Appleton® ECCL2023 U-Line® Cable Connector, 125 VAC, 20 A, 3 Poles, 2 Wires
Custom_Product_Images_Illustration
Appleton™
Appleton® ECCL2023 U-Line® Cable Connector, 125 VAC, 20 A, 3 Poles, 2 Wires
SKU258216
MFGR #ECCL2023
These CSA Certified cable connectors provide an easy way to extend the reach of your power supply to areas where a standard or U-Line® receptacle may not be available. A gasket in the throat of the cable connector seals around the U-Line plug powering your equipment, protecting against moisture and combustible dusts. A twist with an audible click locks the plug in place and energizes the connector. When not in use, a spring cover seals the connector against the environment.
These CSA Certified cable connectors provide an easy way to extend the reach of your power supply to areas where a standard or U-Line® receptacle may not be available. A gasket in the throat of the cable connector seals around the U-Line plug powering your equipment, protecting against moisture and combustible dusts. A twist with an audible click locks the plug in place and energizes the connector. When not in use, a spring cover seals the connector against the environment.
Application For Connecting Portable Devices Having ECP U-Line Plugs To Existing Receptacles In Non-Hazardous Areas ARRA Compliant N Buy American Compliant N Catalog Number ECCL2023 Country of Origin MX Currency USD Dimensions 2.5 in Dia x 7.28 in L EU RoHS Indicator C Gross Weight Per Pack 0.0002 lb Gross Weight per Pack Metric 0.82 Gross Weight UOM Metric kg Height 4.00 in Height [Metric] 10.1600 cm Horsepower 1 hp Length 8.00 in Length [Metric] 20.3200 cm Material Copper Free Aluminum NEMA Rating NEMA 3/3R/7BCD/9FG Number Of Poles 3 Standard Class I, Division 1 And 2, Groups B, C, D; Class II, Division, 1 and 2 Groups F, G; Class III; CSA Standard: C22.2 No.25, C22.2 No. 30, C22.2 No. 159; CSA Certified: 038644 Standards Class I, Division 1 and 2, Groups B, C, D, Class II, Division, 1 and 2 Groups F, G, Class III, CSA C22.2 No.25, C22.2 No. 30, C22.2 No. 159, CSA File No. 038644RoHs Compliant Sub Brand U-Line Type Cable Connector With Spring Cover UNSPSC 39121406 UPC 11 78138144076 UPC 12 781381440769 Width 5.00 in Width [Metric] 12.7000 cm Stock Status NONSTOCK Brand Appleton™ Manufacturer Appleton Amperage Rating 20 A Number of Wires 2 Voltage Rating 125 VAC For Connecting Portable Devices Having ECP U-Line Plugs To Existing Receptacles In Non-Hazardous Areas Completed adapter set consists of ECCL (or ECC), short flexible cord and plug to fit existing receptacle; Gasketed spring cover snaps shut to protect against moisture and combustible dust; Gasket in receptacle throat seals around plug for protection against environment; Interior switch cylinder; o-ring at each end to seals combustible dust and moisture; 2 bushings to accommodate various cable sizes; Neoprene o-ring; Dead-front safety construction Completed adapter set consists of ECCL (ECC), short flexible cord and plug to fit existing receptacle Gasketed spring cover snaps shut to protect against moisture and combustible dust Gasket in receptacle throat seals around plug for protection against environment Interior switch cylinder O-ring at each end to seals combustible dust and moisture Two bushings to accommodate various cable sizes Neoprene O-ring Dead front safety construction Dead-front safety construction For use in CEC governed locations
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Application | For Connecting Portable Devices Having ECP U-Line Plugs To Existing Receptacles In Non-Hazardous Areas |
ARRA Compliant | N |
Buy American Compliant | N |
Catalog Number | ECCL2023 |
Country of Origin | MX |
Currency | USD |
Dimensions | 2.5 in Dia x 7.28 in L |
EU RoHS Indicator | C |
Gross Weight Per Pack | 0.0002 lb |
Gross Weight per Pack Metric | 0.82 |
Gross Weight UOM Metric | kg |
Height | 4.00 in |
Height [Metric] | 10.1600 cm |
Horsepower | 1 hp |
Length | 8.00 in |
Length [Metric] | 20.3200 cm |
Material | Copper Free Aluminum |
NEMA Rating | NEMA 3/3R/7BCD/9FG |
Number Of Poles | 3 |
Standard | Class I, Division 1 And 2, Groups B, C, D; Class II, Division, 1 and 2 Groups F, G; Class III; CSA Standard: C22.2 No.25, C22.2 No. 30, C22.2 No. 159; CSA Certified: 038644 |
Standards | Class I, Division 1 and 2, Groups B, C, D, Class II, Division, 1 and 2 Groups F, G, Class III, CSA C22.2 No.25, C22.2 No. 30, C22.2 No. 159, CSA File No. 038644RoHs Compliant |
Sub Brand | U-Line |
Type | Cable Connector With Spring Cover |
UNSPSC | 39121406 |
UPC 11 | 78138144076 |
UPC 12 | 781381440769 |
Width | 5.00 in |
Width [Metric] | 12.7000 cm |
Stock Status | NONSTOCK |
Brand | Appleton™ |
Manufacturer | Appleton |
Amperage Rating | 20 A |
Number of Wires | 2 |
Voltage Rating | 125 VAC |
For Connecting Portable Devices Having ECP U-Line Plugs To Existing Receptacles In Non-Hazardous Areas |
Completed adapter set consists of ECCL (or ECC), short flexible cord and plug to fit existing receptacle; Gasketed spring cover snaps shut to protect against moisture and combustible dust; Gasket in receptacle throat seals around plug for protection against environment; Interior switch cylinder; o-ring at each end to seals combustible dust and moisture; 2 bushings to accommodate various cable sizes; Neoprene o-ring; Dead-front safety construction |
Completed adapter set consists of ECCL (ECC), short flexible cord and plug to fit existing receptacle |
Gasketed spring cover snaps shut to protect against moisture and combustible dust |
Gasket in receptacle throat seals around plug for protection against environment |
Interior switch cylinder |
O-ring at each end to seals combustible dust and moisture |
Two bushings to accommodate various cable sizes |
Neoprene O-ring |
Dead front safety construction |
Dead-front safety construction |