Pass & Seymour® TradeMaster® 2095LA Duplex GFCI Receptacle, 125 VAC, 20 A, 2 Poles, 3 Wires, Light Almond
Pass & Seymour® TradeMaster® 2095LA Duplex GFCI Receptacle, 125 VAC, 20 A, 2 Poles, 3 Wires, Light Almond
SKUPDW~3377210
MFGR #2095LA
$/ea
Pass & Seymour® TradeMaster Duplex GFCI Receptacle, 125 VAC, 20 A, 1 hp, 60 Hz, 2 Poles, 3 Wires, NEMA 5-20R, Specification Grade, -35 to 66 deg C, Back and Side Wired Terminal, Thermoplastic, Light Almond, 4.2 in H x 1.72 in W x 0.98 in D
Pass & Seymour® TradeMaster Duplex GFCI Receptacle, 125 VAC, 20 A, 1 hp, 60 Hz, 2 Poles, 3 Wires, NEMA 5-20R, Specification Grade, -35 to 66 deg C, Back and Side Wired Terminal, Thermoplastic, Light Almond, 4.2 in H x 1.72 in W x 0.98 in D
Catalog Number 2095LA Country of Origin CN Dimensions 4.2 in H x 1.72 in W x 0.98 in D Frequency Rating 60 Hz Grade Specification Gross Weight Per Pack 1 lb Horsepower 1 hp Material Thermoplastic NEMA Rating NEMA 5-20R Number Of Poles 2 Standards cULus Listed, UL943 C22.2 No. 144, UL498 C22.2 No. 42 Certified, FSUL WC596, NEMA WD-1 and WD-6 Temperature Rating -35 to 66 °C Terminal Type Back/Side Wired UNSPSC 39121633 UPC 11 78500742415 Stock Status NONSTOCK Brand Pass & Seymour® Manufacturer Legrand Amperage Rating 20 A Color Light Almond Number of Wires 3 Voltage Rating 125 VAC Safelock protection, auto ground, trip light indicator Class A rated GFCI 5 +/-1 mA trio threshold, 20 A feed-thru capacity SafeLock protection if critical components are damaged and ground fault protection is lost, power to receptacle is disconnected Trip indicator light (red LED) Feed-thru wiring configuration allows GFCI to protect downstream receptacles Prevents line-load reversal miswire no power to the face or downstream receptacles if wired incorrectly Exceeds UL943 voltage surge requirements, survives 100x the required UL 3 kA/6 kV voltage surge test cycles Side or internal screw-pressure-plate back wire with 10 to 14 AWG solid or stranded copper wire High-impact-resistant thermoplastic construction Ground screw has a back wire clamp for easy installation, two back wire holes per terminal 10 kA short circuit rating Mounting screws are shipped captive in the device and wallplate for easier installation Extra-long strap, button colors match the device face, dual-direction test and reset buttons Withstands 1500 V minimum dielectric, 4 to 6 mA trip level 0.025 second nominal trip time 95% maximum humidity, V-2 per UL-94 flammability rating
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
| Catalog Number | 2095LA |
| Country of Origin | CN |
| Dimensions | 4.2 in H x 1.72 in W x 0.98 in D |
| Frequency Rating | 60 Hz |
| Grade | Specification |
| Gross Weight Per Pack | 1 lb |
| Horsepower | 1 hp |
| Material | Thermoplastic |
| NEMA Rating | NEMA 5-20R |
| Number Of Poles | 2 |
| Standards | cULus Listed, UL943 C22.2 No. 144, UL498 C22.2 No. 42 Certified, FSUL WC596, NEMA WD-1 and WD-6 |
| Temperature Rating | -35 to 66 °C |
| Terminal Type | Back/Side Wired |
| UNSPSC | 39121633 |
| UPC 11 | 78500742415 |
| Stock Status | NONSTOCK |
| Brand | Pass & Seymour® |
| Manufacturer | Legrand |
| Amperage Rating | 20 A |
| Color | Light Almond |
| Number of Wires | 3 |
| Voltage Rating | 125 VAC |
| Safelock protection, auto ground, trip light indicator |
| Class A rated GFCI |
| 5 +/-1 mA trio threshold, 20 A feed-thru capacity |
| SafeLock protection if critical components are damaged and ground fault protection is lost, power to receptacle is disconnected |
| Trip indicator light (red LED) |
| Feed-thru wiring configuration allows GFCI to protect downstream receptacles |
| Prevents line-load reversal miswire no power to the face or downstream receptacles if wired incorrectly |
| Exceeds UL943 voltage surge requirements, survives 100x the required UL 3 kA/6 kV voltage surge test cycles |
| Side or internal screw-pressure-plate back wire with 10 to 14 AWG solid or stranded copper wire |
| High-impact-resistant thermoplastic construction |
| Ground screw has a back wire clamp for easy installation, two back wire holes per terminal |
| 10 kA short circuit rating |
| Mounting screws are shipped captive in the device and wallplate for easier installation |
| Extra-long strap, button colors match the device face, dual-direction test and reset buttons |
| Withstands 1500 V minimum dielectric, 4 to 6 mA trip level |
| 0.025 second nominal trip time |
| 95% maximum humidity, V-2 per UL-94 flammability rating |