Amprobe® ACD-10PLUS ACD-10 PLUS Clamp Multimeter, 600 VAC/VDC, 600 A, 40 MOhm, 40 to 400 Hz, 26 mm Jaw, LCD Display
Clamp Meters
494746
MFG #: ACD-10 PLUS
Fluke®
133.99000
/ ea
Amprobe?s ACD-10 PLUS meter offers thinner jaws over standard clamp meters. Allowing access to tight measurement areas and still accommodating conductors up to 25 mm. It also measures Capacitance and Frequency. Frequency is measured by either jaws or test leads. Very versatile clamp multimeter.
- Catalog URL - IDW_DOCUMENT_63d9f38d3720f0a3a73b6586f206d257fd4bff1f6eebfb529b2ad6624131744d.pdf(Catalog URL)
- http://www.fluke.com/(Seller Home Page URL)
- Install Instructions URL - ID-INS-ACD-10_PLUS.pdf(Install Instructions URL)
- Line Drawing URL - ID-LIN-ACD-10_PLUS.png(Line Drawing URL)
- Spec Sheet URL - ACD-10%20PLUS%20Clamp-On%20Multimeter.pdf(Spec Sheet URL)
- Tech Drawing URL - ACD-10-PLUS.htm?PID=73064(Tech Drawing URL)
- Video - https://www.youtube.com/embed/aRJMNqffdlc(Video)
- Features
Thin jaws, only 10 mm THK make it easier to maneuver between tightly packed conductors |
Measures frequency, resistance and capacitance |
Features continuity beeper to quickly find opens and shorts |
Accommodates conductors up to 1 in Dia |
Auto ranging saves time by instantly selecting correct range |
Auto power off to conserve battery life |
Rubber over molded case absorbs shock |
+/-0.8% + 8 digits at 400 Ohm, +/-0.6% + 4 digits at 4 to 400 kOhm, +/-1% + 4 digits at 4 MOhm, +/-2% + 4 digits at 40 MOhm resistance accuracy |
+/-0.3% + 4 digits at 400 mVDC, +/-0.5% + 3 digits at 4 to 400 VDC, +/-1% + 4 digits at 600 VDC, +/-1.5% + 5 digits at 4 to 400 VAC, +/-2% + 5 digits at 600 VAC for 50 to 500 Hz voltage accuracy |
AC voltage range - 4 V, 40 V, 400 V with accuracy of +/-( 1.5% + 5 Digit), 600 V with accuracy of +/-( 2% + 5 Digit), CMRR - >60dB at DC to 60 Hz, Rs equal 1 kOhm, maximum crest factor - < 1.75 - 1 at full scale and < 3.5 - 1 at half scale limited to fundamental and harmonics, that fall within the meter specified AC bandwidth for non-sinusoidal waveforms, input impedance - 10 MOhm, 30 pF nominal, transient protection - 6.5 kV (1.2/50us surge), ACD-10 plus - average sensing |
DC voltage range - 400 mV with accuracy of +/-( 0.3% + 4 Digit), 4 V, 40 V, 400 V with accuracy of +/-( 0.5% + 3 Digit), 600 V with accuracy of +/-( 1% + 4 Digit), NMRR - >50 dB at 50/60 Hz, CMRR - >120 dB at DC, 50/60 Hz, Rs equal 1 kOhm, input impedance - 10 MOhm, 30 pF nominal (1000 MOhm for 400 mV range), transient protection - 6.5 kV (1.2/50 u second surge) |
Capacitance - 500 nF, 5 F, 50 CF, 500 u F, 3000 u F with accuracy of ( 3.5% + 6 digits) |
Capacitance - 500 nF, 5 F, 50 CF, 500 u F, 3000 u F with accuracy of ( 3.5% + 6 digits) |