Bussmann® NON-225 One time Fuse

Class H Fuses
174517 MFG #: NON-225
Bussmann
335.44000 / ea
  • Alternate Catalog Number: NON-225
  • Application: Ind Facilities & Factories - Facility: Safety and Security Systems
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: NON-225
  • Connection: Blade end x blade end
  • Country of Origin: MUL
  • Currency: USD
  • EU RoHS Indicator: C
  • Gross Weight Per Pack: 1.7700 lb
  • Gross Weight per Pack Metric: 0.75
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536100040
  • Height: 8.63 in
  • Height [Metric]: 21.9202 cm
  • Length: 2.60 in
  • Length [Metric]: 6.6040 cm
  • Size: 2.06 In Diameter X 8.63 In Length
  • Standard: CE Marked
  • Standards: UL 248-6, CSA Class 1421-01, File No. 53787, CE Certified, RoHS Compliant
  • Sub Brand: Bussmann Series
  • Type: Fuse
  • UNSPSC: 39121605
  • UPC 11: 05171230225
  • UPC 12: 051712302258
  • Width: 2.60 in
  • Width [Metric]: 6.6040 cm
  • Stock Status: NONSTOCK
  • Brand: Bussmann
  • Manufacturer: Eaton
  • Amperage Rating: 225 A
  • Class: H
  • Interrupt Rating: 10 kAIC at 250 Vac kA
  • Voltage Rating: 250 V
World?s leading supplier of fuses and fusible protection systems, Bussmann continues its 88-year history of blazing new trails of innovative technologies. Maker of the industry?s first truly global product line, each item is backed by an efficient worldwide network of distribution, customer service and technical support. Bussmann products include the most extensive circuit protection solutions approved for use in a variety of major standards: UL, CSA, IEC. . . Not to mention both European (DIN, British Standard) and North American styled fuses for a wide range of applications: industrial motor protection, power conversion, medium voltage, power distribution, telecommunications network equipment, electronics, and automotive.
QTY
  • Applications
  • Features
Ind Facilities & Factories - Facility: Safety and Security Systems
Non current limiting
Protect lighting, heating and other circuits not subject to temporary surges and where available short-circuit currents are relatively low
Non one-time fuses do not have any appreciable degree of time delay and thus should not be specified in circuits where large transients or motor overloads occur. use Bussmann advanced protection FUSETRON™ FRN-R or ultimate protection Low-Peak™ LPN-RK dual-element, time delay fuses
Use Bussmann advanced protection FUSETRON™ FRN-R or ultimate protection Low-Peak™ LPN-RK dual-element, time delay fuses
For general purpose circuits, size at A rating of circuit
For motor circuits, size at 300% to 400% according to the NEC® motor ampacity tables 430.247 to 430.250, per 430.6(A)(1)
10 kA VAC RMS symmetrical interrupt rating