AppletonĀ® EYS31 UniletĀ® EYS Explosionproof Conduit Sealing Fitting, 1 in, For Use With IMC/Threaded Rigid Metal Conduit
Custom_Product_Images_Illustration
AppletonĀ® EYS31 UniletĀ® EYS Explosionproof Conduit Sealing Fitting, 1 in, For Use With IMC/Threaded Rigid Metal Conduit
SKU125035
MFGR #EYS31
$/ea
These Appleton sealing fittings minimize the passage of gases and vapors and prevent the passage of flames from oneportion of a conduit system to another. They prevent pressure piling the within conduit system and contain any explosion that occurs. these models in the EYS series provide a close turning radius and can be used for sealing vertical or horizontal conduit runs.
These Appleton sealing fittings minimize the passage of gases and vapors and prevent the passage of flames from oneportion of a conduit system to another. They prevent pressure piling the within conduit system and contain any explosion that occurs. these models in the EYS series provide a close turning radius and can be used for sealing vertical or horizontal conduit runs.
Application For Use With Threaded Rigid Metal Conduit And IMC ARRA Compliant N Buy American Compliant N Catalog Number EYS31 Color Gray Connection Tapered FNPT Country of Origin MX Currency USD EU RoHS Indicator C Gross Weight Per Pack 1.5000 lb Gross Weight per Pack Metric 0.73 Gross Weight UOM Metric kg Height 0.72 in Height [Metric] 18.2880 mm Length 7.50 in Length [Metric] 19.0500 cm Standard UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181 Standards UL 886 (1203), File No. E10444, CSA C22.2 No. 30, File No. 065181, Class I, Groups A, B, C, D, Class II, Groups E, F, G and Class III Sub Brand UNILETS Type EYS Series 25 PCT Fill Vertical And Horizontal Sealing Fitting UNSPSC 39121311 UPC 11 78138162102 UPC 12 781381621021 Width 4.60 in Width [Metric] 11.6840 cm Stock Status NONSTOCK Brand Appleton⢠Manufacturer Appleton Finish Zinc Electroplate/Chromate/Epoxy Powder Coat Material Grayloy-Iron Size 1 in For Use With Threaded Rigid Metal Conduit and IMC For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations within 18 IN of enclosures containing apparatus that may cause arcs, sparks or high temperatures; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; F Smooth, rounded integral bushing in each hub protects conductor insulation Accurately tapped, tapered threads for tight, rigid joints and ground continuity Dust-ignition proof, raintight Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub Close radius type for sealing vertical or horizontal conduit runs Restrict any explosion to the sealed off enclosure Required in class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures Required in class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps Required in class I, Division 1 and 2 locations at the boundary where conduit leaves classified location Required in class I, Division 1 and 2 locations where two or more enclosures are connected by 36ā or less conduit, seal must be located within 18 in of either enclosure Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in class I, Division 2locations 1.38 in turning radius Tapered FNPT connection 25% fill vertical and horizontal sealing fittings for close turning radius Triple-Coat (Zinc Electroplate, Chromate And epoxy Powder Coat) finish
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Application | For Use With Threaded Rigid Metal Conduit And IMC |
| ARRA Compliant | N |
| Buy American Compliant | N |
| Catalog Number | EYS31 |
| Color | Gray |
| Connection | Tapered FNPT |
| Country of Origin | MX |
| Currency | USD |
| EU RoHS Indicator | C |
| Gross Weight Per Pack | 1.5000 lb |
| Gross Weight per Pack Metric | 0.73 |
| Gross Weight UOM Metric | kg |
| Height | 0.72 in |
| Height [Metric] | 18.2880 mm |
| Length | 7.50 in |
| Length [Metric] | 19.0500 cm |
| Standard | UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181 |
| Standards | UL 886 (1203), File No. E10444, CSA C22.2 No. 30, File No. 065181, Class I, Groups A, B, C, D, Class II, Groups E, F, G and Class III |
| Sub Brand | UNILETS |
| Type | EYS Series 25 PCT Fill Vertical And Horizontal Sealing Fitting |
| UNSPSC | 39121311 |
| UPC 11 | 78138162102 |
| UPC 12 | 781381621021 |
| Width | 4.60 in |
| Width [Metric] | 11.6840 cm |
| Stock Status | NONSTOCK |
| Brand | Appleton⢠|
| Manufacturer | Appleton |
| Finish | Zinc Electroplate/Chromate/Epoxy Powder Coat |
| Material | Grayloy-Iron |
| Size | 1 in |
| For Use With Threaded Rigid Metal Conduit and IMC |
| For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations within 18 IN of enclosures containing apparatus that may cause arcs, sparks or high temperatures; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; F |
| Smooth, rounded integral bushing in each hub protects conductor insulation |
| Accurately tapped, tapered threads for tight, rigid joints and ground continuity |
| Dust-ignition proof, raintight |
| Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub |
| Close radius type for sealing vertical or horizontal conduit runs |
| Restrict any explosion to the sealed off enclosure |
| Required in class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures |
| Required in class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps |
| Required in class I, Division 1 and 2 locations at the boundary where conduit leaves classified location |
| Required in class I, Division 1 and 2 locations where two or more enclosures are connected by 36ā or less conduit, seal must be located within 18 in of either enclosure |
| Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in class I, Division 2locations |
| 1.38 in turning radius |
| Tapered FNPT connection |
| 25% fill vertical and horizontal sealing fittings for close turning radius |
| Triple-Coat (Zinc Electroplate, Chromate And epoxy Powder Coat) finish |