or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Telemecanique Sensors
Telemecanique 9013GHG2J63 Pumptrol™ Electro-Mechanical Pressure Switch, 65 to 200 psi, 20 to 40 psi, 2NC DPST/DB
Custom_Product_Images_Illustration
Telemecanique Sensors
Telemecanique 9013GHG2J63 Pumptrol™ Electro-Mechanical Pressure Switch, 65 to 200 psi, 20 to 40 psi, 2NC DPST/DB
SKU98869
MFGR #9013GHG2J63
Your Cost: $127.47/ea
Telemecanique 9013GHG2J63 PRESSURE SWITCH 575VAC 5HP G +OPTIONS,-,0.25 inch NPSF internal conforming to UL 508,145...175 psi,20...40 psi,200 psi (40...170 psi),65...200 psi,300 PSIG,40 to 170 PSIG,DPST,General Purpose (Indoor),NEMA 1,Pressure Switch,Pumptrol,Screw Clamp,UL listed, CSA,air (-22...257 deg.F)-fresh water (-22...257 deg.F),control electrically driven water pumps and air compressors
Telemecanique 9013GHG2J63 PRESSURE SWITCH 575VAC 5HP G +OPTIONS,-,0.25 inch NPSF internal conforming to UL 508,145...175 psi,20...40 psi,200 psi (40...170 psi),65...200 psi,300 PSIG,40 to 170 PSIG,DPST,General Purpose (Indoor),NEMA 1,Pressure Switch,Pumptrol,Screw Clamp,UL listed, CSA,air (-22...257 deg.F)-fresh water (-22...257 deg.F),control electrically driven water pumps and air compressors
Alternate Catalog Number 9013GHG2J63 Application Control electrically driven water pumps and air compressors;Power circuit;Regulation between 2 thresholds ARRA Compliant N Buy American Compliant N Catalog Number 9013GHG2J63 Conduit Connection SCREW CLAMP Country of Origin MX Currency USD Decreasing Range 40 TO 170 PSIG Diaphragm Material Nitrile Dimensions 5.4 in H x 3.44 in W x 3.88 in D Enclosure NEMA 1 UL 50 Enclosure Type NEMA 1/IP20 Environmental Conditions GENERAL PURPOSE (INDOOR) EU RoHS Indicator Y Gross Volume Per Pack 223.30 Gross Volume per Pack Metric 3659.22 Gross Volume UOM CI Gross Volume UOM Metric cm3 Gross Weight Per Pack 1.9700 lb Gross Weight per Pack Metric 893.60 Gross Weight UOM Metric g Harmonization Tariff Schedule Code 9032200000 Height 9.9000 in Height [Metric] 9.9000 cm Housing Material Thermoplastic Increasing Range 65-200 PSI Item Group 21536 Length 14.5000 in Length [Metric] 14.5000 cm Material Composition Declaration https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=391853&lang=en-us Maximum Pressure 300 psi Operating Cycles 300000 Cycles Operating Temperature -33-257 A°F Process Connection 0.25 INCH NPSF INTERNAL UL 508 Process Fluid AIR -22-257 A°F)-FRESH WATER -22-257 A°F) Returnable Y Series 9013GH Standard IP20 IEC 60529,UL 508-NSF ANSI 372-CE,UL LISTED FILE E12158-CSA FILE LR25490 Sub Brand 9013GH System Pressure 200 PSI 40-170 PSI) Temperature Rating -33 to 257 °F Type Electro-Mechanical UNSPSC 39122210 UPC 11 78590155970 UPC 12 785901559702 Warranty Description Contractual Warranty:18 months Width 11.4000 in Width [Metric] 11.4000 cm Stock Status NONSTOCK Brand Telemecanique Sensors Manufacturer Telemecanique Sensors Connection Type Screw Clamp Contact Configuration 2NC DPST Contact Rating 5 hp at 575 VAC Differential 20 to 40 psi Pressure Rating 40 to 170 psig Control electrically driven water pumps and air compressors;Power circuit;Regulation between 2 thresholds - Contacts open on pressure rise The Class 9013 type G devices cover higher electrical ratings for direct control of motors in pump and compressor applications Diaphragm actuated 2 NC, snap action, DPST-DB, form YY contact -22 to 257 deg F air and fresh water controlled fluid 1/4 in NPSF internal fluid connection Regulation between 2 thresholds, adjustable differential scale 4-terminal block 10 AWG clamping capacity electrical connection Nitrile (Buna-N) diaphragm 300000 cycles mechanical durability, 100000 cycles at 10 cycles/min electrical durability Zinc plated steel or equivalent flange 2.2 kW at 115 VAC 3-phase, 0.75 kW at 230 VDC, 3.75 kW at 230 VAC 3-phase, 3.7 kW at 460 VAC 3-phase, 3.7 kW at 460 VAC, 1-phase, 3.7 kW at 575 VAC, 1-phase, 3.7 kW at 575 VAC 3-phase, 1.5 kW at 115 VAC, 1-phase, 2.2 kW at 230 VAC, 1-phase, 0.75 kW at 115 VDC power rating General purpose (indoor) environmental conditions Bracket mounting Standard action 3 knockouts for 1/2 in conduit UL508 cable entry Noryl thermoplastic resin 300 psig system pressure
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Alternate Catalog Number | 9013GHG2J63 |
Application | Control electrically driven water pumps and air compressors;Power circuit;Regulation between 2 thresholds |
ARRA Compliant | N |
Buy American Compliant | N |
Catalog Number | 9013GHG2J63 |
Conduit Connection | SCREW CLAMP |
Country of Origin | MX |
Currency | USD |
Decreasing Range | 40 TO 170 PSIG |
Diaphragm Material | Nitrile |
Dimensions | 5.4 in H x 3.44 in W x 3.88 in D |
Enclosure | NEMA 1 UL 50 |
Enclosure Type | NEMA 1/IP20 |
Environmental Conditions | GENERAL PURPOSE (INDOOR) |
EU RoHS Indicator | Y |
Gross Volume Per Pack | 223.30 |
Gross Volume per Pack Metric | 3659.22 |
Gross Volume UOM | CI |
Gross Volume UOM Metric | cm3 |
Gross Weight Per Pack | 1.9700 lb |
Gross Weight per Pack Metric | 893.60 |
Gross Weight UOM Metric | g |
Harmonization Tariff Schedule Code | 9032200000 |
Height | 9.9000 in |
Height [Metric] | 9.9000 cm |
Housing Material | Thermoplastic |
Increasing Range | 65-200 PSI |
Item Group | 21536 |
Length | 14.5000 in |
Length [Metric] | 14.5000 cm |
Material Composition Declaration | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=391853&lang=en-us |
Maximum Pressure | 300 psi |
Operating Cycles | 300000 Cycles |
Operating Temperature | -33-257 A°F |
Process Connection | 0.25 INCH NPSF INTERNAL UL 508 |
Process Fluid | AIR -22-257 A°F)-FRESH WATER -22-257 A°F) |
Returnable | Y |
Series | 9013GH |
Standard | IP20 IEC 60529,UL 508-NSF ANSI 372-CE,UL LISTED FILE E12158-CSA FILE LR25490 |
Sub Brand | 9013GH |
System Pressure | 200 PSI 40-170 PSI) |
Temperature Rating | -33 to 257 °F |
Type | Electro-Mechanical |
UNSPSC | 39122210 |
UPC 11 | 78590155970 |
UPC 12 | 785901559702 |
Warranty Description | Contractual Warranty:18 months |
Width | 11.4000 in |
Width [Metric] | 11.4000 cm |
Stock Status | NONSTOCK |
Brand | Telemecanique Sensors |
Manufacturer | Telemecanique Sensors |
Connection Type | Screw Clamp |
Contact Configuration | 2NC DPST |
Contact Rating | 5 hp at 575 VAC |
Differential | 20 to 40 psi |
Pressure Rating | 40 to 170 psig |
Control electrically driven water pumps and air compressors;Power circuit;Regulation between 2 thresholds |
- |
Contacts open on pressure rise |
The Class 9013 type G devices cover higher electrical ratings for direct control of motors in pump and compressor applications |
Diaphragm actuated |
2 NC, snap action, DPST-DB, form YY contact |
-22 to 257 deg F air and fresh water controlled fluid |
1/4 in NPSF internal fluid connection |
Regulation between 2 thresholds, adjustable differential scale |
4-terminal block |
10 AWG clamping capacity electrical connection |
Nitrile (Buna-N) diaphragm |
300000 cycles mechanical durability, 100000 cycles at 10 cycles/min electrical durability |
Zinc plated steel or equivalent flange |
2.2 kW at 115 VAC 3-phase, 0.75 kW at 230 VDC, 3.75 kW at 230 VAC 3-phase, 3.7 kW at 460 VAC 3-phase, 3.7 kW at 460 VAC, 1-phase, 3.7 kW at 575 VAC, 1-phase, 3.7 kW at 575 VAC 3-phase, 1.5 kW at 115 VAC, 1-phase, 2.2 kW at 230 VAC, 1-phase, 0.75 kW at 115 VDC power rating |
General purpose (indoor) environmental conditions |
Bracket mounting |
Standard action |
3 knockouts for 1/2 in conduit UL508 cable entry |
Noryl thermoplastic resin |
300 psig system pressure |