Hubbell® Circuit Guard® GFHW530 Heavy Duty Hard Wired GFCI, 250 VAC, 30 A, NEMA 4X Enclosure, Valox®
Custom_Product_Images_Illustration
Hubbell® Circuit Guard® GFHW530 Heavy Duty Hard Wired GFCI, 250 VAC, 30 A, NEMA 4X Enclosure, Valox®
SKU386266
MFGR #GFHW530
Your Cost: $919.13/ea
Hubbell® Circuit Guard® Hard Wired GFCI, Heavy Duty, 250 VAC, 30 A, 60 Hz, -30 to 66 deg C, 0.025 sec Response, NEMA 4X Enclosure, Valox®, Gray, 4.8 in L x 3.37 in W x 2.64 in D
Hubbell® Circuit Guard® Hard Wired GFCI, Heavy Duty, 250 VAC, 30 A, 60 Hz, -30 to 66 deg C, 0.025 sec Response, NEMA 4X Enclosure, Valox®, Gray, 4.8 in L x 3.37 in W x 2.64 in D
Application Wire Into Circuit ARRA Compliant C Buy American Compliant C Catalog Number GFHW530 Color Black Conductor Material Copper Conductor Size #10 AWG Construction Fabricated Country of Origin US Currency USD Dimensions 24 in L EU RoHS Indicator N Gross Weight Per Pack 2.2000 lb Gross Weight per Pack Metric 1.02 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536308000 Height 4.20 in Height [Metric] 10.6680 cm Insulation Material Thermoplastic Length 10.60 in Length [Metric] 26.9240 cm Number Of Conductors 4 Returnable Y Standard UL LISTED Standards ARRA CompliantBuy American Act CompliantcULus ListedUL 943 Strands Multi Sub Brand Hard Wired 30A GFCI Temperature Rating -35 Degrees C to 66 Degrees C (-30 Degrees F to 150 Degrees F) °F Type Hard Wired UNSPSC 26121536 UPC 11 78358552106 UPC 12 783585521060 Width 4.20 in Width [Metric] 10.6680 cm Stock Status NONSTOCK Brand Hubbell Wiring Device-Kellems Manufacturer Hubbell Amperage Rating 30 A Enclosure NEMA 4X Material Thermoplastic Voltage Rating 3 Phase 250 VAC Wire Into Circuit Manual Set- No Alarm Requires the GFCI to be manually reset for use by pressing the reset button after the loss of primary power Must be also manually reset after a ground fault condition Manual reset is ideal for applications where operator injury might occur if equipment were to restart after a power failure Offers a 4 to 6 mA trip level Green light illuminates when unit has power and no ground fault is present Red light begins blinking when a ground fault is detected and the output power is interrupted Double insulated switch interface, electromagnetic latching mechanism Industrial grade design Black background with yellow lettering label color Gray with black cover unit 10 AWG, 24 in long wire lead Class A GFCI, 10000 cycles (6000 with load and 4000 without load) life Green light on power on, red blinking light plus optional audible alarm power off indicator
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Application | Wire Into Circuit |
ARRA Compliant | C |
Buy American Compliant | C |
Catalog Number | GFHW530 |
Color | Black |
Conductor Material | Copper |
Conductor Size | #10 AWG |
Construction | Fabricated |
Country of Origin | US |
Currency | USD |
Dimensions | 24 in L |
EU RoHS Indicator | N |
Gross Weight Per Pack | 2.2000 lb |
Gross Weight per Pack Metric | 1.02 |
Gross Weight UOM Metric | kg |
Harmonization Tariff Schedule Code | 8536308000 |
Height | 4.20 in |
Height [Metric] | 10.6680 cm |
Insulation Material | Thermoplastic |
Length | 10.60 in |
Length [Metric] | 26.9240 cm |
Number Of Conductors | 4 |
Returnable | Y |
Standard | UL LISTED |
Standards | ARRA CompliantBuy American Act CompliantcULus ListedUL 943 |
Strands | Multi |
Sub Brand | Hard Wired 30A GFCI |
Temperature Rating | -35 Degrees C to 66 Degrees C (-30 Degrees F to 150 Degrees F) °F |
Type | Hard Wired |
UNSPSC | 26121536 |
UPC 11 | 78358552106 |
UPC 12 | 783585521060 |
Width | 4.20 in |
Width [Metric] | 10.6680 cm |
Stock Status | NONSTOCK |
Brand | Hubbell Wiring Device-Kellems |
Manufacturer | Hubbell |
Amperage Rating | 30 A |
Enclosure | NEMA 4X |
Material | Thermoplastic |
Voltage Rating | 3 Phase 250 VAC |
Wire Into Circuit |
Manual Set- No Alarm |
Requires the GFCI to be manually reset for use by pressing the reset button after the loss of primary power |
Must be also manually reset after a ground fault condition |
Manual reset is ideal for applications where operator injury might occur if equipment were to restart after a power failure |
Offers a 4 to 6 mA trip level |
Green light illuminates when unit has power and no ground fault is present |
Red light begins blinking when a ground fault is detected and the output power is interrupted |
Double insulated switch interface, electromagnetic latching mechanism |
Industrial grade design |
Black background with yellow lettering label color |
Gray with black cover unit |
10 AWG, 24 in long wire lead |
Class A GFCI, 10000 cycles (6000 with load and 4000 without load) life |
Green light on power on, red blinking light plus optional audible alarm power off indicator |