or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Schneider Electric ATV212HD37N4 SPEEDDRIVE 380-480
Custom_Product_Images_Illustration
Schneider Electric ATV212HD37N4 SPEEDDRIVE 380-480
SKU715594
MFGR #ATV212HD37N4
Your Cost: $4,174.80/ea
Schneider Electric ATV212HD37N4 SPEEDDRIVE 380-480VAC 50HP,ATV212,3 phases,37kW,400/480 Vac 3-Phase,Altivar 212,Altivar 212,Maximum output voltage equal to input voltage 3-Phase,Modbus-LonWorks-METASYS N2-BACnet-APOGEE FLN,Modbus-LonWorks-METASYS N2-BACnet-APOGEE FLN,pumps and fans in HVAC,Open IP20,Size 7A,variable speed drive
Schneider Electric ATV212HD37N4 SPEEDDRIVE 380-480VAC 50HP,ATV212,3 phases,37kW,400/480 Vac 3-Phase,Altivar 212,Altivar 212,Maximum output voltage equal to input voltage 3-Phase,Modbus-LonWorks-METASYS N2-BACnet-APOGEE FLN,Modbus-LonWorks-METASYS N2-BACnet-APOGEE FLN,pumps and fans in HVAC,Open IP20,Size 7A,variable speed drive
Alternate Catalog Number ATV212HD37N4 Application Asynchronous motors;Pumps and fans in HVAC; ARRA Compliant N Buy American Compliant N Catalog Number ATV212HD37N4 Control +/- 10 OF NOMINAL SLIP 0.2 TN TO TN Country of Origin US Currency USD Display for DC bus energized 1 LED (red) Enclosure OPEN IP20 Enclosure Type IP20/IP21/IP41/Open Environmental Conditions -10-40 A°C WITHOUT)-40-50 A°C WITH DERATING FACTOR),CLASSES 3C1 IEC 60721-3-3-CLASSES 3S2 IEC 60721-3-3 EU RoHS Indicator Y Gross Volume Per Pack 13752.90 Gross Volume per Pack Metric 225368.77 Gross Weight Per Pack 51.8100 lb Gross Weight per Pack Metric 23.50 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8504404000 Height 45.0000 in Height [Metric] 45.0000 cm Input Voltage 380...480 V - 15...10 % Item Group 22158 Length 70.0000 in Length [Metric] 70.0000 cm Material Composition Declaration https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=61737732&lang=en-us Number Of Phases 3 Power Rating 976 W Returnable Y Series Altivar™ 212 Size 240 MM,244 MM,550 MM in Standard IP21 Sub Brand ATV212 Substitute Product Catalog Number VW3A21212 Type 3-Phase UNSPSC 39122001 UPC 11 78590195599 UPC 12 78590195599 Warranty Description Contractual Warranty:18 months Width [Metric] 38.5000 cm Stock Status NONSTOCK Brand Schneider Electric Manufacturer Schneider Electric Amperage Rating 79 A Depth 9.61 in Horsepower 50 hp Voltage Rating 380 to 480 VAC Width 38.5000 in Asynchronous motors;Pumps and fans in HVAC; VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14;L1/R, L2/S, L3/T terminal 50-50 mm² / AWG 1/0;Flux vector control without sensor, standard;voltage/frequency ratio, 5 points;voltage/frequency ratio, 2 points;voltage/frequency ratio - Energy Saving, quadratic U/f;voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo);Overheating protection drive;line supply undervoltage drive;against input phase loss drive;thermal protection motor;motor phase break motor;with PTC probes motor;thermal power stage drive;short-circuit between motor phases drive;input phase breaks drive;overcurrent between output phases and earth drive;overvoltages on the DC bus drive;break on the control circuit drive;against exceeding limit speed drive;line supply overvoltage and undervoltage drive;Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection;internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection 79 A at 380/460 VAC Lower maintenance costs-reduce the mechanical stress on belts, piping and ductwork and eliminate valve or inlet guide vane maintenance Reduced harmonics embedded reduced harmonic technology is equivalent to installing a 3% line reactor saving panel space and reducing component and wiring costs Reduce installation costs embedded technology reduces input currents which allows a cost reduction in wire size, short circuit protection devices and enclosure size Improve operating efficiency embedded technology reduces input currents which improves operating efficiency by 10% in many installations Achieve 12 to 24 month payback for AC drives installed on typical pump or fan applications
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Alternate Catalog Number | ATV212HD37N4 |
Application | Asynchronous motors;Pumps and fans in HVAC; |
ARRA Compliant | N |
Buy American Compliant | N |
Catalog Number | ATV212HD37N4 |
Control | +/- 10 OF NOMINAL SLIP 0.2 TN TO TN |
Country of Origin | US |
Currency | USD |
Display | for DC bus energized 1 LED (red) |
Enclosure | OPEN IP20 |
Enclosure Type | IP20/IP21/IP41/Open |
Environmental Conditions | -10-40 A°C WITHOUT)-40-50 A°C WITH DERATING FACTOR),CLASSES 3C1 IEC 60721-3-3-CLASSES 3S2 IEC 60721-3-3 |
EU RoHS Indicator | Y |
Gross Volume Per Pack | 13752.90 |
Gross Volume per Pack Metric | 225368.77 |
Gross Weight Per Pack | 51.8100 lb |
Gross Weight per Pack Metric | 23.50 |
Gross Weight UOM Metric | kg |
Harmonization Tariff Schedule Code | 8504404000 |
Height | 45.0000 in |
Height [Metric] | 45.0000 cm |
Input Voltage | 380...480 V - 15...10 % |
Item Group | 22158 |
Length | 70.0000 in |
Length [Metric] | 70.0000 cm |
Material Composition Declaration | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=61737732&lang=en-us |
Number Of Phases | 3 |
Power Rating | 976 W |
Returnable | Y |
Series | Altivar™ 212 |
Size | 240 MM,244 MM,550 MM in |
Standard | IP21 |
Sub Brand | ATV212 |
Substitute Product Catalog Number | VW3A21212 |
Type | 3-Phase |
UNSPSC | 39122001 |
UPC 11 | 78590195599 |
UPC 12 | 78590195599 |
Warranty Description | Contractual Warranty:18 months |
Width [Metric] | 38.5000 cm |
Stock Status | NONSTOCK |
Brand | Schneider Electric |
Manufacturer | Schneider Electric |
Amperage Rating | 79 A |
Depth | 9.61 in |
Horsepower | 50 hp |
Voltage Rating | 380 to 480 VAC |
Width | 38.5000 in |
Asynchronous motors;Pumps and fans in HVAC; |
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14;L1/R, L2/S, L3/T terminal 50-50 mm² / AWG 1/0;Flux vector control without sensor, standard;voltage/frequency ratio, 5 points;voltage/frequency ratio, 2 points;voltage/frequency ratio - Energy Saving, quadratic U/f;voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo);Overheating protection drive;line supply undervoltage drive;against input phase loss drive;thermal protection motor;motor phase break motor;with PTC probes motor;thermal power stage drive;short-circuit between motor phases drive;input phase breaks drive;overcurrent between output phases and earth drive;overvoltages on the DC bus drive;break on the control circuit drive;against exceeding limit speed drive;line supply overvoltage and undervoltage drive;Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection;internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection |
79 A at 380/460 VAC |
Lower maintenance costs-reduce the mechanical stress on belts, piping and ductwork and eliminate valve or inlet guide vane maintenance |
Reduced harmonics embedded reduced harmonic technology is equivalent to installing a 3% line reactor saving panel space and reducing component and wiring costs |
Reduce installation costs embedded technology reduces input currents which allows a cost reduction in wire size, short circuit protection devices and enclosure size |
Improve operating efficiency embedded technology reduces input currents which improves operating efficiency by 10% in many installations |
Achieve 12 to 24 month payback for AC drives installed on typical pump or fan applications |