or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Telemecanique 9013GHG1S8J54 Pumptrol™ Electro-Mechanical Pressure Switch, 65 to 200 psi, 20 to 40 psi, 2NC DPST/DB
Custom_Product_Images_Illustration
Telemecanique 9013GHG1S8J54 Pumptrol™ Electro-Mechanical Pressure Switch, 65 to 200 psi, 20 to 40 psi, 2NC DPST/DB
SKU98468
MFGR #9013GHG1S8J54
Your Cost: $137.81/ea
Telemecanique 9013GHG1S8J54 PRESSURE SWITCH 575VAC 5HP G +OPTIONS,0.13 Inch NPSF,20...40 psi,65...200 psi,300 PSIG,40...170 psi,DPST,General Purpose (Indoor),NEMA 1,Pressure Switch,Pumptrol,Screw Clamp,UL listed, CSA,control electrically driven water pumps and air compressors
Telemecanique 9013GHG1S8J54 PRESSURE SWITCH 575VAC 5HP G +OPTIONS,0.13 Inch NPSF,20...40 psi,65...200 psi,300 PSIG,40...170 psi,DPST,General Purpose (Indoor),NEMA 1,Pressure Switch,Pumptrol,Screw Clamp,UL listed, CSA,control electrically driven water pumps and air compressors
Application Control electrically driven water pumps and air compressors ARRA Compliant C Buy American Compliant C Catalog Number 9013GHG1S8J54 Conduit Connection SCREW CLAMP Connection Material Zinc Plated Steel Country of Origin MX Currency USD Decreasing Range 40-170 PSI Diaphragm Material Nitrile Dimensions 5.72 in H x 3.44 in W x 3.68 in D Enclosure NEMA 1,STANDARD ENVIRONMENT ENCLOSURE INDOOR Enclosure Type NEMA 1/IP20 Environmental Conditions GENERAL PURPOSE (INDOOR) EU RoHS Indicator Y Gross Volume Per Pack 103.54 Gross Volume per Pack Metric 1696.80 Gross Volume UOM CI Gross Volume UOM Metric cm3 Gross Weight Per Pack 1860.0400 lb Gross Weight per Pack Metric 843.70 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 9032200000 Height 9.9000 in Height [Metric] 9.9060 cm Housing Material Thermoplastic Increasing Range 110-125 PSI,65-200 PSI Item Group 21536 Length 14.2000 in Length [Metric] 14.9860 cm Maximum Pressure 300 psi Mounting By brackets Operating Cycles 300000 Cycles Process Connection 0.125 INCH NPSF INTERNAL Returnable Y Standard CSA FILE LR25490-UL LISTED FILE E12158 CCN NKPZ Sub Brand G System Pressure 300 PSIG Temperature Rating -33 to 257 °F Type Electro-Mechanical UNSPSC 39122210 UPC 11 78590146142 UPC 12 785901461425 Width 11.2000 in Width [Metric] 11.4300 cm Stock Status NONSTOCK Brand Telemecanique Sensors Manufacturer Telemecanique Sensors Connection Type Screw Clamp Contact Configuration 2NC DPST/DB Differential 20 to 40 psi Pressure Rating 40 to 170 psi CONTROL ELECTRICALLY DRIVEN WATER PUMPS AND AIR COMPRESSORS DPST Contacts open on pressure rise The Class 9013 type G devices cover higher electrical ratings for direct control of motors in pump and compressor applications Diaphragm actuated 2 NC, snap action, DPST-DB, form YY contact -22 to 257 deg F air and fresh water controlled fluid 0.13 in NPSF internal fluid connection Regulation between 2 thresholds, adjustable differential scale 4-terminal block 10 AWG clamping capacity Nitrile (Buna-N) diaphragm 300000 cycles mechanical durability, 100000 cycles at 10 cycles/min electrical durability Zinc plated steel or equivalent flange 5 hp 460/575 VAC 1-phase, 3 hp 230 VAC 1-phase, 2 hp 115 VAC 1-phase, 3 hp 115 VAC 3-phase, 5 hp 460/575 VAC 3-phase, 5 hp 230 VAC 3-phase power rated General purpose (indoor) environmental conditions Bracket mounting Standard action 3 knock-outs for 1/2 in conduit UL508 cable entry Noryl thermoplastic resin 300 psig system pressure
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Application | Control electrically driven water pumps and air compressors |
ARRA Compliant | C |
Buy American Compliant | C |
Catalog Number | 9013GHG1S8J54 |
Conduit Connection | SCREW CLAMP |
Connection Material | Zinc Plated Steel |
Country of Origin | MX |
Currency | USD |
Decreasing Range | 40-170 PSI |
Diaphragm Material | Nitrile |
Dimensions | 5.72 in H x 3.44 in W x 3.68 in D |
Enclosure | NEMA 1,STANDARD ENVIRONMENT ENCLOSURE INDOOR |
Enclosure Type | NEMA 1/IP20 |
Environmental Conditions | GENERAL PURPOSE (INDOOR) |
EU RoHS Indicator | Y |
Gross Volume Per Pack | 103.54 |
Gross Volume per Pack Metric | 1696.80 |
Gross Volume UOM | CI |
Gross Volume UOM Metric | cm3 |
Gross Weight Per Pack | 1860.0400 lb |
Gross Weight per Pack Metric | 843.70 |
Gross Weight UOM Metric | kg |
Harmonization Tariff Schedule Code | 9032200000 |
Height | 9.9000 in |
Height [Metric] | 9.9060 cm |
Housing Material | Thermoplastic |
Increasing Range | 110-125 PSI,65-200 PSI |
Item Group | 21536 |
Length | 14.2000 in |
Length [Metric] | 14.9860 cm |
Maximum Pressure | 300 psi |
Mounting | By brackets |
Operating Cycles | 300000 Cycles |
Process Connection | 0.125 INCH NPSF INTERNAL |
Returnable | Y |
Standard | CSA FILE LR25490-UL LISTED FILE E12158 CCN NKPZ |
Sub Brand | G |
System Pressure | 300 PSIG |
Temperature Rating | -33 to 257 °F |
Type | Electro-Mechanical |
UNSPSC | 39122210 |
UPC 11 | 78590146142 |
UPC 12 | 785901461425 |
Width | 11.2000 in |
Width [Metric] | 11.4300 cm |
Stock Status | NONSTOCK |
Brand | Telemecanique Sensors |
Manufacturer | Telemecanique Sensors |
Connection Type | Screw Clamp |
Contact Configuration | 2NC DPST/DB |
Differential | 20 to 40 psi |
Pressure Rating | 40 to 170 psi |
CONTROL ELECTRICALLY DRIVEN WATER PUMPS AND AIR COMPRESSORS |
DPST |
Contacts open on pressure rise |
The Class 9013 type G devices cover higher electrical ratings for direct control of motors in pump and compressor applications |
Diaphragm actuated |
2 NC, snap action, DPST-DB, form YY contact |
-22 to 257 deg F air and fresh water controlled fluid |
0.13 in NPSF internal fluid connection |
Regulation between 2 thresholds, adjustable differential scale |
4-terminal block |
10 AWG clamping capacity |
Nitrile (Buna-N) diaphragm |
300000 cycles mechanical durability, 100000 cycles at 10 cycles/min electrical durability |
Zinc plated steel or equivalent flange |
5 hp 460/575 VAC 1-phase, 3 hp 230 VAC 1-phase, 2 hp 115 VAC 1-phase, 3 hp 115 VAC 3-phase, 5 hp 460/575 VAC 3-phase, 5 hp 230 VAC 3-phase power rated |
General purpose (indoor) environmental conditions |
Bracket mounting |
Standard action |
3 knock-outs for 1/2 in conduit UL508 cable entry |
Noryl thermoplastic resin |
300 psig system pressure |