1-1/4 FEMALE SEAL-OFF
Explosion Proof Conduit Sealing Fittings
84894
MFG #: EYS4
Appleton™
62.80000
/ ea
These Appleton sealing fittings minimize the passage of gases and vapors and prevent the passage of flames from oneportion of a conduit system to another. They prevent pressure piling the within conduit system and contain any explosion that occurs. these models in the EYS series provide a close turning radius and can be used for sealing vertical or horizontal conduit runs.
- Applications
- Features
For Use With Threaded Rigid Metal Conduit and IMC |
For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations within 18 IN of enclosures containing apparatus that may cause arcs, sparks or high temperatures; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing i |
Smooth, rounded integral bushing in each hub to protect conductor insulation |
Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity |
Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub |
Large opening for damming and filling |
Restrict any explosion to the sealed off enclosure |
Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures |
Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps |
Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location |
Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure |
Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations |
Tapered FNPT connection |
25% fill vertical and horizontal conduit sealing fittings for close turning radius |
Chromate/epoxy powder coated/zinc electroplated finish |
25% fill vertical and horizontal sealing fittings for close turning radius |
Triple-Coat (Zinc Electroplate, Chromate And epoxy Powder Coat) finish |