or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Fluke® FLUKE-1555/KIT Insulation Tester Kit, 1000 V, 2 mA, 50/60 Hz, 200 kOhm to 2 TOhm, 5 Pieces
Custom_Product_Images_Illustration
Fluke® FLUKE-1555/KIT Insulation Tester Kit, 1000 V, 2 mA, 50/60 Hz, 200 kOhm to 2 TOhm, 5 Pieces
SKU717208
MFGR #FLUKE-1555/KIT
Your Cost: $7,831.99/ea
List: Fluke insulation testers can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class, 3 year warranty and CAT IV 600 V safety rating. With measurement storage and PC interface, the 1555 is the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur.
Fluke insulation testers can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class, 3 year warranty and CAT IV 600 V safety rating. With measurement storage and PC interface, the 1555 is the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur.
Alternate Catalog Number 3665111 Amperage Rating 2m A Application For Capturing And Trending anomalies for troubleshooting, commissioning and preventative maintenance of insulation resistance ARRA Compliant C Buy American Compliant C Catalog Number FLUKE-1555/KIT Country of Origin US Currency USD Dimensions 269 MM Length X 277 MM Width X 160 MM Height Display 75 MM Height X 105 MM Width LCD Enclosure IP40 EU RoHS Indicator U Frequency Response 50/60 Hz Gross Weight Per Pack 7.9400 lb Gross Weight per Pack Metric 3.60 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 9030310000 Height 6.70 in Height [Metric] 17.0180 cm Interface Type PC Port Length 13.00 in Length [Metric] 33.0200 cm Resistance Range 200 KOHM - 2 TOHM Standard CSA, CE Certified, EN 61326, IEC 61010-1: Overvoltage category II, Pollution Degree 2, IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT IIIIEC 61557-1, IEC 61557-2, C/UL Listed Standards CE Certified, CSA Certified, TUV, N10140 Registered, IEC 61010-2-030- Measurement 600V CAT IV / 1000V CAT IIIIEC 61557-1, IEC 61557-2, C/UL Listed Type Insulation Tester Kit UNSPSC 41113624 UPC 11 09596955097 UPC 12 095969550970 Width 9.50 in Width [Metric] 24.1300 cm Stock Status NONSTOCK Brand Fluke® Manufacturer Fluke Corporation Voltage Rating 250/500/1,000/2,500/5,000/10,000 V For Capturing And Trending anomalies for troubleshooting, commissioning and preventative maintenance of insulation resistance Test voltages to up 10 KV and save time by trending on the spot only with fluke Connect; Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety, selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V; Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall, long battery life gives the user over 750 tests between chargesAutomatic calculation of dielectric Absorption (DAR) and polarization Index (PI) with no additional setup, guard system eliminates the effect of surface leakage current on high-resistance measurements, large digital/analog LCD for easy viewing, capacitance and leakage current measurement, ramp function for breakdown testing; Resistance measurements up to 2 TOHM, timer settings up to 99 MINT for timed tests Test voltages to up 10 kV and save time by trending on the spot only with fluke connect Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 VAC/ VDC for increased user safety, selectable test voltages in 50 V steps from 250 - 1000 V, and 100 V steps above 1000 V Long battery life gives the user over 750 tests between charges Automatic calculation of dielectric absorption (DAR) and polarization index (PI) with no additional setup Ramp function for breakdown testing Timer settings up to 99 minutes for timed tests Guard system eliminates the effect of surface leakage current on high-resistance measurements Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall 75 x 105 mm LCD, Digital LCD/analog display 2 deg pollution, -20 to 50 deg C temperature rating, IP rating IP40 5 - 20% accuracy PC port interface Hardplastic enclosure Voltage rating - 250, 500, 1000, 2500, 5000, 10000 V
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Alternate Catalog Number | 3665111 |
Amperage Rating | 2m A |
Application | For Capturing And Trending anomalies for troubleshooting, commissioning and preventative maintenance of insulation resistance |
ARRA Compliant | C |
Buy American Compliant | C |
Catalog Number | FLUKE-1555/KIT |
Country of Origin | US |
Currency | USD |
Dimensions | 269 MM Length X 277 MM Width X 160 MM Height |
Display | 75 MM Height X 105 MM Width LCD |
Enclosure | IP40 |
EU RoHS Indicator | U |
Frequency Response | 50/60 Hz |
Gross Weight Per Pack | 7.9400 lb |
Gross Weight per Pack Metric | 3.60 |
Gross Weight UOM Metric | kg |
Harmonization Tariff Schedule Code | 9030310000 |
Height | 6.70 in |
Height [Metric] | 17.0180 cm |
Interface Type | PC Port |
Length | 13.00 in |
Length [Metric] | 33.0200 cm |
Resistance Range | 200 KOHM - 2 TOHM |
Standard | CSA, CE Certified, EN 61326, IEC 61010-1: Overvoltage category II, Pollution Degree 2, IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT IIIIEC 61557-1, IEC 61557-2, C/UL Listed |
Standards | CE Certified, CSA Certified, TUV, N10140 Registered, IEC 61010-2-030- Measurement 600V CAT IV / 1000V CAT IIIIEC 61557-1, IEC 61557-2, C/UL Listed |
Type | Insulation Tester Kit |
UNSPSC | 41113624 |
UPC 11 | 09596955097 |
UPC 12 | 095969550970 |
Width | 9.50 in |
Width [Metric] | 24.1300 cm |
Stock Status | NONSTOCK |
Brand | Fluke® |
Manufacturer | Fluke Corporation |
Voltage Rating | 250/500/1,000/2,500/5,000/10,000 V |
For Capturing And Trending anomalies for troubleshooting, commissioning and preventative maintenance of insulation resistance |
Test voltages to up 10 KV and save time by trending on the spot only with fluke Connect; Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety, selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V; Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall, long battery life gives the user over 750 tests between chargesAutomatic calculation of dielectric Absorption (DAR) and polarization Index (PI) with no additional setup, guard system eliminates the effect of surface leakage current on high-resistance measurements, large digital/analog LCD for easy viewing, capacitance and leakage current measurement, ramp function for breakdown testing; Resistance measurements up to 2 TOHM, timer settings up to 99 MINT for timed tests |
Test voltages to up 10 kV and save time by trending on the spot only with fluke connect |
Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 VAC/ VDC for increased user safety, selectable test voltages in 50 V steps from 250 - 1000 V, and 100 V steps above 1000 V |
Long battery life gives the user over 750 tests between charges |
Automatic calculation of dielectric absorption (DAR) and polarization index (PI) with no additional setup |
Ramp function for breakdown testing |
Timer settings up to 99 minutes for timed tests |
Guard system eliminates the effect of surface leakage current on high-resistance measurements |
Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall |
75 x 105 mm LCD, Digital LCD/analog display |
2 deg pollution, -20 to 50 deg C temperature rating, IP rating IP40 |
5 - 20% accuracy |
PC port interface |
Hardplastic enclosure |
Voltage rating - 250, 500, 1000, 2500, 5000, 10000 V |