or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Killark
Killark® FXCS-2A15 BOX CVR 2PB 1PL 3/4"
Custom_Product_Images_Illustration
Killark
Killark® FXCS-2A15 BOX CVR 2PB 1PL 3/4"
SKU950739
MFGR #FXCS-2A15
Your Cost: $1,223.70/ea
FXCS SERIES - ALUMINUM DEAD-END MOMENTARY CONTACT DOUBLE MINI PUSHBUTTON AND 120V PILOT LIGHT CONTROL STATION - FACTORY SEALED - GREENBUTTON WITH "START" NAMEPLATE - RED BUTTON WITH "STOP" NAMEPLATE - REDLENS WITH NAMEPLATE TO BE SPECIFIED - HUB SIZE 3/4 INCH - 1NO/1NCCONTACT RATING
FXCS SERIES - ALUMINUM DEAD-END MOMENTARY CONTACT DOUBLE MINI PUSHBUTTON AND 120V PILOT LIGHT CONTROL STATION - FACTORY SEALED - GREENBUTTON WITH "START" NAMEPLATE - RED BUTTON WITH "STOP" NAMEPLATE - REDLENS WITH NAMEPLATE TO BE SPECIFIED - HUB SIZE 3/4 INCH - 1NO/1NCCONTACT RATING
Action Momentary Actuator Pilot Light & Double Pushbutton Application SEAL-X Series is used to prevent the igniting of external hazardous atmospheres by the enclosed arcing devices in such areas as: hazardous locations due to the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers or flyings ARRA Compliant C Buy American Compliant C Catalog Number FXCS-2A15 Color Green-Red P.B., Red Light Contact Mode Momentary Country of Origin US Currency USD Dimensions 6-13/16 in H x 3-11/16 in W x 4-13/32 in D Enclosure Aluminum factory sealed dead-end splice box Environmental Conditions Hazardous locations EU RoHS Indicator C Gross Volume Per Pack 174.24 Gross Volume per Pack Metric 2855.22 Gross Volume UOM CI Gross Volume UOM Metric cm3 Gross Weight Per Pack 4.4000 lb Gross Weight per Pack Metric 2.00 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536509035 Height 4.38 in Height [Metric] 11.1252 cm Indicator Type LED Pilot Light Legend Start/Stop Length 6.63 in Length [Metric] 16.8402 cm Material Aluminum Number Of Poles 2 Operating Temperature -4 to 104 °F Returnable Y Series FXCS Size 6.63 in x 6 in x 4.38 in Standard UL, CSA Sub Brand SEAL-X Type Factory Sealed UNSPSC 39122216 UPC 11 78393620112 UPC 12 78393620112 Wattage 3 W Width 6.00 in Width [Metric] 15.2400 cm Stock Status NONSTOCK Brand Killark Manufacturer Hubbell Amperage Rating 10 A Contact Configuration 1-NO/1-NC NEMA Rating NEMA 3/7/9 Number of Operators 3 Voltage Rating 120/600 VAC SEAL-X Series is used to prevent the igniting of external hazardous atmospheres by the enclosed arcing devices in such areas as: hazardous locations due to the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers or flyings Killark SEAL-X Series Factory Sealed Control Stations provide control solutions in hazardous location areas to supply; START/STOP Motor Functions, LED Pilot Light Indications and more. Utilized in Class 1 Division 1 & 2, Class 1 Zone 1 & 2 areas where Type 3, 7 & 9 protection ratings are required for indoor and outdoor use. UL Listed and CSA Certified. Eliminates external sealing requirements Lower installation cost NEMA 3 weatherproof Color coded wiring with more wiring space for easier field installation Stainless steel captive screws for cover Ground boss for grounding in the splice box Device covers are cast copper-free aluminum alloy Pushbutton and pilot light bodies are copper-free aluminum Operating shaft in pushbuttons are stainless steel 60 A inrush at 120 VAC, 30 A inrush at 240 VAC, 15 A inrush at 480 VAC, 12 A inrush at 600 VAC, 6 A breaking at 120 VAC, 3 A breaking at 240 VAC, 1.5 A breaking at 480 VAC, 1.2 A breaking at 600 VAC, 10 A carrying at 120 VAC, 10 A carrying at 240 VAC, 10 A carrying at 480 VAC contact rating 0.025 A at 120 VAC pilot light, 0.55 A inrush at 125 VDC, 0.275 A inrush at 250 VDC, 0.55 A breaking at 125 VDC, 0.275 A breaking at 250 VDC, 2.5 A carrying at 125/250 VDC pushbutton
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Action | Momentary |
Actuator | Pilot Light & Double Pushbutton |
Application | SEAL-X Series is used to prevent the igniting of external hazardous atmospheres by the enclosed arcing devices in such areas as: hazardous locations due to the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers or flyings |
ARRA Compliant | C |
Buy American Compliant | C |
Catalog Number | FXCS-2A15 |
Color | Green-Red P.B., Red Light |
Contact Mode | Momentary |
Country of Origin | US |
Currency | USD |
Dimensions | 6-13/16 in H x 3-11/16 in W x 4-13/32 in D |
Enclosure | Aluminum factory sealed dead-end splice box |
Environmental Conditions | Hazardous locations |
EU RoHS Indicator | C |
Gross Volume Per Pack | 174.24 |
Gross Volume per Pack Metric | 2855.22 |
Gross Volume UOM | CI |
Gross Volume UOM Metric | cm3 |
Gross Weight Per Pack | 4.4000 lb |
Gross Weight per Pack Metric | 2.00 |
Gross Weight UOM Metric | kg |
Harmonization Tariff Schedule Code | 8536509035 |
Height | 4.38 in |
Height [Metric] | 11.1252 cm |
Indicator Type | LED Pilot Light |
Legend | Start/Stop |
Length | 6.63 in |
Length [Metric] | 16.8402 cm |
Material | Aluminum |
Number Of Poles | 2 |
Operating Temperature | -4 to 104 °F |
Returnable | Y |
Series | FXCS |
Size | 6.63 in x 6 in x 4.38 in |
Standard | UL, CSA |
Sub Brand | SEAL-X |
Type | Factory Sealed |
UNSPSC | 39122216 |
UPC 11 | 78393620112 |
UPC 12 | 78393620112 |
Wattage | 3 W |
Width | 6.00 in |
Width [Metric] | 15.2400 cm |
Stock Status | NONSTOCK |
Brand | Killark |
Manufacturer | Hubbell |
Amperage Rating | 10 A |
Contact Configuration | 1-NO/1-NC |
NEMA Rating | NEMA 3/7/9 |
Number of Operators | 3 |
Voltage Rating | 120/600 VAC |
SEAL-X Series is used to prevent the igniting of external hazardous atmospheres by the enclosed arcing devices in such areas as: hazardous locations due to the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers or flyings |
Killark SEAL-X Series Factory Sealed Control Stations provide control solutions in hazardous location areas to supply; START/STOP Motor Functions, LED Pilot Light Indications and more. Utilized in Class 1 Division 1 & 2, Class 1 Zone 1 & 2 areas where Type 3, 7 & 9 protection ratings are required for indoor and outdoor use. UL Listed and CSA Certified. |
Eliminates external sealing requirements |
Lower installation cost |
NEMA 3 weatherproof |
Color coded wiring with more wiring space for easier field installation |
Stainless steel captive screws for cover |
Ground boss for grounding in the splice box |
Device covers are cast copper-free aluminum alloy |
Pushbutton and pilot light bodies are copper-free aluminum |
Operating shaft in pushbuttons are stainless steel |
60 A inrush at 120 VAC, 30 A inrush at 240 VAC, 15 A inrush at 480 VAC, 12 A inrush at 600 VAC, 6 A breaking at 120 VAC, 3 A breaking at 240 VAC, 1.5 A breaking at 480 VAC, 1.2 A breaking at 600 VAC, 10 A carrying at 120 VAC, 10 A carrying at 240 VAC, 10 A carrying at 480 VAC contact rating |
0.025 A at 120 VAC pilot light, 0.55 A inrush at 125 VDC, 0.275 A inrush at 250 VDC, 0.55 A breaking at 125 VDC, 0.275 A breaking at 250 VDC, 2.5 A carrying at 125/250 VDC pushbutton |