Rees 04954-204 Cable Operated Switc

Rees 04954-204 Cable Operated Switc

SKU402829

MFGR #04954204

$/ea
Rees; Cable Operated Switch; Slack Cable; Contact Configuration: 2 NO + 2 NC, (2) NO/NC Each End; Material: High Quality Die-Cast Aluminum Housing; Size: 10.760 IN Length X 3.900 IN Height; Operating Temperature: 0 To +55 DEG C; Environmental Conditions: -40 To +85 DEG C Storage Temperature; Note: Operating Temperatures At 0 DEG C Are Based On The Absence Of Freezing Moisture And Liquids; Normal Potential: 110 - 120 VAC, 220 - 240 VAC, 440 - 480 VAC, 550 - 600 VAC At Power Factor 0.35 Or Less; 115 - 125 VDC, 230 - 250 VDC At Inductive Loads As Specified In Section 125 Of Industrial Control Devices, Controllers And Assemblies, ANSI/NEMA ICS 2-1988; Normal Current: 6, 3, 1.5, 1.2, 2.2, 1.1 AMP; Inrush Current: 60, 30, 15, 12 AMP; Trip Force: 25 LB/End; Operating Force Between 10 Ft Supports: 6 LB; Mechanical Life: 150000 Operations; Wire Size: 14/2 AWG Stranded; Flag End Replaceable: Both; Nema: 4X (Indoor); Color: Yellow Housing; Reset Type: Manual; Finish: Powder Coated Painted Housing; Conduit Openings: (2) 3/4 IN NPT; Ip: 66; Includes: Double Flag Indicator(S) Or Latch Plates; Contact Finish: Gold Plated
Rees; Cable Operated Switch; Slack Cable; Contact Configuration: 2 NO + 2 NC, (2) NO/NC Each End; Material: High Quality Die-Cast Aluminum Housing; Size: 10.760 IN Length X 3.900 IN Height; Operating Temperature: 0 To +55 DEG C; Environmental Conditions: -40 To +85 DEG C Storage Temperature; Note: Operating Temperatures At 0 DEG C Are Based On The Absence Of Freezing Moisture And Liquids; Normal Potential: 110 - 120 VAC, 220 - 240 VAC, 440 - 480 VAC, 550 - 600 VAC At Power Factor 0.35 Or Less; 115 - 125 VDC, 230 - 250 VDC At Inductive Loads As Specified In Section 125 Of Industrial Control Devices, Controllers And Assemblies, ANSI/NEMA ICS 2-1988; Normal Current: 6, 3, 1.5, 1.2, 2.2, 1.1 AMP; Inrush Current: 60, 30, 15, 12 AMP; Trip Force: 25 LB/End; Operating Force Between 10 Ft Supports: 6 LB; Mechanical Life: 150000 Operations; Wire Size: 14/2 AWG Stranded; Flag End Replaceable: Both; Nema: 4X (Indoor); Color: Yellow Housing; Reset Type: Manual; Finish: Powder Coated Painted Housing; Conduit Openings: (2) 3/4 IN NPT; Ip: 66; Includes: Double Flag Indicator(S) Or Latch Plates; Contact Finish: Gold Plated

Country of Origin

USA

Gross Weight Per Pack

1 lb

Stock Status

NONSTOCK

UNSPSC

39122205