or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Killark
KillarkĀ® FXCS-5S3R6G BOX CVR 3POS STAND
Custom_Product_Images_Illustration
Killark
KillarkĀ® FXCS-5S3R6G BOX CVR 3POS STAND
SKU948156
MFGR #FXCS-5S3R6G
$/ea
FXCS SERIES - ALUMINUM FEED-THRU SPRING RETURNED 3-POSITION SELECTORSWITCH CONTROL STATION - FACTORY SEALED - SPRING RETURN TO CENTER FROMLEFT- "HAND - OFF - AUTO"/BLANK NAMEPLATE - HUB SIZE 3/4 INCH - 2NOCONTACT
FXCS SERIES - ALUMINUM FEED-THRU SPRING RETURNED 3-POSITION SELECTORSWITCH CONTROL STATION - FACTORY SEALED - SPRING RETURN TO CENTER FROMLEFT- "HAND - OFF - AUTO"/BLANK NAMEPLATE - HUB SIZE 3/4 INCH - 2NOCONTACT
SEAL-X Series is used to prevent the igniting of external hazardous atmospheres by the enclosed arcing devices in such areas as: hazardous locations due to the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers or flyings Killark SEAL-X Series Factory Sealed Control Stations provide control solutions in hazardous location areas to supply; START/STOP Motor Functions, LED Pilot Light Indications and more. Utilized in Class 1 Division 1 & 2, Class 1 Zone 1 & 2 areas where Type 3, 7 & 9 protection ratings are required for indoor and outdoor use. UL Listed and CSA Certified. 0.55 A at 125 VDC, 0.275 A at 250 VDC inrush, 0.55 A at 125 VDC, 0.275 A at 250 VDC breaking, 2.5 A at 125/250 VDC carrying Elimination of external sealing requirements Lower installation cost NEMA 3 weatherproof Color coded wiring with more wiring space for easier field installation 60 A at 120 VAC, 30 A at 240 VAC, 15 A at 480 VAC, 12 A at 600 VAC inrush, 6 A at 120 VAC, 3 A at 240 VAC, 1.5 A at 480 VAC, 1.2 A at 600 VAC breaking, 10 A at 120 VAC, 10 A at 240 VAC and 10 A at 480 VAC carrying Device covers are cast copper-free aluminum alloy
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Action | Momentary Left |
| Actuator | 3 Position Key Selector Switch |
| Application | SEAL-X Series is used to prevent the igniting of external hazardous atmospheres by the enclosed arcing devices in such areas as: hazardous locations due to the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers or flyings |
| ARRA Compliant | C |
| Buy American Compliant | C |
| Catalog Number | FXCS-5S3R6G |
| Color | Black |
| Contact Mode | Spring Return |
| Country of Origin | US |
| Currency | USD |
| Dimensions | 6-13/16 in H x 3-11/16 in W x 4-13/32 in D |
| Enclosure | Aluminum factory sealed feed-thru splice box |
| Environmental Conditions | Hazardous locations |
| EU RoHS Indicator | C |
| Gross Volume Per Pack | 174.24 |
| Gross Volume per Pack Metric | 2855.22 |
| Gross Volume UOM | CI |
| Gross Volume UOM Metric | cm3 |
| Gross Weight Per Pack | 4.5000 lb |
| Gross Weight per Pack Metric | 2.04 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 8536509025 |
| Height | 4.38 in |
| Height [Metric] | 11.1252 cm |
| Legend | HAND/OFF/AUTO |
| Length | 6.63 in |
| Length [Metric] | 16.8402 cm |
| Material | Copper-Free Aluminum |
| Number Of Poles | 1 |
| Returnable | Y |
| Series | FXCS SEAL-X⢠|
| Size | 6.63 in x 6 in x 4.38 in |
| Standard | UL, CSA |
| Standards | ARRA CompliantBuy American Act CompliantRoHS CompliantUL File No. E53360/E12379CSA File No. LR11714Class I Divisions 1 and 2 Groups C, DClass I Zone 1 and 2 Groups IIB, IIAClass II Divisions 1 and 2 Groups E, F, GClass III |
| Sub Brand | SEAL-X |
| Type | Factory Sealed |
| UNSPSC | 39122216 |
| UPC 11 | 78393620257 |
| UPC 12 | 78393620257 |
| Width | 6.00 in |
| Width [Metric] | 15.2400 cm |
| Stock Status | NONSTOCK |
| Brand | Killark |
| Manufacturer | Hubbell |
| Amperage Rating | 10 A |
| Contact Configuration | 2-NO |
| NEMA Rating | NEMA 3/7CD/9EFG |
| Voltage Rating | 600 VAC |
| SEAL-X Series is used to prevent the igniting of external hazardous atmospheres by the enclosed arcing devices in such areas as: hazardous locations due to the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers or flyings |
| Killark SEAL-X Series Factory Sealed Control Stations provide control solutions in hazardous location areas to supply; START/STOP Motor Functions, LED Pilot Light Indications and more. Utilized in Class 1 Division 1 & 2, Class 1 Zone 1 & 2 areas where Type 3, 7 & 9 protection ratings are required for indoor and outdoor use. UL Listed and CSA Certified. |
| 0.55 A at 125 VDC, 0.275 A at 250 VDC inrush, 0.55 A at 125 VDC, 0.275 A at 250 VDC breaking, 2.5 A at 125/250 VDC carrying |
| Elimination of external sealing requirements |
| Lower installation cost |
| NEMA 3 weatherproof |
| Color coded wiring with more wiring space for easier field installation |
| 60 A at 120 VAC, 30 A at 240 VAC, 15 A at 480 VAC, 12 A at 600 VAC inrush, 6 A at 120 VAC, 3 A at 240 VAC, 1.5 A at 480 VAC, 1.2 A at 600 VAC breaking, 10 A at 120 VAC, 10 A at 240 VAC and 10 A at 480 VAC carrying |
| Device covers are cast copper-free aluminum alloy |