1-1/4 FEMALE SEAL-OFF
SKU84894
MFGR #EYS4
Your Cost: $40.72/ea
These Appleton sealing fittings minimize the passage of gases and vapors and prevent the passage of flames from oneportion of a conduit system to another. They prevent pressure piling the within conduit system and contain any explosion that occurs. these models in the EYS series provide a close turning radius and can be used for sealing vertical or horizontal conduit runs.
These Appleton sealing fittings minimize the passage of gases and vapors and prevent the passage of flames from oneportion of a conduit system to another. They prevent pressure piling the within conduit system and contain any explosion that occurs. these models in the EYS series provide a close turning radius and can be used for sealing vertical or horizontal conduit runs.
Application For Use With Threaded Rigid Metal Conduit and IMC ARRA Compliant N Buy American Compliant N Catalog Number EYS4 Color Gray Connection Tapered FNPT Country of Origin MX Currency USD Dimensions 5.06 in L x 2.19 in W EU RoHS Indicator C Gross Weight Per Pack 5.3600 lb Gross Weight per Pack Metric 2.43 Gross Weight UOM Metric kg Height 3.50 in Height [Metric] 8.8900 cm Length 6.50 in Length [Metric] 16.5100 cm Series EYS Standard UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181 Standards UL 886UL 1203 File No. E10444CSA C22.2 No. 30CSA 065181RoHS Compliant Sub Brand UNILETS Type Dust-Ignitionproof Explosionproof Raintight UNSPSC 39121311 UPC 11 78138162103 UPC 12 781381621038 Width 5.00 in Width [Metric] 12.7000 cm Stock Status NONSTOCK Brand Appleton™ Manufacturer Appleton Finish Zinc Electroplate/Chromate/Epoxy Powder Coat Material Grayloy-Iron Size 1-1/4 in Suitable For Use With IMC/Threaded Rigid Metallic Conduit For Use With Threaded Rigid Metal Conduit and IMC For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations within 18 IN of enclosures containing apparatus that may cause arcs, sparks or high temperatures; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; F Smooth, rounded integral bushing in each hub to protect conductor insulation Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub Large opening for damming and filling Restrict any explosion to the sealed off enclosure Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations Tapered FNPT connection 25% fill vertical and horizontal conduit sealing fittings for close turning radius Chromate/epoxy powder coated/zinc electroplated finish 25% fill vertical and horizontal sealing fittings for close turning radius Triple-Coat (Zinc Electroplate, Chromate And epoxy Powder Coat) finish
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Application | For Use With Threaded Rigid Metal Conduit and IMC |
| ARRA Compliant | N |
| Buy American Compliant | N |
| Catalog Number | EYS4 |
| Color | Gray |
| Connection | Tapered FNPT |
| Country of Origin | MX |
| Currency | USD |
| Dimensions | 5.06 in L x 2.19 in W |
| EU RoHS Indicator | C |
| Gross Weight Per Pack | 5.3600 lb |
| Gross Weight per Pack Metric | 2.43 |
| Gross Weight UOM Metric | kg |
| Height | 3.50 in |
| Height [Metric] | 8.8900 cm |
| Length | 6.50 in |
| Length [Metric] | 16.5100 cm |
| Series | EYS |
| Standard | UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181 |
| Standards | UL 886UL 1203 File No. E10444CSA C22.2 No. 30CSA 065181RoHS Compliant |
| Sub Brand | UNILETS |
| Type | Dust-Ignitionproof Explosionproof Raintight |
| UNSPSC | 39121311 |
| UPC 11 | 78138162103 |
| UPC 12 | 781381621038 |
| Width | 5.00 in |
| Width [Metric] | 12.7000 cm |
| Stock Status | NONSTOCK |
| Brand | Appleton™ |
| Manufacturer | Appleton |
| Finish | Zinc Electroplate/Chromate/Epoxy Powder Coat |
| Material | Grayloy-Iron |
| Size | 1-1/4 in |
| Suitable For Use With | IMC/Threaded Rigid Metallic Conduit |
| For Use With Threaded Rigid Metal Conduit and IMC |
| For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations within 18 IN of enclosures containing apparatus that may cause arcs, sparks or high temperatures; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; F |
| Smooth, rounded integral bushing in each hub to protect conductor insulation |
| Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity |
| Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub |
| Large opening for damming and filling |
| Restrict any explosion to the sealed off enclosure |
| Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures |
| Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps |
| Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location |
| Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure |
| Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations |
| Tapered FNPT connection |
| 25% fill vertical and horizontal conduit sealing fittings for close turning radius |
| Chromate/epoxy powder coated/zinc electroplated finish |
| 25% fill vertical and horizontal sealing fittings for close turning radius |
| Triple-Coat (Zinc Electroplate, Chromate And epoxy Powder Coat) finish |