Appleton® EYSF75 Unilet® EYS Explosionproof Conduit Sealing Fitting, 3/4 in, For Use With IMC/Threaded Rigid Metal Conduit
Explosion Proof Conduit Sealing Fittings
17279
MFG #: EYSF75
Appleton™
36.71000
/ ea
- http://www.appletonelec.com(Seller Home Page URL)
- https://www.appleton.emerson.com/(Seller Home Page URL)
- Seller Home Page URL - appleton(Seller Home Page URL)
- Spec Sheet URL - 11043_SPE_AEC_MC007_EYS_25percent_Fill_Vertical-Conduit_Sealing_Fitting.pdf(Spec Sheet URL)
- Spec Sheet URL - SPE_AEC_MC007_EYS_25percent_Fill_Vertical-Conduit_Sealing_Fitting.pdf(Spec Sheet URL)
- Warranty URL - 11043_AFRVNTEYP0B9JHS4.pdf(Warranty URL)
- Warranty URL - appleton-grp-terms-and-conditions.pdf(Warranty URL)
- Applications
- Features
For Use With Threaded Rigid Metal Conduit and IMC |
For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations within 18 IN of enclosures containing apparatus that may cause arcs, sparks or high temperatures; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; F |
Smooth, rounded integral bushing in each hub to protect conductor insulation |
Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity |
Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub |
Large opening for damming and filling |
Restrict any explosion to the sealed off enclosure |
Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures |
Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps |
Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location |
Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure |
Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations |
Tapered FNPT connection |
25% fill vertical conduit sealing fittings |
Chromate/epoxy powder coated/zinc electroplated finish |
25% fill vertical conduit sealing fittings |
Triple-coat (Zinc electroplate, chromate and epoxy powder coat) finish |