HCI GFHW13015 HW GFCI, 30A 120V, MA
Custom_Product_Images_Illustration
Hubbell Wiring Device-Kellems
HCI GFHW13015 HW GFCI, 30A 120V, MA
SKU1065252
MFGR #GFHW13015
Your Cost: $622.29/ea
HW GFCI, 30A 120V, MAN, W/ENUN
HW GFCI, 30A 120V, MAN, W/ENUN
Application Wire Into Circuit ARRA Compliant C Buy American Compliant C Catalog Number GFHW13015 Color Black Conductor Material Copper Conductor Size #10 AWG Construction Fabricated Country of Origin US Currency USD EU RoHS Indicator N Gross Weight Per Pack 1.6000 lb Gross Weight per Pack Metric 0.73 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536308000 Height 6.80 in Height [Metric] 17.2720 cm Insulation Material Thermoplastic Length 3.20 in Length [Metric] 8.1280 cm Number Of Conductors 3 Returnable N Standard UL LISTED Standards cULus, UL 943, ARRA, Buy American Act Compliant Strands Multi Sub Brand Hard Wired 30A GFCI Temperature Rating -35 Degrees C to 66 Degrees C (-30 Degrees F to 150 Degrees F) °C Type Hard Wired, Alarm UNSPSC 26121536 UPC 11 78358500526 UPC 12 783585005263 Width 5.70 in Width [Metric] 14.4780 cm Stock Status NONSTOCK Brand Hubbell Wiring Device-Kellems Manufacturer Hubbell Amperage Rating 30 A Voltage Rating 120 VAC Wire Into Circuit Manual Set- Audible Alarm Requires the GFCI to be manually reset for use by pressing the reset button after the loss of primary power Must be also manually reset after a ground fault condition Manual reset is ideal for applications where operator injury might occur if equipment were to restart after a power failure Offers a 4 to 6 mA trip level The alarm alerts you if a ground fault has occurred and the GFCI has tripped The alarm may be disabled or wired into a switch so that the customer has the choice of use or non-use Green light illuminates when unit has power and no ground fault is present Red light begins blinking when a ground fault is detected and the output power is interrupted
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Application | Wire Into Circuit |
| ARRA Compliant | C |
| Buy American Compliant | C |
| Catalog Number | GFHW13015 |
| Color | Black |
| Conductor Material | Copper |
| Conductor Size | #10 AWG |
| Construction | Fabricated |
| Country of Origin | US |
| Currency | USD |
| EU RoHS Indicator | N |
| Gross Weight Per Pack | 1.6000 lb |
| Gross Weight per Pack Metric | 0.73 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 8536308000 |
| Height | 6.80 in |
| Height [Metric] | 17.2720 cm |
| Insulation Material | Thermoplastic |
| Length | 3.20 in |
| Length [Metric] | 8.1280 cm |
| Number Of Conductors | 3 |
| Returnable | N |
| Standard | UL LISTED |
| Standards | cULus, UL 943, ARRA, Buy American Act Compliant |
| Strands | Multi |
| Sub Brand | Hard Wired 30A GFCI |
| Temperature Rating | -35 Degrees C to 66 Degrees C (-30 Degrees F to 150 Degrees F) °C |
| Type | Hard Wired, Alarm |
| UNSPSC | 26121536 |
| UPC 11 | 78358500526 |
| UPC 12 | 783585005263 |
| Width | 5.70 in |
| Width [Metric] | 14.4780 cm |
| Stock Status | NONSTOCK |
| Brand | Hubbell Wiring Device-Kellems |
| Manufacturer | Hubbell |
| Amperage Rating | 30 A |
| Voltage Rating | 120 VAC |
| Wire Into Circuit |
| Manual Set- Audible Alarm |
| Requires the GFCI to be manually reset for use by pressing the reset button after the loss of primary power |
| Must be also manually reset after a ground fault condition |
| Manual reset is ideal for applications where operator injury might occur if equipment were to restart after a power failure |
| Offers a 4 to 6 mA trip level |
| The alarm alerts you if a ground fault has occurred and the GFCI has tripped |
| The alarm may be disabled or wired into a switch so that the customer has the choice of use or non-use |
| Green light illuminates when unit has power and no ground fault is present |
| Red light begins blinking when a ground fault is detected and the output power is interrupted |