or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Appleton® GIB-75L-4AC GIB-L-AC Threaded Grounding Bushing, 14 to 4 AWG AC Cable, 3/4 in Trade, Malleable Iron, Electro-Plated Zinc
Custom_Product_Images_Illustration
Appleton® GIB-75L-4AC GIB-L-AC Threaded Grounding Bushing, 14 to 4 AWG AC Cable, 3/4 in Trade, Malleable Iron, Electro-Plated Zinc
SKU271468
MFGR #GIB-75L-4AC
Your Cost: $10.21/ea
O-Z/Gedney nonmetallic insulating bushings are used to protect wires and cables at entry and exit of threaded rigid conduit and IMC. O-Z/Gedney also has a plug to be used with metallic or nonmetallic bushings to prevent the entry of dirt or dust.
O-Z/Gedney nonmetallic insulating bushings are used to protect wires and cables at entry and exit of threaded rigid conduit and IMC. O-Z/Gedney also has a plug to be used with metallic or nonmetallic bushings to prevent the entry of dirt or dust.
Application For Use With Threaded Rigid Metal Conduit And IMC ARRA Compliant Y Buy American Compliant N Catalog Number GIB-75L-4AC Connection Threaded Country of Origin MX Currency USD EU RoHS Indicator C Gross Weight Per Pack 0.1800 lb Gross Weight per Pack Metric 0.04 Gross Weight UOM Metric kg Height 0.08 in Height [Metric] 2.0320 mm Length 9.00 in Length [Metric] 22.8600 cm Size 3/4 in Standard UL 467, E6581, CSA C22.2 No. 41, NEMA FB-1 Standards UL 467, E6581, CSA C22.2 No. 41, NEMA FB-1, RoHS Complaint Temperature Rating 150 °C Type Insulated Grounding Bushing With Aluminum Lay-In-Lug UNSPSC 39121312 UPC 11 78138109108 UPC 12 781381091084 Width 4.00 in Width [Metric] 10.1600 cm Stock Status NORMALLY STOCKED Brand Appleton™ Manufacturer Appleton Finish Zinc Electroplated Material Malleable Iron For Use With Threaded Rigid Metal Conduit And IMC Provides a compact means of grounding conduit through an insulated bushing; Can be used with a locknut to terminate conduit at an enclosure; Lug used to connect bonding jumper to a neutral bus bar; Insulating liner material is self-extinguishing; The plastic liner is tough, It resists corrosion, chemicals and temperature extremes, surface friction is so low that wires can be pulled with virtually no abrasion on the cable insulation; Lugs not sold separately; Fasten and ground threaded rigid, IMC metal conduit to an enclosure, copper or aluminum conductors Zinc plated malleable iron body, zinc plated steel clamping and set screw, tin plated aluminum or bronze/bright dip grounding lug Insulating liner material is self extinguishing Tough plastic liner won't chip, crack, swell or shrink; resists corrosion, chemicals and temperature extremes Low surface friction allows wires to be pulled with virtually no abrasion on the cable insulation Provides a compact means of grounding conduit through an insulated bushing Can be used with a locknut to terminate conduit at an enclosure Lug used to connect bonding jumper to a neutral bus bar Aluminum Lay-In-Lug Tin plated lug finish 14 AWG Solid - 4 AWG Standard cable size
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Application | For Use With Threaded Rigid Metal Conduit And IMC |
ARRA Compliant | Y |
Buy American Compliant | N |
Catalog Number | GIB-75L-4AC |
Connection | Threaded |
Country of Origin | MX |
Currency | USD |
EU RoHS Indicator | C |
Gross Weight Per Pack | 0.1800 lb |
Gross Weight per Pack Metric | 0.04 |
Gross Weight UOM Metric | kg |
Height | 0.08 in |
Height [Metric] | 2.0320 mm |
Length | 9.00 in |
Length [Metric] | 22.8600 cm |
Size | 3/4 in |
Standard | UL 467, E6581, CSA C22.2 No. 41, NEMA FB-1 |
Standards | UL 467, E6581, CSA C22.2 No. 41, NEMA FB-1, RoHS Complaint |
Temperature Rating | 150 °C |
Type | Insulated Grounding Bushing With Aluminum Lay-In-Lug |
UNSPSC | 39121312 |
UPC 11 | 78138109108 |
UPC 12 | 781381091084 |
Width | 4.00 in |
Width [Metric] | 10.1600 cm |
Stock Status | NORMALLY STOCKED |
Brand | Appleton™ |
Manufacturer | Appleton |
Finish | Zinc Electroplated |
Material | Malleable Iron |
For Use With Threaded Rigid Metal Conduit And IMC |
Provides a compact means of grounding conduit through an insulated bushing; Can be used with a locknut to terminate conduit at an enclosure; Lug used to connect bonding jumper to a neutral bus bar; Insulating liner material is self-extinguishing; The plastic liner is tough, It resists corrosion, chemicals and temperature extremes, surface friction is so low that wires can be pulled with virtually no abrasion on the cable insulation; Lugs not sold separately; Fasten and ground threaded rigid, IMC metal conduit to an enclosure, copper or aluminum conductors |
Zinc plated malleable iron body, zinc plated steel clamping and set screw, tin plated aluminum or bronze/bright dip grounding lug |
Insulating liner material is self extinguishing |
Tough plastic liner won't chip, crack, swell or shrink; resists corrosion, chemicals and temperature extremes |
Low surface friction allows wires to be pulled with virtually no abrasion on the cable insulation |
Provides a compact means of grounding conduit through an insulated bushing |
Can be used with a locknut to terminate conduit at an enclosure |
Lug used to connect bonding jumper to a neutral bus bar |
Aluminum Lay-In-Lug |
Tin plated lug finish |
14 AWG Solid - 4 AWG Standard cable size |