Appleton® EFSCB175-2023M U-Line® Pin and Sleeve Receptacle Assembly, 125 VAC, 20 A, 3 Poles, 2 Wires
Custom_Product_Images_Illustration
Appleton® EFSCB175-2023M U-Line® Pin and Sleeve Receptacle Assembly, 125 VAC, 20 A, 3 Poles, 2 Wires
SKU289698
MFGR #EFSCB1752023M
Your Cost: $1,023.36/ea
U-Line® plugs and receptacles allow the use of electrical equipment in hazardous locations. In non-hazardous locations, the U-Line ECP plug fits into standard NEMA 5-20R and 6-20R receptacles. In hazardous locations, the same U-Line plug is the key to energizing the explosionproof U-Line receptacle. Although U-Line plugs can be used with ordinary receptacles, U-Line receptacles are designed so that they cant be energized by an ordinary plug - ensuring that only safe connections can be made in a hazardous location. Its an convenient, time- and money-saving solution for handheld tools, lighting and other equipment that might be used in both ordinary and hazardous locations. When using a U-Line plug in an explosionproof U-Line receptacle, a twist of the plug makes electrical contact and locks the plug in place with an audible click. The neoprene gasket in the throat of the receptacle seals against the plug or the spring-loaded cover to seal out water, dust and corrosive compounds.
U-Line® plugs and receptacles allow the use of electrical equipment in hazardous locations. In non-hazardous locations, the U-Line ECP plug fits into standard NEMA 5-20R and 6-20R receptacles. In hazardous locations, the same U-Line plug is the key to energizing the explosionproof U-Line receptacle. Although U-Line plugs can be used with ordinary receptacles, U-Line receptacles are designed so that they cant be energized by an ordinary plug - ensuring that only safe connections can be made in a hazardous location. Its an convenient, time- and money-saving solution for handheld tools, lighting and other equipment that might be used in both ordinary and hazardous locations. When using a U-Line plug in an explosionproof U-Line receptacle, a twist of the plug makes electrical contact and locks the plug in place with an audible click. The neoprene gasket in the throat of the receptacle seals against the plug or the spring-loaded cover to seal out water, dust and corrosive compounds.
Application For CPH And ECP Mating Plugs ARRA Compliant N Buy American Compliant N Catalog Number EFSCB1752023M Country of Origin MX Currency USD Dimensions 6.5 in H x 2.75 in W x 5.64 in D EU RoHS Indicator C Gross Weight Per Pack 6.7600 lb Gross Weight per Pack Metric 3.07 Gross Weight UOM Metric kg Height 3.80 in Height [Metric] 9.6520 cm Horsepower 1 hp Length 7.00 in Length [Metric] 17.7800 cm Material Malleable Iron Mounting Surface Mount With 3/4 IN Feed-Thru Hub NEMA Rating NEMA 3/3R Number Of Poles 3 Standard Class I, Division 1 And 2, Groups B, C, D; Class II, Division 1 And 2, Groups F, G; Class III; UL Listed: E10784, E81751; UL Standard: 1203, 1010, 894; CSA Standard: C22.2 No. 25, C22.2 No. 30, C22.2 No. 42, C22 No.159; CSA Certified: 038644 Standards Class I, Div 1 and 2, Groups B, C, D, Class II, Div 1 and 2, Groups F, G, Class IIIUL File No. E10784/E81751UL 1203/1010/894CSA C22.2 No. 25/30/42/159CSA File No. 038644RoHS Compliant Sub Brand U-Line Type 1-Gang Dust-Ignitionproof Feed Through UNSPSC 39121406 UPC 11 78138139733 UPC 12 781381397339 Width 6.70 in Width [Metric] 17.0180 cm Stock Status NONSTOCK Brand Appleton™ Manufacturer Appleton Amperage Rating 20 A Number of Wires 2 Voltage Rating 125 VAC For CPH And ECP Mating Plugs Explosionproof, dust-ignitionproof; Factory sealed, external seals not required in most areas, arcing is safely confined to receptacle interior; For lighting systems, conveyors, heaters, motor-generator sets, air conditioners, compressors, pumps; These models have separate factory sealed chamber - suitable for Class I, Group B as well as Class I, Groups C and D, Class II, Groups F, G and Class III (No external seals required); Spring cover; Glass-filled reinforced polyester insulating blocks Factory sealed, external seals not required in most areas, arcing is safely confined to receptacle interior Glass filled reinforced polyester insulating blocks Energized receptacle contacts deeply recessed to reduce danger of accidental touching These models have separate factory sealed chamber Unique blade type, brass contacts exert constant pressure along entire contact surface and provide superior electrical contact Insulators provide superior dielectric and mechanical strength and lowest arc tracking ECP plug fits any standard non explosionproof receptacle (NEMA 5-20R, or 6-20R) as well as U-Line™ explosionproof receptacles Intermateable with competitor's plugs of like configurations Surface mount 3/4 in feed-thru hub 1-gang For lighting systems, conveyors, heaters, motor-generator sets, air conditioners, compressors, pumps Malleable iron receptacle Epoxy powder coat With mounting box
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Application | For CPH And ECP Mating Plugs |
ARRA Compliant | N |
Buy American Compliant | N |
Catalog Number | EFSCB1752023M |
Country of Origin | MX |
Currency | USD |
Dimensions | 6.5 in H x 2.75 in W x 5.64 in D |
EU RoHS Indicator | C |
Gross Weight Per Pack | 6.7600 lb |
Gross Weight per Pack Metric | 3.07 |
Gross Weight UOM Metric | kg |
Height | 3.80 in |
Height [Metric] | 9.6520 cm |
Horsepower | 1 hp |
Length | 7.00 in |
Length [Metric] | 17.7800 cm |
Material | Malleable Iron |
Mounting | Surface Mount With 3/4 IN Feed-Thru Hub |
NEMA Rating | NEMA 3/3R |
Number Of Poles | 3 |
Standard | Class I, Division 1 And 2, Groups B, C, D; Class II, Division 1 And 2, Groups F, G; Class III; UL Listed: E10784, E81751; UL Standard: 1203, 1010, 894; CSA Standard: C22.2 No. 25, C22.2 No. 30, C22.2 No. 42, C22 No.159; CSA Certified: 038644 |
Standards | Class I, Div 1 and 2, Groups B, C, D, Class II, Div 1 and 2, Groups F, G, Class IIIUL File No. E10784/E81751UL 1203/1010/894CSA C22.2 No. 25/30/42/159CSA File No. 038644RoHS Compliant |
Sub Brand | U-Line |
Type | 1-Gang Dust-Ignitionproof Feed Through |
UNSPSC | 39121406 |
UPC 11 | 78138139733 |
UPC 12 | 781381397339 |
Width | 6.70 in |
Width [Metric] | 17.0180 cm |
Stock Status | NONSTOCK |
Brand | Appleton™ |
Manufacturer | Appleton |
Amperage Rating | 20 A |
Number of Wires | 2 |
Voltage Rating | 125 VAC |
For CPH And ECP Mating Plugs |
Explosionproof, dust-ignitionproof; Factory sealed, external seals not required in most areas, arcing is safely confined to receptacle interior; For lighting systems, conveyors, heaters, motor-generator sets, air conditioners, compressors, pumps; These models have separate factory sealed chamber - suitable for Class I, Group B as well as Class I, Groups C and D, Class II, Groups F, G and Class III (No external seals required); Spring cover; Glass-filled reinforced polyester insulating blocks |
Factory sealed, external seals not required in most areas, arcing is safely confined to receptacle interior |
Glass filled reinforced polyester insulating blocks |
Energized receptacle contacts deeply recessed to reduce danger of accidental touching |
These models have separate factory sealed chamber |
Unique blade type, brass contacts exert constant pressure along entire contact surface and provide superior electrical contact |
Insulators provide superior dielectric and mechanical strength and lowest arc tracking |
ECP plug fits any standard non explosionproof receptacle (NEMA 5-20R, or 6-20R) as well as U-Line™ explosionproof receptacles |
Intermateable with competitor's plugs of like configurations |
Surface mount |
3/4 in feed-thru hub |
1-gang |
For lighting systems, conveyors, heaters, motor-generator sets, air conditioners, compressors, pumps |
Malleable iron receptacle |
Epoxy powder coat |
With mounting box |