PUSH-BUTTON |
Red mushroom 40 mm Dia unmarked operator profile |
40 mm H x 40 mm W x 116 mm D |
Round shape of signaling unit head |
Any operating position |
0.8 N-m conforming to IEC 60947-1 tightening torque |
Cross slotted head shape of screw head |
5000000 cycles mechanical durability |
3 A 240 VAC-15 A600-Q600 NEMA and 0.55 A 125 VDC-13 A600-Q600 NEMA rated operational current |
250 VAC conforming to IEC 60947-1 rated insulation voltage |
2.5 kV conforming to IEC 60947-1 rated impulse withstand voltage |
3 degree of pollution |
Silver alloy (AgNi) contact material |
<= 0.1 kA at 600 VDC-13, <=1 2 kA at 120 VAC-15, 7200 VA, <= 0.27 kA at 250 VDC-13 and <= 0.55 kA at 125 VDC-13 rated short circuit making capacity |
<= 3 kA at 240 VAC-15, 720 VA, <= 6 kA at 120 VAC-15, 720 VA, <= 0.1 kA at 600 VDC-13, <= 0.27 kA at 250 VDC-13, <= 0.55 kA at 125 VDC-13, <= 1.2 kA at 600 VAC-15, 720 VA and <= 1.5 kA at 480 VAC-15, 720 VA rated breaking capacity |
TC protective treatment |
7 gn (2 to 500 Hz) conforming to IEC 60068-2-6 vibration resistance |
50 gn conforming to IEC 60068-2-27 shock resistance |
Class II conforming to IEC 61140 electrical shock protection class |
Watertight, dusttight and oiltight (indoor/outdoor) environmental conditions |