O-Z/Gedney DX-125 DX Series Expansion/Deflection Coupling, 1-1/4 in, For Use With Rigid Metal/IMC Conduit, Bronze

Conduit Expansion-Deflection Couplings
22124 MFG #: DX125
O-Z/Gedney
247.09000 / ea
  • Angle: 30 °
  • Application: For Rigid Conduit And IMC
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: DX125
  • Country of Origin: MX
  • Currency: USD
  • Dimensions: 3.13 in OD x 7.25 in L
  • Enclosure: NEMA 4
  • EU RoHS Indicator: N
  • Flexibility: RMC And IMC
  • Gross Weight Per Pack: 3.1500 lb
  • Gross Weight per Pack Metric: 1.43
  • Gross Weight UOM Metric: kg
  • Height: 2.00 in
  • Height [Metric]: 5.0800 cm
  • Length: 8.60 in
  • Length [Metric]: 21.8440 cm
  • Outside Diameter: 3.13 in
  • Standard: UL File Number E-11853, UL 514B, CSA C22.2 No.18.3, CSA 11584, NEMA : FB-1
  • Standards: UL ANSIUL 514BCSA C22.2 No. 18.3 StandardCSA 11584NEMA FB-14 StandardUL File No. E11853
  • Trade Size: 1.25 in
  • Type: Type DX Deflection/Expansion Fitting
  • UNSPSC: 39131707
  • UPC 11: 78312611531
  • UPC 12: 783126115314
  • Width: 6.70 in
  • Width [Metric]: 17.0180 cm
  • Stock Status: NORMALLY STOCKED
  • Brand: O-Z/Gedney
  • Manufacturer: O-Z/Gedney
  • Material: End Couplings: Bronze, Sleeve: Neoprene, Bands: Stainless Steel, Bonding Jumper: Tinned Copper Braid
  • Size: 1-1/4 in
  • Suitable For Use With: IMC/Rigid Metal Conduit
We offer a complete selection of steel, malleable iron and zinc fittings for rigid conduit and IMC. threaded and threadless, insulated or uninsulated non-insulated, watertight or general purpose, our conduit fittings, straps and accessories are available in all the sizes and configurations required to connect and support rigid conduit and to bond it to virtually any type of junction box or enclosure.
QTY
  • Applications
  • Features
For Rigid Conduit And IMC
Allow for a deflection of 30 DEG from normal alignment in any direction; Designed to withstand occasional vibration transmitted to conduit by rotating equipment or vehicular traffic; Internal bonding jumper has the capacity to carry ground fault currents equal to the conductor sizes required by UL and the NEC; May be used with PVC conduit by adding standard adapters in each end; Watertight, raintight, concretetight
Internal copper bonding jumper has the capacity to carry ground fault currents equal to the conductor sizes required by UL and the NEC
Watertight (NEMA 4), raintight and concretetight
May be used with PVC conduit by adding standard adapters in each end
Watertight (NEMA 4), Rain tight concretetight
Provide for a movement of 3/4 in from normal alignment in all directions
Allow for a deflection of 30 deg from normal alignment in any direction
Designed to withstand occasional vibration transmitted to conduit by rotating equipment or vehicular traffic
All other metal parts are malleable, ductile iron or stee