or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Appleton® EYF150-AL Unilet® EY Series Explosionproof Conduit Sealing Fitting, 1-1/2 in, Almag 35 Aluminum, Epoxy Powder Coated
Custom_Product_Images_Illustration
Appleton® EYF150-AL Unilet® EY Series Explosionproof Conduit Sealing Fitting, 1-1/2 in, Almag 35 Aluminum, Epoxy Powder Coated
SKU423104
MFGR #EYF150-AL
Your Cost: $94.39/ea
These sealing fittings minimizes the passage of gases and vapors and prevents the passage of flames from oneportion of a conduit system to another. they prevent pressure piling the within conduit system and contain any explosion that occurs. The EY series is a close radius type for sealing vertical or horizontal conduit runs.
These sealing fittings minimizes the passage of gases and vapors and prevents the passage of flames from oneportion of a conduit system to another. they prevent pressure piling the within conduit system and contain any explosion that occurs. The EY series is a close radius type for sealing vertical or horizontal conduit runs.
Application For Use With Threaded Rigid Metal Conduit and IMC ARRA Compliant N Buy American Compliant N Catalog Number EYF150-AL Connection Female Threaded Country of Origin MX Currency USD Dimensions 5.5 in L x 2.38 in W EU RoHS Indicator C Gross Weight Per Pack 2.3800 lb Gross Weight per Pack Metric 1.08 Gross Weight UOM Metric kg Height 3.10 in Height [Metric] 7.8740 cm Length 6.50 in Length [Metric] 16.5100 cm Series EY Series Standard UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181 Standards UL 886UL 1203 File No. E10444CSA C22.2 No. 30CSA 065181RoHS Compliant Sub Brand UNILETS Type Dust-Ignitionproof Explosionproof Raintight UNSPSC 39121311 UPC 11 78138160002 UPC 12 781381600026 Width 4.70 in Width [Metric] 11.9380 cm Stock Status NONSTOCK Brand Appleton™ Manufacturer Appleton Finish Epoxy Powder Coated Material Almag 35 Aluminum Size 1-1/2 in Suitable For Use With IMC/Threaded Rigid Metallic Conduit For Use With Threaded Rigid Metal Conduit and IMC For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub; Close radius type for sealing vertical or horizontal con Smooth, rounded integral bushing in each hub to protect conductor insulation Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub Restrict any explosion to the sealed off enclosure Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations 25% fill vertical and horizontal conduit sealing fittings for close turning radius Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in class I, Division 2locations 2.06 in turning radius Female threaded connection 25% fill vertical and horizontal conduit sealing fittings for close turning radius
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Application | For Use With Threaded Rigid Metal Conduit and IMC |
ARRA Compliant | N |
Buy American Compliant | N |
Catalog Number | EYF150-AL |
Connection | Female Threaded |
Country of Origin | MX |
Currency | USD |
Dimensions | 5.5 in L x 2.38 in W |
EU RoHS Indicator | C |
Gross Weight Per Pack | 2.3800 lb |
Gross Weight per Pack Metric | 1.08 |
Gross Weight UOM Metric | kg |
Height | 3.10 in |
Height [Metric] | 7.8740 cm |
Length | 6.50 in |
Length [Metric] | 16.5100 cm |
Series | EY Series |
Standard | UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181 |
Standards | UL 886UL 1203 File No. E10444CSA C22.2 No. 30CSA 065181RoHS Compliant |
Sub Brand | UNILETS |
Type | Dust-Ignitionproof Explosionproof Raintight |
UNSPSC | 39121311 |
UPC 11 | 78138160002 |
UPC 12 | 781381600026 |
Width | 4.70 in |
Width [Metric] | 11.9380 cm |
Stock Status | NONSTOCK |
Brand | Appleton™ |
Manufacturer | Appleton |
Finish | Epoxy Powder Coated |
Material | Almag 35 Aluminum |
Size | 1-1/2 in |
Suitable For Use With | IMC/Threaded Rigid Metallic Conduit |
For Use With Threaded Rigid Metal Conduit and IMC |
For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub; Close radius type for sealing vertical or horizontal con |
Smooth, rounded integral bushing in each hub to protect conductor insulation |
Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity |
Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub |
Restrict any explosion to the sealed off enclosure |
Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures |
Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps |
Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location |
Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure |
Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations |
25% fill vertical and horizontal conduit sealing fittings for close turning radius |
Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in class I, Division 2locations |
2.06 in turning radius |
Female threaded connection |
25% fill vertical and horizontal conduit sealing fittings for close turning radius |