Schneider Electric BV4T013J TESYS Series, 600Y/347 VAC, 13 A
Custom_Product_Images_Illustration
Schneider Electric BV4T013J TESYS Series, 600Y/347 VAC, 13 A
SKUPDW~13594960
MFGR #BV4T013J
Price Not Available
Schneider Electric BV4T013J, TESYS Series, 600Y/347 VAC, 13 A, 50/60 Hz Frequency, Screw Connector Connection, IP40 Enclosure, -13 to 158 deg F, 6.38 in H x 3.19 in W x 4.57 in D Dimensions, Gray RAL 7016
Schneider Electric BV4T013J, TESYS Series, 600Y/347 VAC, 13 A, 50/60 Hz Frequency, Screw Connector Connection, IP40 Enclosure, -13 to 158 deg F, 6.38 in H x 3.19 in W x 4.57 in D Dimensions, Gray RAL 7016
Alternate Catalog Number BV4T013J Application For compact motor protection in conjunction with both the TeSys and Square D NEMA product families for motor control ARRA Compliant N Buy American Compliant N Catalog Number BV4T013J Country of Origin MX Currency USD EU RoHS Indicator Y Gross Volume Per Pack 278.12 Gross Volume per Pack Metric 4557.62 Gross Volume UOM CI Gross Volume UOM Metric cm3 Gross Weight Per Pack 3.3600 lb Gross Weight per Pack Metric 1.72 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536200020 Height 4.25 in Height [Metric] 10.9000 cm Length 8.62 in Length [Metric] 22.1000 cm Material Composition Declaration https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=474061119&lang=en-us Returnable Y Substitute Product Catalog Number GVAPL01 UNSPSC 39121601 UPC 11 606489811030 UPC 12 606489811030 Width 6.55 in Width [Metric] 16.8000 cm Brand Square D™ Manufacturer Schneider Electric For compact motor protection in conjunction with both the TeSys and Square D NEMA product families for motor control The TeSys BV4 motor circuit protector offers instantaneous trip short circuit protection for branch circuits for motor loads TeSys BV4 is a complementary magnetic-only offer to our GV4 product family using similar accessories It complies with NEC when installed based on UL listed control combinations having motor overload protection Coming in a variety of protection options to fit most applications with Standard and High fault short circuit current ratings See Type D combinations and details Designed for motor control applications 2A to115A up to 600Y/347 VAC Adjustable magnetic trip setting to meet full range of NEC requirements Common dimensions across line for consistent spacing requirements 2 protection levels at High Fault and Standard Fault options Auxiliary contacts for both Open/Close signaling as well as trip indication Auxiliary contacts for both Open/Close signaling as well as trip indication Voltage release options in both Shunt Trip and Undervoltage relay accessory Tamper-resistant cover seal provided for trip settings Variety of mounting options with 35mm and 75mm DIN or panel mount Extensive handle selection options with direct mount, front panel mount or side panel mount High performance performance level Short-circuit protection type 53 to 195 A 104 deg F (40 deg C) magnetic setting range 40000 cycles mechanical durability 1 alarm switch fault signalling contact, plug-in1 voltage release electrical remote tripping, plug-in1 auxiliary switch open/close contact, plug-in number of slots
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Alternate Catalog Number | BV4T013J |
| Application | For compact motor protection in conjunction with both the TeSys and Square D NEMA product families for motor control |
| ARRA Compliant | N |
| Buy American Compliant | N |
| Catalog Number | BV4T013J |
| Country of Origin | MX |
| Currency | USD |
| EU RoHS Indicator | Y |
| Gross Volume Per Pack | 278.12 |
| Gross Volume per Pack Metric | 4557.62 |
| Gross Volume UOM | CI |
| Gross Volume UOM Metric | cm3 |
| Gross Weight Per Pack | 3.3600 lb |
| Gross Weight per Pack Metric | 1.72 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 8536200020 |
| Height | 4.25 in |
| Height [Metric] | 10.9000 cm |
| Length | 8.62 in |
| Length [Metric] | 22.1000 cm |
| Material Composition Declaration | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=474061119&lang=en-us |
| Returnable | Y |
| Substitute Product Catalog Number | GVAPL01 |
| UNSPSC | 39121601 |
| UPC 11 | 606489811030 |
| UPC 12 | 606489811030 |
| Width | 6.55 in |
| Width [Metric] | 16.8000 cm |
| Brand | Square D™ |
| Manufacturer | Schneider Electric |
| For compact motor protection in conjunction with both the TeSys and Square D NEMA product families for motor control |
| The TeSys BV4 motor circuit protector offers instantaneous trip short circuit protection for branch circuits for motor loads |
| TeSys BV4 is a complementary magnetic-only offer to our GV4 product family using similar accessories |
| It complies with NEC when installed based on UL listed control combinations having motor overload protection |
| Coming in a variety of protection options to fit most applications with Standard and High fault short circuit current ratings |
| See Type D combinations and details |
| Designed for motor control applications 2A to115A up to 600Y/347 VAC |
| Adjustable magnetic trip setting to meet full range of NEC requirements |
| Common dimensions across line for consistent spacing requirements |
| 2 protection levels at High Fault and Standard Fault options |
| Auxiliary contacts for both Open/Close signaling as well as trip indication |
| Auxiliary contacts for both Open/Close signaling as well as trip indication |
| Voltage release options in both Shunt Trip and Undervoltage relay accessory |
| Tamper-resistant cover seal provided for trip settings |
| Variety of mounting options with 35mm and 75mm DIN or panel mount |
| Extensive handle selection options with direct mount, front panel mount or side panel mount |
| High performance performance level |
| Short-circuit protection type |
| 53 to 195 A 104 deg F (40 deg C) magnetic setting range |
| 40000 cycles mechanical durability |
| 1 alarm switch fault signalling contact, plug-in1 voltage release electrical remote tripping, plug-in1 auxiliary switch open/close contact, plug-in number of slots |