O-Z/Gedney T75ACG T-75ACG Type T Conduit Body With Cover and Gasket, 3/4 in Hub, 7.1 cu-in, Aluminum, Enamel Coated
Custom_Product_Images_Illustration
O-Z/Gedney T75ACG T-75ACG Type T Conduit Body With Cover and Gasket, 3/4 in Hub, 7.1 cu-in, Aluminum, Enamel Coated
SKU235513
MFGR #T75ACG
Your Cost: $47.49/ea
O-Z/Gedney conduit bodies, covers and gaskets provide access to conductors for pulling, splicing, maintenance, and future changes and upgrades. They allow connection of straight conduit runs, branch conduit runs and 90deg bends. Covers and gaskets can be ordered separately, or the conduit bodies, covers and gaskets can be ordered as a complete assembly.
O-Z/Gedney conduit bodies, covers and gaskets provide access to conductors for pulling, splicing, maintenance, and future changes and upgrades. They allow connection of straight conduit runs, branch conduit runs and 90deg bends. Covers and gaskets can be ordered separately, or the conduit bodies, covers and gaskets can be ordered as a complete assembly.
Application For Rigid Conduit And IMC ARRA Compliant N Buy American Compliant N Catalog Number T75ACG Connection Tapered FNPT Connection Type Tapered FNPT Country of Origin IN Currency USD Dimensions 5-5/8 in L x 1-5/8 in H Enclosure NEMA FB-1/FB-2.10 EU RoHS Indicator N Gross Weight Per Pack 0.5200 lb Gross Weight per Pack Metric 0.24 Gross Weight UOM Metric kg Height 0.92 in Height [Metric] 23.3680 mm Length 8.70 in Length [Metric] 22.0980 cm Number of Hubs 3 Standard Third Party Certification: UL File Number E-18095, CSA LR-9795, Applicable Third Party Standards: UL 514A, CSA C22.2 No.18, Federal Specification Number A-A-50563; NEMA : FB-1, FB-2.10 Standards UL 514A File No. E18095C22.2 No. 18/009795 CertifiedFederal Specification A-A-50563Hazardous Locations Class 1, Div 2 Per NEC Section 501-4(B) Type Type T Conduit Body, Cover And Gasket Assembly UNSPSC 39131708 UPC 11 78312606466 UPC 12 783126064667 Width 6.80 in Width [Metric] 17.2720 cm Stock Status NONSTOCK Brand O-Z/Gedney Manufacturer O-Z/Gedney Capacity 7.1 in³ Finish Aluminum Hub Size 0.75 in Material Conduit Body: Die-Cast, Copper-Free Aluminum, Cover: Type BS Aluminum, Gasket: Type SGN Neoprene For Rigid Conduit And IMC Serve as pulling fittings; Make bends in conduit system; Provide openings for splicing; Connect and change direction of conduit runs; Allow connections for branch runs; Permit access to conductors for maintenance; Closed-cell neoprene gasket; Tapered threaded hubs (NPT); Threaded style is raintight when used with casketed covers; Internal volume and maximum wire capacity clearly marked on castings; Suitable for wet locations Tapered threaded hubs (NPT) Raintight when used with gasketed covers Internal volume and maximum wire capacity clearly marked on castings Suitable for wet locations when used with gasketed covers Allow connections for branch runs Permit access to conductors for maintenance Closed-cell neoprene gasket Tapered threaded hubs (NPT) Threaded style is raintight when used with casketed covers Internal volume and maximum wire capacity clearly marked on castings Suitable for wet locations To provide access to conductors for pulling, splicing, maintenance and future changes/upgrades, allows connection of straight conduit runs, branch conduit runs and 90 deg bends Type BS aluminum cover, Type SGN neoprene gasket Die Cast Copper Free Aluminum
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Application | For Rigid Conduit And IMC |
| ARRA Compliant | N |
| Buy American Compliant | N |
| Catalog Number | T75ACG |
| Connection | Tapered FNPT |
| Connection Type | Tapered FNPT |
| Country of Origin | IN |
| Currency | USD |
| Dimensions | 5-5/8 in L x 1-5/8 in H |
| Enclosure | NEMA FB-1/FB-2.10 |
| EU RoHS Indicator | N |
| Gross Weight Per Pack | 0.5200 lb |
| Gross Weight per Pack Metric | 0.24 |
| Gross Weight UOM Metric | kg |
| Height | 0.92 in |
| Height [Metric] | 23.3680 mm |
| Length | 8.70 in |
| Length [Metric] | 22.0980 cm |
| Number of Hubs | 3 |
| Standard | Third Party Certification: UL File Number E-18095, CSA LR-9795, Applicable Third Party Standards: UL 514A, CSA C22.2 No.18, Federal Specification Number A-A-50563; NEMA : FB-1, FB-2.10 |
| Standards | UL 514A File No. E18095C22.2 No. 18/009795 CertifiedFederal Specification A-A-50563Hazardous Locations Class 1, Div 2 Per NEC Section 501-4(B) |
| Type | Type T Conduit Body, Cover And Gasket Assembly |
| UNSPSC | 39131708 |
| UPC 11 | 78312606466 |
| UPC 12 | 783126064667 |
| Width | 6.80 in |
| Width [Metric] | 17.2720 cm |
| Stock Status | NONSTOCK |
| Brand | O-Z/Gedney |
| Manufacturer | O-Z/Gedney |
| Capacity | 7.1 in³ |
| Finish | Aluminum |
| Hub Size | 0.75 in |
| Material | Conduit Body: Die-Cast, Copper-Free Aluminum, Cover: Type BS Aluminum, Gasket: Type SGN Neoprene |
| For Rigid Conduit And IMC |
| Serve as pulling fittings; Make bends in conduit system; Provide openings for splicing; Connect and change direction of conduit runs; Allow connections for branch runs; Permit access to conductors for maintenance; Closed-cell neoprene gasket; Tapered threaded hubs (NPT); Threaded style is raintight when used with casketed covers; Internal volume and maximum wire capacity clearly marked on castings; Suitable for wet locations |
| Tapered threaded hubs (NPT) |
| Raintight when used with gasketed covers |
| Internal volume and maximum wire capacity clearly marked on castings |
| Suitable for wet locations when used with gasketed covers |
| Allow connections for branch runs |
| Permit access to conductors for maintenance |
| Closed-cell neoprene gasket |
| Tapered threaded hubs (NPT) |
| Threaded style is raintight when used with casketed covers |
| Internal volume and maximum wire capacity clearly marked on castings |
| Suitable for wet locations |
| To provide access to conductors for pulling, splicing, maintenance and future changes/upgrades, allows connection of straight conduit runs, branch conduit runs and 90 deg bends |
| Type BS aluminum cover, Type SGN neoprene gasket |
| Die Cast Copper Free Aluminum |