Square D™ QO220GFI Qwik-Gard® QO® Miniature Circuit Breaker, 120/240 VAC, 20 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip

Ground-Fault Circuit Breakers
33847 MFG #: QO220GFI
Square D™
413.00000 / ea
  • Alternate Catalog Number: QO220GFI
  • Application: Not rated
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: QO220GFI
  • Connection: PRESSURE PLATE #12 TO #8 AWG(AL) - #14 TO #8 AWG(CU)
  • Country of Origin: MX
  • Currency: USD
  • EU RoHS Indicator: Y
  • Gross Volume Per Pack: 41.58
  • Gross Volume per Pack Metric: 681.37
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 0.9500 lb
  • Gross Weight per Pack Metric: 430.92
  • Gross Weight UOM Metric: g
  • Harmonization Tariff Schedule Code: 8536200040
  • Height: 3.56 in
  • Height [Metric]: 9.1400 cm
  • Item Group: 00003
  • Length: 5.25 in
  • Length [Metric]: 13.4600 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=399021&lang=en-us
  • Operating Temperature: 40 °C
  • Phase: 1
  • Returnable: Y
  • Standard: UL LISTED - CSA CERTIFIED
  • Standards: UL 489, CSA 22.2 No. 144, RoHS Compliant
  • Sub Brand: QO
  • Substitute Product Catalog Number: QO612L100RB
  • Type: MINIATURE CIRCUIT BREAKER
  • UNSPSC: 39121603
  • UPC 11: 78590156299
  • UPC 12: 785901562993
  • Warranty Description: Contractual Warranty:18 months
  • Width: 2.18 in
  • Width [Metric]: 5.5900 cm
  • Stock Status: NORMALLY STOCKED
  • Brand: Square D™
  • Manufacturer: Schneider Electric
  • Amperage Rating: 20 A
  • Interrupt Rating: 10kA
  • Voltage Rating: 120/240 VAC
  • Number Of Poles: 2
Square D QO220GFI MINIATURE CIRCUIT BREAKER 120/240V 20A,1-Phase,10kA,120/240 Vac,20A,Ground Fault Protecting (Class A 6mA) Plug-On,Miniature Circuit Breaker,Pressure Plate #12 to #8 AWG(Al) - #14 to #8 AWG(Cu),Provides overload and short circuit protection Designed to offer Class A ground-fault protection for people,QO,UL Listed - CSA Certified
QTY
  • Applications
  • Features
Not rated
GROUND FAULT PROTECTING (CLASS A 6MA) PLUG-ON
Qwik-Gard® GFCIs provide the same branch circuit protection as standard QO® circuit breakers
They are longer than standard QO® circuit breakers and thus require more gutter space
Class A devices must trip at 6 mA of ground fault current and above and hold below 4 mA of ground fault current
For use with QO® load centers, NQOD panelboards/interiors and Speed-D® switchboard distribution panels
14 to 10 AWG copper, 14 to 8 AWG copper/aluminum wire
Common trip