Hubbell® Circuit Guard® GFHW23005 Heavy Duty Hard Wired GFCI, 250 VAC, 30 A, NEMA 4X Enclosure, Valox®
Custom_Product_Images_Illustration
Hubbell Wiring Device-Kellems
Hubbell® Circuit Guard® GFHW23005 Heavy Duty Hard Wired GFCI, 250 VAC, 30 A, NEMA 4X Enclosure, Valox®
SKU221396
MFGR #GFHW23005
$/ea
Hubbell® Circuit Guard® Hard Wired GFCI, Heavy Duty, 250 VAC, 30 A, 60 Hz, -30 to 66 deg C, 0.025 sec Response, NEMA 4X Enclosure, Valox®, Gray, 4.8 in L x 3.37 in W x 2.64 in D
Hubbell® Circuit Guard® Hard Wired GFCI, Heavy Duty, 250 VAC, 30 A, 60 Hz, -30 to 66 deg C, 0.025 sec Response, NEMA 4X Enclosure, Valox®, Gray, 4.8 in L x 3.37 in W x 2.64 in D
Amperage Rating 30 A Application Wire Into Circuit ARRA Compliant C Brand Hubbell Wiring Device-Kellems Buy American Compliant C Catalog Number GFHW23005 Color Black Conductor Material Copper Conductor Size #10 AWG Construction Fabricated Country of Origin US Currency USD Dimensions 24 in L Enclosure NEMA 4X EU RoHS Indicator N Gross Weight Per Pack 1.6500 lb Gross Weight per Pack Metric 0.75 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536308000 Height 9.70 in Height [Metric] 24.6380 cm Insulation Material Thermoplastic Length 3.20 in Length [Metric] 8.1280 cm Manufacturer Hubbell Material Thermoplastic Number Of Conductors 3 Returnable Y Standard UL LISTED Standards ARRA CompliantBuy American Act CompliantcULus ListedUL 943 Stock Status NONSTOCK Strands Multi Sub Brand Hard Wired 30A GFCI Type Hard Wired UNSPSC 26121536 UPC 11 78358500521 UPC 12 783585005218 Voltage Rating 240 VAC Width 5.70 in Width [Metric] 14.4780 cm Wire Into Circuit Manual Set- No Alarm Requires the GFCI to be manually reset for use by pressing the reset button after the loss of primary power Must be also manually reset after a ground fault condition Manual reset is ideal for applications where operator injury might occur if equipment were to restart after a power failure Offers a 4 to 6 mA trip level Green light illuminates when unit has power and no ground fault is present Red light begins blinking when a ground fault is detected and the output power is interrupted Black background with yellow lettering label color Gray with black cover unit 10 AWG, 24 in long wire lead Class A GFCI, 10000 cycles (6000 with load and 4000 without load) life Green light on power on, red blinking light plus optional audible alarm power off indicator Panel/surface mounting Manual set- no alarm Copper conductor Fabricated construction Thermoplastic insulation 3-outlet Multi strands
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Amperage Rating | 30 A |
| Application | Wire Into Circuit |
| ARRA Compliant | C |
| Brand | Hubbell Wiring Device-Kellems |
| Buy American Compliant | C |
| Catalog Number | GFHW23005 |
| Color | Black |
| Conductor Material | Copper |
| Conductor Size | #10 AWG |
| Construction | Fabricated |
| Country of Origin | US |
| Currency | USD |
| Dimensions | 24 in L |
| Enclosure | NEMA 4X |
| EU RoHS Indicator | N |
| Gross Weight Per Pack | 1.6500 lb |
| Gross Weight per Pack Metric | 0.75 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 8536308000 |
| Height | 9.70 in |
| Height [Metric] | 24.6380 cm |
| Insulation Material | Thermoplastic |
| Length | 3.20 in |
| Length [Metric] | 8.1280 cm |
| Manufacturer | Hubbell |
| Material | Thermoplastic |
| Number Of Conductors | 3 |
| Returnable | Y |
| Standard | UL LISTED |
| Standards | ARRA CompliantBuy American Act CompliantcULus ListedUL 943 |
| Stock Status | NONSTOCK |
| Strands | Multi |
| Sub Brand | Hard Wired 30A GFCI |
| Type | Hard Wired |
| UNSPSC | 26121536 |
| UPC 11 | 78358500521 |
| UPC 12 | 783585005218 |
| Voltage Rating | 240 VAC |
| Width | 5.70 in |
| Width [Metric] | 14.4780 cm |
| Wire Into Circuit |
| Manual Set- No Alarm |
| Requires the GFCI to be manually reset for use by pressing the reset button after the loss of primary power |
| Must be also manually reset after a ground fault condition |
| Manual reset is ideal for applications where operator injury might occur if equipment were to restart after a power failure |
| Offers a 4 to 6 mA trip level |
| Green light illuminates when unit has power and no ground fault is present |
| Red light begins blinking when a ground fault is detected and the output power is interrupted |
| Black background with yellow lettering label color |
| Gray with black cover unit |
| 10 AWG, 24 in long wire lead |
| Class A GFCI, 10000 cycles (6000 with load and 4000 without load) life |
| Green light on power on, red blinking light plus optional audible alarm power off indicator |
| Panel/surface mounting |
| Manual set- no alarm |
| Copper conductor |
| Fabricated construction |
| Thermoplastic insulation |
| 3-outlet |
| Multi strands |