Appleton® ELMFL90-75 Unilets™ ELM Explosionproof Conduit Elbow, 3/4 in Trade, 90 deg, Malleable Iron, Zinc Plated

Explosion Proof Conduit Elbows
17206 MFG #: ELMFL90-75
Appleton™
24.88000 / ea
  • Application: For Use With Threaded Rigid Metal Conduit And IMC
  • ARRA Compliant: Y
  • Buy American Compliant: N
  • Catalog Number: ELMFL90-75
  • Connection: Tapered MNPT X Tapered FNPT
  • Country of Origin: MX
  • Currency: USD
  • EU RoHS Indicator: C
  • Flexibility: Rigid And IMC
  • Gross Weight Per Pack: 0.4300 lb
  • Gross Weight per Pack Metric: 0.20
  • Gross Weight UOM Metric: kg
  • Height: 0.20 in
  • Height [Metric]: 5.0800 mm
  • Length: 6.30 in
  • Length [Metric]: 16.0020 cm
  • Series: ELM
  • Standard: UL 886, UL File Number E10444, CSA C22.2 No. 25 And 30, CSA 065181, UL Listed For Class I, Groups A, B, C, D; Class II, Groups E, F, G; And Class III
  • Standards: ARRA CompliantRoHS CompliantUL 886 File No. E10444CSA C22.2 No. 25/30CSA 065181, Class I, Groups A, B, C, D, Class II, Groups E, F, G and Class III
  • Sub Brand: UNILETS
  • Suitable For Use With: IMC/Threaded Rigid Metallic Conduit
  • Type: Dust-Ignitionproof Explosionproof
  • UNSPSC: 39131717
  • UPC 11: 78138129500
  • UPC 12: 781381295000
  • Width: 6.20 in
  • Width [Metric]: 15.7480 cm
  • Stock Status: NORMALLY STOCKED
  • Brand: Appleton™
  • Manufacturer: Appleton
  • Angle: 90 °
  • Finish: Zinc Electroplated
  • Material: Malleable Iron
  • Trade Size: 0.75 in
Appleton Group supplies conduit outlet boxes, pulling elbows and fittings to meet a wide range of classified location requirements. Most are available in a choice of triple coated malleable iron or epoxy powder-coated aluminum, providing exceptional durability and corrosion-resistance. We offer fittings with hub sizes from 1/2" through 4", with designs that facilitate pulling of even heavy, difficult to bend conductors.
QTY
  • Applications
  • Features
For Use With Threaded Rigid Metal Conduit And IMC
Explosionproof, dust-ignitionproof; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity
Explosion proof dust-ignitionproof
Smooth, rounded integral bushing in each hub protects conductor insulation
Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity
Tapered MNPT X Tapered FNPT connection
ASTM A47-77 malleable iron
Zinc electroplated
Class 1, Division 1 And 2, Groups C, D; Class II, Division 1 and 2, Groups E, F, G Class III