SolaHD MCR Hardwired Power Line Conditioner, 600 VAC Input, 120/208/240 VAC Output, 1 Phase
Custom_Product_Images_Illustration
SolaHD MCR Hardwired Power Line Conditioner, 600 VAC Input, 120/208/240 VAC Output, 1 Phase
SKU355051
MFGR #63322308
Your Cost: $5,109.57/ea
The MCR Hardwired Series provides excellent noise filtering and surge protection to safeguard connected equipment from damage, degradation or misoperation. Combined with the excellent voltage regulation inherent to SolaHD's ferroresonant design, the MCR can increase the actual Mean Time Between Failure (MTBF) of protected equipment. The MCR is a perfect choice where dirty power, caused by impulses, swell, sags, brownouts and waveform distortion can lead to costly downtime because of damaged equipment.
The MCR Hardwired Series provides excellent noise filtering and surge protection to safeguard connected equipment from damage, degradation or misoperation. Combined with the excellent voltage regulation inherent to SolaHD's ferroresonant design, the MCR can increase the actual Mean Time Between Failure (MTBF) of protected equipment. The MCR is a perfect choice where dirty power, caused by impulses, swell, sags, brownouts and waveform distortion can lead to costly downtime because of damaged equipment.
- Application - Industrial Automation and Control Equipment Power PLCs, Machine Tools, Robotics, Semiconductor Fabrication Equipment - ARRA Compliant - Y - Buy American Compliant - Y - Catalog Number - 63322308 - Country of Origin - US - Currency - USD - EU RoHS Indicator - Y - Frequency Rating - 60 Hz - Gross Weight Per Pack - 138.0000 lb - Gross Weight per Pack Metric - 62.60 - Gross Weight UOM Metric - kg - Height - 16.00 in - Height [Metric] - 40.6400 cm - Input - 600 VAC - Length - 24.00 in - Length [Metric] - 60.9600 cm - Mounting - Bracket - Noise Level - 35 to 65 dBA - Output Power - 120/208/240 VAC - Standard - cULus Listed: (500VA-3kVA Units) UL 1012, CSA C22.2 No. 66; CSA Certified (5kVA-15kVA Units) CSA C22.2 No. 66, RoHS Compliant - Standards - RoHS Compliant, cULus Listed, UL 1012, CSA C22.2 No. 107.1, CSA C22.2 No. 66 - Style - 1 - Type - MCR Hardwired Series Power Line Conditioning with Voltage Regulation - UNSPSC - 43222901 - UPC 11 - 78347213615 - UPC 12 - 783472136155 - Width - 14.00 in - Width [Metric] - 35.5600 cm - Stock Status - NONSTOCK - Brand - SolaHD™ - Manufacturer - Emerson 
- Industrial Automation and Control Equipment Power PLCs, Machine Tools, Robotics, Semiconductor Fabrication Equipment 
- +/- 3% output voltage regulation, Surge protection tested to ANSI/IEEE C62.41. Class A & B waveform, Harmonic filtering, Galvanic isolation, Noise attenuation 120 dB common mode/60 dB transverse mode - +/-3% output voltage regulation - Surge protection tested to ANSI/IEEE C6241 Class A and B waveform of <10 V let through typical - Acts as a step-up or step-down transformer - Harmonic filtering, hardwired - Galvanic isolation provides exceptional circuit protection - 25 year typical MTBF - No maintenance required - Noise attenuation of 120 dB common mode, 60 dB transverse mode - 35 - 65 dBA Full audible resistive noise 
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Application | Industrial Automation and Control Equipment Power PLCs, Machine Tools, Robotics, Semiconductor Fabrication Equipment | 
| ARRA Compliant | Y | 
| Buy American Compliant | Y | 
| Catalog Number | 63322308 | 
| Country of Origin | US | 
| Currency | USD | 
| EU RoHS Indicator | Y | 
| Frequency Rating | 60 Hz | 
| Gross Weight Per Pack | 138.0000 lb | 
| Gross Weight per Pack Metric | 62.60 | 
| Gross Weight UOM Metric | kg | 
| Height | 16.00 in | 
| Height [Metric] | 40.6400 cm | 
| Input | 600 VAC | 
| Length | 24.00 in | 
| Length [Metric] | 60.9600 cm | 
| Mounting | Bracket | 
| Noise Level | 35 to 65 dBA | 
| Output Power | 120/208/240 VAC | 
| Standard | cULus Listed: (500VA-3kVA Units) UL 1012, CSA C22.2 No. 66; CSA Certified (5kVA-15kVA Units) CSA C22.2 No. 66, RoHS Compliant | 
| Standards | RoHS Compliant, cULus Listed, UL 1012, CSA C22.2 No. 107.1, CSA C22.2 No. 66 | 
| Style | 1 | 
| Type | MCR Hardwired Series Power Line Conditioning with Voltage Regulation | 
| UNSPSC | 43222901 | 
| UPC 11 | 78347213615 | 
| UPC 12 | 783472136155 | 
| Width | 14.00 in | 
| Width [Metric] | 35.5600 cm | 
| Stock Status | NONSTOCK | 
| Brand | SolaHD™ | 
| Manufacturer | Emerson | 
| Industrial Automation and Control Equipment Power PLCs, Machine Tools, Robotics, Semiconductor Fabrication Equipment | 
| +/- 3% output voltage regulation, Surge protection tested to ANSI/IEEE C62.41. Class A & B waveform, Harmonic filtering, Galvanic isolation, Noise attenuation 120 dB common mode/60 dB transverse mode | 
| +/-3% output voltage regulation | 
| Surge protection tested to ANSI/IEEE C6241 Class A and B waveform of <10 V let through typical | 
| Acts as a step-up or step-down transformer | 
| Harmonic filtering, hardwired | 
| Galvanic isolation provides exceptional circuit protection | 
| 25 year typical MTBF | 
| No maintenance required | 
| Noise attenuation of 120 dB common mode, 60 dB transverse mode | 
| 35 - 65 dBA Full audible resistive noise |