Siemens 3RV2011-1GA15 Type 3RV2 Motor Protection Circuit Breaker, 690 VAC, 6.3 A, 4 kA Interrupt, 3 Poles
Custom_Product_Images_Illustration
Siemens 3RV2011-1GA15 Type 3RV2 Motor Protection Circuit Breaker, 690 VAC, 6.3 A, 4 kA Interrupt, 3 Poles
SKU749868
MFGR #3RV20111GA15
Your Cost: $174.00/ea
List: Siemens 3RV20111GA15 MSP S00 4.5-6.3A AUX 1NO 1NC SCREW
Siemens 3RV20111GA15 MSP S00 4.5-6.3A AUX 1NO 1NC SCREW
Alternate Catalog Number 3RV2011-1GA15 Application Used as Manual Motor Controller and in Group Installation ARRA Compliant C Auxiliary Contact Rating 1NO-1NC Buy American Compliant C Catalog Number 3RV20111GA15 Connection screw-type terminals Connection Type Screw Country of Origin DE Currency USD Dimensions 97 mm H x 45 mm W x 97 mm D Enclosure Type IP20 Environmental Conditions 80 -50 C EU RoHS Indicator C Frame S00 Frequency Rating 50/60 Hz Gross Volume Per Pack 31.19 Gross Volume UOM in Gross Weight Per Pack 0.8000 lb Gross Weight per Pack Metric 0.36 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536304000 Height 4.0200 in Height [Metric] 10.2108 cm Length 4.0200 in Length [Metric] 10.2108 cm Mounting Type DIN Rail/Snap-On/Threaded Number Of Poles 3 Operating Temperature 60 to -20 °C Phase 3 Power Rating 4 kW Returnable Y Standard CE / UL / CSA / CCC Standards CCC CertifiedCSA CertifiedUL ListedEAC ApprovedEX ATEXIECEx CertifiedCE CertifiedVDE ApprovedRoHS CompliantABS ApprovedBureau Veritas CertifiedLloyd's RegisteredPRS CertifiedRINA CertifiedRMRS ApprovedDNV-GL ApprovedEN 60715 Sub Brand Sirius Temperature Rating -20 to 60 °C Trip Range 4.5 to 6.3 A, 82 A Type Type 3RV2 UNSPSC 39121601 UPC 11 66264392403 UPC 12 662643924039 Width 1.9300 in Width [Metric] 4.9022 cm Wire Size 18 to 14 AWG, 12 AWG Stock Status NONSTOCK Brand Siemens Manufacturer Siemens Amperage Rating 6.3 A Interrupt Rating 6 kA Trip Type Thermomagnetic Voltage Rating 690 VAC Used as Manual Motor Controller and in Group Installation MSP?s are UL approved as Self Protected Combination Motor Controllers Minimization of energy losses through optimization of the bimetal trip units Reduction of inherent power loss Less heating of the control cabinet Smaller control cabinet air conditioners can be used 3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks) 1500 W at 230 VAC, 2200 W at 400 VAC, 3000 W at 500 VAC, 4000 W at 690 VAC 100 kA at 240 VAC, 100 kA at 400 VAC, 100 kA at 500 VAC, 6 kA at 690 VAC 4.5 to 6.3 A thermal overload release, 82 A instantaneous overcurrent release
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Alternate Catalog Number | 3RV2011-1GA15 |
Application | Used as Manual Motor Controller and in Group Installation |
ARRA Compliant | C |
Auxiliary Contact Rating | 1NO-1NC |
Buy American Compliant | C |
Catalog Number | 3RV20111GA15 |
Connection | screw-type terminals |
Connection Type | Screw |
Country of Origin | DE |
Currency | USD |
Dimensions | 97 mm H x 45 mm W x 97 mm D |
Enclosure Type | IP20 |
Environmental Conditions | 80 -50 C |
EU RoHS Indicator | C |
Frame | S00 |
Frequency Rating | 50/60 Hz |
Gross Volume Per Pack | 31.19 |
Gross Volume UOM | in |
Gross Weight Per Pack | 0.8000 lb |
Gross Weight per Pack Metric | 0.36 |
Gross Weight UOM Metric | kg |
Harmonization Tariff Schedule Code | 8536304000 |
Height | 4.0200 in |
Height [Metric] | 10.2108 cm |
Length | 4.0200 in |
Length [Metric] | 10.2108 cm |
Mounting Type | DIN Rail/Snap-On/Threaded |
Number Of Poles | 3 |
Operating Temperature | 60 to -20 °C |
Phase | 3 |
Power Rating | 4 kW |
Returnable | Y |
Standard | CE / UL / CSA / CCC |
Standards | CCC CertifiedCSA CertifiedUL ListedEAC ApprovedEX ATEXIECEx CertifiedCE CertifiedVDE ApprovedRoHS CompliantABS ApprovedBureau Veritas CertifiedLloyd's RegisteredPRS CertifiedRINA CertifiedRMRS ApprovedDNV-GL ApprovedEN 60715 |
Sub Brand | Sirius |
Temperature Rating | -20 to 60 °C |
Trip Range | 4.5 to 6.3 A, 82 A |
Type | Type 3RV2 |
UNSPSC | 39121601 |
UPC 11 | 66264392403 |
UPC 12 | 662643924039 |
Width | 1.9300 in |
Width [Metric] | 4.9022 cm |
Wire Size | 18 to 14 AWG, 12 AWG |
Stock Status | NONSTOCK |
Brand | Siemens |
Manufacturer | Siemens |
Amperage Rating | 6.3 A |
Interrupt Rating | 6 kA |
Trip Type | Thermomagnetic |
Voltage Rating | 690 VAC |
Used as Manual Motor Controller and in Group Installation |
MSP?s are UL approved as Self Protected Combination Motor Controllers |
Minimization of energy losses through optimization of the bimetal trip units |
Reduction of inherent power loss |
Less heating of the control cabinet |
Smaller control cabinet air conditioners can be used |
3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks) |
1500 W at 230 VAC, 2200 W at 400 VAC, 3000 W at 500 VAC, 4000 W at 690 VAC |
100 kA at 240 VAC, 100 kA at 400 VAC, 100 kA at 500 VAC, 6 kA at 690 VAC |
4.5 to 6.3 A thermal overload release, 82 A instantaneous overcurrent release |