Appleton® ENR5201 U-Line® Contender® Pin and Sleeve Receptacle Cover Assembly, 125 VAC, 20 A, 3 Poles, 2 Wires
Custom_Product_Images_Illustration
Appleton® ENR5201 U-Line® Contender® Pin and Sleeve Receptacle Cover Assembly, 125 VAC, 20 A, 3 Poles, 2 Wires
SKU85203
MFGR #ENR5201
Your Cost: $509.28/ea
U-Line® Contender® plugs and receptacles offer all the advantages of U-Line technology without the need to replace competitors back boxes that have already been installed. Simply change out the receptacle and your company can benefit from the safety, flexibility and value of U-Line. Appleton provides its own compatible back boxes, so you can continue to expand your facility using a single vendor. U-Line Contender plugs and receptacles allow the use of electrical equipment in hazardous locations. In non-hazardous locations, the U-Line ECP plug fits into standard NEMA 5-20R and 6-20R receptacles. In hazardous locations, the same U-Line plug is the key to energizing the explosionproof U-Line receptacle. A twist of the plug makes electrical contact and locks the plug in place with an audible click. The neoprene gasket in the throat of the receptacle seals against the plug or the spring-loaded cover to seal out water, dust and corrosive compounds. Although U-Line plugs can be used with ordinary receptacles, U-Line receptacles are designed so that they cant be energized by an ordinary plug-ensuring that only safe connections can be made in a hazardous location.
U-Line® Contender® plugs and receptacles offer all the advantages of U-Line technology without the need to replace competitors back boxes that have already been installed. Simply change out the receptacle and your company can benefit from the safety, flexibility and value of U-Line. Appleton provides its own compatible back boxes, so you can continue to expand your facility using a single vendor. U-Line Contender plugs and receptacles allow the use of electrical equipment in hazardous locations. In non-hazardous locations, the U-Line ECP plug fits into standard NEMA 5-20R and 6-20R receptacles. In hazardous locations, the same U-Line plug is the key to energizing the explosionproof U-Line receptacle. A twist of the plug makes electrical contact and locks the plug in place with an audible click. The neoprene gasket in the throat of the receptacle seals against the plug or the spring-loaded cover to seal out water, dust and corrosive compounds. Although U-Line plugs can be used with ordinary receptacles, U-Line receptacles are designed so that they cant be energized by an ordinary plug-ensuring that only safe connections can be made in a hazardous location.
Application For ECP Mating Plugs ARRA Compliant N Buy American Compliant N Catalog Number ENR5201 Country of Origin MX Currency USD Dimensions 4.2 in H x 5 in W x 7 in D EU RoHS Indicator N Gross Weight Per Pack 1.8900 lb Gross Weight per Pack Metric 0.86 Gross Weight UOM Metric kg Height 4.20 in Height [Metric] 10.6680 cm Length 7.00 in Length [Metric] 17.7800 cm Material Copper Free Aluminum Mounting Box NEMA Rating NEMA 3RX Number Of Poles 3 Standard Class I, Groups C, D; Class I, Division 2, Group B; Class I, Zone 1, Group IIB; Class I, Zone 2, Group IIB + H2; Class II, Groups F, G; Class III; UL Listed: E10784; UL 1203, UL 1010, UL 894 Standards Class I, Groups C, D, Class I, Div 2, Group B, Class I, Zone 1, Group IIB, Class I, Zone 2, Group IIB + H2, Class II, Groups F, G, Class IIIUL File No. E10784UL 1203/1010/894 Sub Brand Contender Type Dust-Ignitionproof Replacement UNSPSC 39121406 UPC 11 78138181502 UPC 12 781381815024 Width 5.00 in Width [Metric] 12.7000 cm Stock Status NONSTOCK Brand Appleton™ Manufacturer Appleton Amperage Rating 20 A Number of Wires 2 Voltage Rating 125 VAC For ECP Mating Plugs Explosionproof, dust-ignitionproof; Insulators provide superior dielectric and mechanical strength and lowest arc tracking; Fiberglass reinforced thermoset polyester insulating blocks; Dead front design: receptacle is not energized until plug is fully inserted and switch is engaged; ECP plug fits U-Line explosionproof receptacles; U-Line Contender receptacles only available for use in combination with 1 and 2-gang EDS boxes incorporating such devices as pilot lights, switches and push buttons; For lighting systems, conveyors, heaters, motor-generator sets, air conditioners, compressors, pumps Explosion proof, dust-ignition proof Covers are UL Listed when used with contender series back boxes Insulators provide superior dielectric and mechanical strength and lowest arc tracking Dead front design: receptacle is not energized until plug is fully inserted and switch is engaged ECP plug fits U-Line explosion proof receptacles U-Line Contender receptacles only available for use in combination with 1- and 2-gang EDS boxes incorporating such devices as pilot lights, switches and push buttons Fiberglass reinforced thermoset polyester insulating blocks Surface mount For lighting systems, conveyors, heaters, motor-generator sets, air conditioners, compressors, pumps Epoxy powder coated copper free (4/10 of 1 pct) aluminum cover Malleable iron mounting box
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Application | For ECP Mating Plugs |
ARRA Compliant | N |
Buy American Compliant | N |
Catalog Number | ENR5201 |
Country of Origin | MX |
Currency | USD |
Dimensions | 4.2 in H x 5 in W x 7 in D |
EU RoHS Indicator | N |
Gross Weight Per Pack | 1.8900 lb |
Gross Weight per Pack Metric | 0.86 |
Gross Weight UOM Metric | kg |
Height | 4.20 in |
Height [Metric] | 10.6680 cm |
Length | 7.00 in |
Length [Metric] | 17.7800 cm |
Material | Copper Free Aluminum |
Mounting | Box |
NEMA Rating | NEMA 3RX |
Number Of Poles | 3 |
Standard | Class I, Groups C, D; Class I, Division 2, Group B; Class I, Zone 1, Group IIB; Class I, Zone 2, Group IIB + H2; Class II, Groups F, G; Class III; UL Listed: E10784; UL 1203, UL 1010, UL 894 |
Standards | Class I, Groups C, D, Class I, Div 2, Group B, Class I, Zone 1, Group IIB, Class I, Zone 2, Group IIB + H2, Class II, Groups F, G, Class IIIUL File No. E10784UL 1203/1010/894 |
Sub Brand | Contender |
Type | Dust-Ignitionproof Replacement |
UNSPSC | 39121406 |
UPC 11 | 78138181502 |
UPC 12 | 781381815024 |
Width | 5.00 in |
Width [Metric] | 12.7000 cm |
Stock Status | NONSTOCK |
Brand | Appleton™ |
Manufacturer | Appleton |
Amperage Rating | 20 A |
Number of Wires | 2 |
Voltage Rating | 125 VAC |
For ECP Mating Plugs |
Explosionproof, dust-ignitionproof; Insulators provide superior dielectric and mechanical strength and lowest arc tracking; Fiberglass reinforced thermoset polyester insulating blocks; Dead front design: receptacle is not energized until plug is fully inserted and switch is engaged; ECP plug fits U-Line explosionproof receptacles; U-Line Contender receptacles only available for use in combination with 1 and 2-gang EDS boxes incorporating such devices as pilot lights, switches and push buttons; For lighting systems, conveyors, heaters, motor-generator sets, air conditioners, compressors, pumps |
Explosion proof, dust-ignition proof |
Covers are UL Listed when used with contender series back boxes |
Insulators provide superior dielectric and mechanical strength and lowest arc tracking |
Dead front design: receptacle is not energized until plug is fully inserted and switch is engaged |
ECP plug fits U-Line explosion proof receptacles |
U-Line Contender receptacles only available for use in combination with 1- and 2-gang EDS boxes incorporating such devices as pilot lights, switches and push buttons |
Fiberglass reinforced thermoset polyester insulating blocks |
Surface mount |
For lighting systems, conveyors, heaters, motor-generator sets, air conditioners, compressors, pumps |
Epoxy powder coated copper free (4/10 of 1 pct) aluminum cover |
Malleable iron mounting box |