or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Pass & Seymour® 2095TRWRW Class A Weather Resistant Duplex GFCI Receptacle, 125 VAC, 20 A, 2 Poles, 3 Wires, White
Pass & Seymour® 2095TRWRW Class A Weather Resistant Duplex GFCI Receptacle, 125 VAC, 20 A, 2 Poles, 3 Wires, White
SKUPDW~4668830
MFGR #2095TRWRW
$/ea
Pass & Seymour® Duplex GFCI Receptacle, Class A Weather Resistant, 125 VAC, 20 A, 1 hp, 60 Hz, 2 Poles, 3 Wires, NEMA 5-20R, Specification Grade, -35 to 66 deg C, Back and Side Wired Terminal, Thermoplastic, White, 4.2 in H x 1.72 in W x 1.13 in D
Pass & Seymour® Duplex GFCI Receptacle, Class A Weather Resistant, 125 VAC, 20 A, 1 hp, 60 Hz, 2 Poles, 3 Wires, NEMA 5-20R, Specification Grade, -35 to 66 deg C, Back and Side Wired Terminal, Thermoplastic, White, 4.2 in H x 1.72 in W x 1.13 in D
Catalog Number 2095TRWRW Country of Origin CN Dimensions 4.2 in H x 1.72 in W x 1.13 in D Frequency Rating 60 Hz Grade Specification Gross Weight Per Pack 0.4000 lb Horsepower 1 hp Material Thermoplastic NEMA Rating NEMA 5-20R Number Of Poles 2 Standards cULus Listed, UL943 C22.2 No. 144, UL498 C22.2 No. 42 Certified, FSUL WC596, NEMA WD-1 and WD-6 Temperature Rating -35 to 66 °C Terminal Type Back/Side Wired Type Class A Weather-Resistant UNSPSC 39121633 UPC 11 78500724088 Stock Status NONSTOCK Brand Pass & Seymour® Manufacturer Legrand Amperage Rating 20 A Color White Number of Wires 3 Voltage Rating 125 VAC Weather resistant, tamper resistant, protects child, safelock protection Protects children patented shutter system helps prevent improper insertion of foreign objects Meets national electrical code tamper-resistant requirements SafeLock protection if critical components are damaged and ground fault protection is lost, power to receptacle is disconnected Feed-thru wiring configuration allows GFCI to protect downstream receptacles Prevents line-load reversal miswire no power to the face or downstream receptacles if wired incorrectly Exceeds UL943 voltage surge requirements, survives 100x the required UL 3 kA/6 kV voltage surge test cycles Trip indicator light (red LED) Side or internal screw-pressure-plate back wire with 10 to 14 AWG solid or stranded copper wire Two back wire holes per terminal Ground screw has a back wire clamp for easy installation 10 kA short circuit rating Mounting screws are shipped captive in the device and wallplate for easier installation Extra-long nickel post-plated steel mounting strap, listed to the weather-resistant supplement of UL498 meeting demanding UL requirements Button colors match the device face, tamper-resistant meets national electrical code tamper-resistant requirements Weather-resistant meets national electrical code weather-resistant requirements Withstands 1500V minimum dielectric, 4 to 6 mA trip level 0.025 second nominal trip time 95% maximum humidity, V-2 per UL-94 flammability rating Nylon 66 face and body, 0.03 in brass contacts, 0.05 in zinc plated steel mounting straps, steel # 8-32 terminal screws Steel hex head grounding screw, zinc plated steel flat head mounting screws, nylon test/reset buttons, brass alloy C260 auto-ground clip
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
| Catalog Number | 2095TRWRW |
| Country of Origin | CN |
| Dimensions | 4.2 in H x 1.72 in W x 1.13 in D |
| Frequency Rating | 60 Hz |
| Grade | Specification |
| Gross Weight Per Pack | 0.4000 lb |
| Horsepower | 1 hp |
| Material | Thermoplastic |
| NEMA Rating | NEMA 5-20R |
| Number Of Poles | 2 |
| Standards | cULus Listed, UL943 C22.2 No. 144, UL498 C22.2 No. 42 Certified, FSUL WC596, NEMA WD-1 and WD-6 |
| Temperature Rating | -35 to 66 °C |
| Terminal Type | Back/Side Wired |
| Type | Class A Weather-Resistant |
| UNSPSC | 39121633 |
| UPC 11 | 78500724088 |
| Stock Status | NONSTOCK |
| Brand | Pass & Seymour® |
| Manufacturer | Legrand |
| Amperage Rating | 20 A |
| Color | White |
| Number of Wires | 3 |
| Voltage Rating | 125 VAC |
| Weather resistant, tamper resistant, protects child, safelock protection |
| Protects children patented shutter system helps prevent improper insertion of foreign objects |
| Meets national electrical code tamper-resistant requirements |
| SafeLock protection if critical components are damaged and ground fault protection is lost, power to receptacle is disconnected |
| Feed-thru wiring configuration allows GFCI to protect downstream receptacles |
| Prevents line-load reversal miswire no power to the face or downstream receptacles if wired incorrectly |
| Exceeds UL943 voltage surge requirements, survives 100x the required UL 3 kA/6 kV voltage surge test cycles |
| Trip indicator light (red LED) |
| Side or internal screw-pressure-plate back wire with 10 to 14 AWG solid or stranded copper wire |
| Two back wire holes per terminal |
| Ground screw has a back wire clamp for easy installation |
| 10 kA short circuit rating |
| Mounting screws are shipped captive in the device and wallplate for easier installation |
| Extra-long nickel post-plated steel mounting strap, listed to the weather-resistant supplement of UL498 meeting demanding UL requirements |
| Button colors match the device face, tamper-resistant meets national electrical code tamper-resistant requirements |
| Weather-resistant meets national electrical code weather-resistant requirements |
| Withstands 1500V minimum dielectric, 4 to 6 mA trip level |
| 0.025 second nominal trip time |
| 95% maximum humidity, V-2 per UL-94 flammability rating |
| Nylon 66 face and body, 0.03 in brass contacts, 0.05 in zinc plated steel mounting straps, steel # 8-32 terminal screws |
| Steel hex head grounding screw, zinc plated steel flat head mounting screws, nylon test/reset buttons, brass alloy C260 auto-ground clip |