or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Leviton®
Leviton® PCATR Atrium Photocell, 24 VDC, 1/2 in IPT Mount
Custom_Product_Images_Illustration
Leviton®
Leviton® PCATR Atrium Photocell, 24 VDC, 1/2 in IPT Mount
SKU897359
MFGR #PCATR
Your Cost: $359.83/ea
Leviton's photocell sensors precisely monitor either task or ambient light levels. As part of a Leviton lighting and energy solution, photocells work with other components in the system to automatically adjust light levels to a user defined level. Photocells are most suitable for installation in rooms with windows and open spaces receiving substantial ambient light. Photocells must be hardwired to a compatible Leviton lighting control system. The photocell measures ambient light in a specific area and sends this data to a dimmer or relay that, in turn, adjusts fixtures to a constant lighting level as measured in that specific area. Daylight harvesting is achieved as lights in a room (with windows or significant, artificial ambient light) automatically brighten or dim depending on how much light the photocell detects.
Leviton's photocell sensors precisely monitor either task or ambient light levels. As part of a Leviton lighting and energy solution, photocells work with other components in the system to automatically adjust light levels to a user defined level. Photocells are most suitable for installation in rooms with windows and open spaces receiving substantial ambient light. Photocells must be hardwired to a compatible Leviton lighting control system. The photocell measures ambient light in a specific area and sends this data to a dimmer or relay that, in turn, adjusts fixtures to a constant lighting level as measured in that specific area. Daylight harvesting is achieved as lights in a room (with windows or significant, artificial ambient light) automatically brighten or dim depending on how much light the photocell detects.
Amperage Rating 10 mA Application Commercial ARRA Compliant C Buy American Compliant C Catalog Number PCATR Color White Country of Origin US Currency USD Dimensions 1.28 in Dia x 2.25 in H Enclosure Type IP65 Environmental Conditions Operating Temperature Range (-11 to +60 DEG C);Humidity (20% to 90% Non-Condensing) EU RoHS Indicator C Gross Weight Per Pack 0.2000 lb Gross Weight per Pack Metric 0.09 Gross Weight UOM Metric kg Height 10.2500 in Height [Metric] 7.7800 cm Length 13.2500 in Length [Metric] 8.0162 cm Mounting 1/2 IN IPT Sensitivity 0 to 1000 fc Size 1.28 Dia x 2.25 H in Standards ARRA CompliantBuy American Act CompliantRoHS CompliantASHRAE 90.1Title 24 Compliant Supply Voltage 24 VDC Type Photocell UNSPSC 45111808 UPC 11 07847723559 UPC 12 078477235591 Width 3.16 in Width [Metric] 8.0162 cm Stock Status NONSTOCK Brand Leviton® Manufacturer Leviton Manufacturing Co., Inc. Voltage Rating 24 VDC Commercial PCATR Atrium Photocell with Opaque Dome Lens Filters 33 PCT of Light Level in Upper Atrium. Default Setting=0-1000fc Sensing Range:Can Be Field Adjusted to 2500fc Max Sensing Range, Made in Please Contact Customer Service PCATR atrium photocell with opaque dome lens filters 33% of light level in upper atrium Default setting 215 to 2690 FC sensing range, can be field adjusted to 2690 FC maximum sensing range Lowers electric bills by reducing usage of lighting where ambient natural light is also present Lumens maintenance opportunity compatible Indoor photocells designed with a flat Fresnel lens looks downward in a 60 deg cone of reference to measure actual light on the work surface and reduce the influence of stray light striking the photocell from nearby windows or incidental side lighting Measures light from any source in the visible spectrum within a 60 deg cone or 180 deg angle of response depending on the model PCATR-000 atrium photocell with opaque dome lens filters 33% of light level in upper atrium Default setting - 215 to 2690 FC sensing range Can be field adjusted to 2690 FC max sensing range Horizontal orientation
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Amperage Rating | 10 mA |
Application | Commercial |
ARRA Compliant | C |
Buy American Compliant | C |
Catalog Number | PCATR |
Color | White |
Country of Origin | US |
Currency | USD |
Dimensions | 1.28 in Dia x 2.25 in H |
Enclosure Type | IP65 |
Environmental Conditions | Operating Temperature Range (-11 to +60 DEG C);Humidity (20% to 90% Non-Condensing) |
EU RoHS Indicator | C |
Gross Weight Per Pack | 0.2000 lb |
Gross Weight per Pack Metric | 0.09 |
Gross Weight UOM Metric | kg |
Height | 10.2500 in |
Height [Metric] | 7.7800 cm |
Length | 13.2500 in |
Length [Metric] | 8.0162 cm |
Mounting | 1/2 IN IPT |
Sensitivity | 0 to 1000 fc |
Size | 1.28 Dia x 2.25 H in |
Standards | ARRA CompliantBuy American Act CompliantRoHS CompliantASHRAE 90.1Title 24 Compliant |
Supply Voltage | 24 VDC |
Type | Photocell |
UNSPSC | 45111808 |
UPC 11 | 07847723559 |
UPC 12 | 078477235591 |
Width | 3.16 in |
Width [Metric] | 8.0162 cm |
Stock Status | NONSTOCK |
Brand | Leviton® |
Manufacturer | Leviton Manufacturing Co., Inc. |
Voltage Rating | 24 VDC |
Commercial |
PCATR Atrium Photocell with Opaque Dome Lens Filters 33 PCT of Light Level in Upper Atrium. Default Setting=0-1000fc Sensing Range:Can Be Field Adjusted to 2500fc Max Sensing Range, Made in Please Contact Customer Service |
PCATR atrium photocell with opaque dome lens filters 33% of light level in upper atrium |
Default setting 215 to 2690 FC sensing range, can be field adjusted to 2690 FC maximum sensing range |
Lowers electric bills by reducing usage of lighting where ambient natural light is also present |
Lumens maintenance opportunity compatible |
Indoor photocells designed with a flat Fresnel lens looks downward in a 60 deg cone of reference to measure actual light on the work surface and reduce the influence of stray light striking the photocell from nearby windows or incidental side lighting |
Measures light from any source in the visible spectrum within a 60 deg cone or 180 deg angle of response depending on the model |
PCATR-000 atrium photocell with opaque dome lens filters 33% of light level in upper atrium |
Default setting - 215 to 2690 FC sensing range |
Can be field adjusted to 2690 FC max sensing range |
Horizontal orientation |