Leviton® MZD22-102 Dimming Daylighting Control System, 120/277 VAC, 20 A

Lighting Control Systems
817384 MFG #: MZD22-102
Leviton®
377.08000 / ea
  • Application: Lighting Controls
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: MZD22-102
  • Country of Origin: US
  • Currency: USD
  • Dimensions: 6.65 in H x 6.65 in W x 2.1 in D
  • Dimming Rate: 0 to 10 VDC
  • EU RoHS Indicator: C
  • Frequency Rating: 50/60
  • Gross Weight Per Pack: 4.0000 lb
  • Gross Weight per Pack Metric: 1.81
  • Height: 8.2500 in
  • Lamp Type: Fluorescent
  • Length: 8.2500 in
  • Operating Frequency: 50/60 Hz
  • Size: 6.65 L x 6.65 H x 2.1 D in
  • Specifications: 10 W Fluorescent Lamp
  • Standard: UL and cUL Listed;CEC Title-24 Listed
  • Standards: cUL/CEC Title-24, UL Listed
  • Sub Brand: Mini-Z
  • UNSPSC: 39112401
  • UPC 11: 07847733628
  • UPC 12: 078477336281
  • Wattage: 10 W
  • Stock Status: NONSTOCK
  • Brand: Leviton®
  • Manufacturer: Leviton Manufacturing Co., Inc.
  • Amperage Rating: 15 A
  • Type: Self-Configuring Daylight Harvesting System
  • Voltage Rating: 347 VAC
The dual room miniZ™ Controller allows two individual rooms to be independently controlled (single zone for each room) and offers the same performance features as the popular miniZ™ Controller with a compact, versatile, cost-effective, code-compliant approach to daylight harvesting.
QTY
  • Applications
  • Features
Lighting Controls
Two Individual Room Control (Single Zone for Each Room) Combining Separate Daylight Harvesting, Occupancy Sensors, and Switching in One Compact Box, Ladderless Commissioning Provides in stall-And- forget Convenience, Autocal Setting Automatic Photocell
Two individual room control (single zone for each room) combining separate daylight harvesting, occupancy sensors and switching in one compact box
Ladder less Commissioning™ provides install-and-forget convenience
Autocal™ (patent pending) automatic photocell calibration
Automatic closed loop setting (one zone per room) daylight control
Automatic Correction setting for light loss factor (LLF) recognizes and corrects for Lumens maintenance Issues
Simplified daylight harvesting with 3% to 100% dimming capabilities (0 to 10 V fluorescent dimming ballasts required)
Automatic daylight Harvest mode provides optimum lighting output for additional energy savings potential
Convenient two occupancy sensor and two photocell integration
Daylight switching, full range 0 to 10 V dimming and network models available
Cost effective energy code compliance
Simplified integration with emergency and building automation systems
Accepts external time clock inputs
Closed loop or open loop daylight control
Isolated contacts for HVAC relay