Schneider Electric TeSys™ LA1KN04 Auxiliary Contact Block, 690 VAC, 0.41 A, 4NC Contacts
Custom_Product_Images_Illustration
Schneider Electric TeSys™ LA1KN04 Auxiliary Contact Block, 690 VAC, 0.41 A, 4NC Contacts
SKU35124
MFGR #LA1KN04
Your Cost: $17.13/ea
Schneider Electric LA1KN04 CONTACTOR+RELAY AUX CONTACT 575VAC 10A,10 A at <= 50 deg.C,4 NC,CA3K-CA2K,LA1,Clip-on (Front),LA1,auxiliary contact block,Screw Clamp,TeSys,TeSys K-TeSys K control relay,UL Listed File Number E164353 CCN NKCR - CSA Certified File Number LR43364 Class 321102 - CE Marked
Schneider Electric LA1KN04 CONTACTOR+RELAY AUX CONTACT 575VAC 10A,10 A at <= 50 deg.C,4 NC,CA3K-CA2K,LA1,Clip-on (Front),LA1,auxiliary contact block,Screw Clamp,TeSys,TeSys K-TeSys K control relay,UL Listed File Number E164353 CCN NKCR - CSA Certified File Number LR43364 Class 321102 - CE Marked
Alternate Catalog Number LA1KN04 Amperage Rating 10 A Application TeSys K LC1K;TeSys K CA2K;TeSys K CA3K ARRA Compliant N Brand Square D™ Buy American Compliant N Catalog Number LA1KN04 Contact Configuration 4 NC,INSTANTANEOUS Contact Rating 10 A 50 A°C Country of Origin ID Currency USD Dimensions 35 mm D Environmental Conditions IP2X, 2000 m Operating Altitude EU RoHS Indicator Y Frequency Rating 400 Hz Gross Volume Per Pack 2.91 Gross Volume per Pack Metric 47.69 Gross Volume UOM CI Gross Volume UOM Metric cm3 Gross Weight Per Pack 0.0900 lb Gross Weight per Pack Metric 40.00 Gross Weight UOM Metric g Harmonization Tariff Schedule Code 8536509040 Height 4.0000 in Height [Metric] 4.0000 cm Item Group 22341 Length 3.8000 in Length [Metric] 4.0000 cm Manufacturer Schneider Electric Material Composition Declaration https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=608438&lang=en-us Mounting CLIP-ON (FRONT) Mounting Type Clip-On/Front Operating Temperature -25 to 50 °C Returnable Y Series LA1 Size 35 MM in Standard CSA-UL,IP2X VDE 0106,VDE 0660-IEC 60947-NF C 63-110-BS 5424 Standards ARRA CompliantBuy American Act CompliantRoHS CompliantCE MarkedCSA File No. LR43364 Class 3211 02BS 5424IEC 60947NF C 63-110UL File No. E164353VDE 0660 CCN NKCR Certifiedeccn: EAR99 Stock Status NONSTOCK Sub Brand TESYS Suitable For Use With CA2K, CA3K, TeSys™ K Contactor Type Instantaneous UNSPSC 39121522 UPC 11 78590189867 UPC 12 785901898672 Voltage Rating 690 VAC Warranty Description Contractual Warranty:18 months Width 4.0000 in Width [Metric] 3.8000 cm TeSys K LC1K;TeSys K CA2K;TeSys K CA3K NORMAL ENVIRONMENT Screw clamp terminal electrical connection 17 V minimum switching voltage 5 mA minimum switching current 600/690/750 VAC rated insulation voltage 10 A at <= 50 deg C conventional free air thermal current 110 A amperage at <= 690 VAC conforming to IEC 60947 Irms rated making capacity 80 A 1 sec, 60 A 500 ms, 110 A 100 ms permissible short-time rating 10 A gG <= 690 V IEC 60947, 10 A gG <= 690 V VDE 0660 associated fuse rating 0.5 mm non-overlap distance > 10 MOhm for control circuit insulation resistance 1.3 N-m tightening torque on screw clamp terminals with screwdriver Philips No 2 IP2X conforming to VDE 0106 TC conforming to IEC 60068 protective treatment 2000 m operating altitude without derating in temperature Instantaneous auxiliary contacts operation
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Alternate Catalog Number | LA1KN04 |
Amperage Rating | 10 A |
Application | TeSys K LC1K;TeSys K CA2K;TeSys K CA3K |
ARRA Compliant | N |
Brand | Square D™ |
Buy American Compliant | N |
Catalog Number | LA1KN04 |
Contact Configuration | 4 NC,INSTANTANEOUS |
Contact Rating | 10 A 50 A°C |
Country of Origin | ID |
Currency | USD |
Dimensions | 35 mm D |
Environmental Conditions | IP2X, 2000 m Operating Altitude |
EU RoHS Indicator | Y |
Frequency Rating | 400 Hz |
Gross Volume Per Pack | 2.91 |
Gross Volume per Pack Metric | 47.69 |
Gross Volume UOM | CI |
Gross Volume UOM Metric | cm3 |
Gross Weight Per Pack | 0.0900 lb |
Gross Weight per Pack Metric | 40.00 |
Gross Weight UOM Metric | g |
Harmonization Tariff Schedule Code | 8536509040 |
Height | 4.0000 in |
Height [Metric] | 4.0000 cm |
Item Group | 22341 |
Length | 3.8000 in |
Length [Metric] | 4.0000 cm |
Manufacturer | Schneider Electric |
Material Composition Declaration | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=608438&lang=en-us |
Mounting | CLIP-ON (FRONT) |
Mounting Type | Clip-On/Front |
Operating Temperature | -25 to 50 °C |
Returnable | Y |
Series | LA1 |
Size | 35 MM in |
Standard | CSA-UL,IP2X VDE 0106,VDE 0660-IEC 60947-NF C 63-110-BS 5424 |
Standards | ARRA CompliantBuy American Act CompliantRoHS CompliantCE MarkedCSA File No. LR43364 Class 3211 02BS 5424IEC 60947NF C 63-110UL File No. E164353VDE 0660 CCN NKCR Certifiedeccn: EAR99 |
Stock Status | NONSTOCK |
Sub Brand | TESYS |
Suitable For Use With | CA2K, CA3K, TeSys™ K Contactor |
Type | Instantaneous |
UNSPSC | 39121522 |
UPC 11 | 78590189867 |
UPC 12 | 785901898672 |
Voltage Rating | 690 VAC |
Warranty Description | Contractual Warranty:18 months |
Width | 4.0000 in |
Width [Metric] | 3.8000 cm |
TeSys K LC1K;TeSys K CA2K;TeSys K CA3K |
NORMAL ENVIRONMENT |
Screw clamp terminal electrical connection |
17 V minimum switching voltage |
5 mA minimum switching current |
600/690/750 VAC rated insulation voltage |
10 A at <= 50 deg C conventional free air thermal current |
110 A amperage at <= 690 VAC conforming to IEC 60947 Irms rated making capacity |
80 A 1 sec, 60 A 500 ms, 110 A 100 ms permissible short-time rating |
10 A gG <= 690 V IEC 60947, 10 A gG <= 690 V VDE 0660 associated fuse rating |
0.5 mm non-overlap distance |
> 10 MOhm for control circuit insulation resistance |
1.3 N-m tightening torque on screw clamp terminals with screwdriver Philips No 2 |
IP2X conforming to VDE 0106 |
TC conforming to IEC 60068 protective treatment |
2000 m operating altitude without derating in temperature |
Instantaneous auxiliary contacts operation |