Schneider Electric Preventa™ XPSAV Electronic Internal Safety Relay, 10 mA, 6NO Contact Form, 24 VDC Coil
Safety Relays
291441
MFG #: XPSAV11113
Schneider Electric
660.75000
/ ea
Schneider Electric XPSAV11113 SAFETY RELAY 300V 2.5AMP PREVENTA,24 V DC,35 mm symmetrical DIN rail,CSA, TV, UL, EN 1088/ISO 14119, EN 60204-1, EN/IEC 60947-5-1, EN/ISO 13850,IP20 conforming to EN/IEC 60529(terminals), IP40 conforming to EN/IEC 60529(enclosure),Preventa,Preventa Safety automation,for emergency stop and switch monitoring,Preventa safety module,captive screw clamp terminals,relay instantaneous opening 3 NO, relay time delay opening 3 NO
- Catalog URL - Square_D_XPSAV11113_Catalog.pdf(Catalog URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=XPSAV11113_2D Front View.dwg(Computer~Aided [CAD|BIM] Model URL)
- Service Manual URL - files?p_enDocType=End of life manual&p_File_Name=ENVEOLI111222EN_V0.pdf(Service Manual URL)
- Spec Sheet URL - XPSAV11113(Spec Sheet URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Line Drawing URL(Line Drawing URL)
- Tech Drawing URL - sales?sn=XPSAV11113(Tech Drawing URL)
- Features
IP20 TERMINALS)EN/IEC 60529-IP40 ENCLOSURE)EN/IEC 60529 |
Emergency stop button with 1NC contacts, automatic start or unmonitored start |
Monitoring of a movable guard associated with 2 switches automatic start |
Emergency stop monitoring 1-channel wiring |
Emergency stop button with 2NC contacts, monitored start |
Emergency stop monitoring 2-channel wiring |
They provide protective for both the machine operator and the machine by immediately stopping the dangerous movement on receipt of a stop instruction from the operator or on detection of a fault in the safety circuit itself |
To aid diagnostics, the modules have LED's which provide information on the monitoring circuit status |
Module XPSAV also incorporates 3 solid state signaling outputs for signaling to the process PLC |
20 A for relay output conventional-free air thermal current |
10 mA relay output minimum current |
17 VAC for relay output minimum output voltage |
<= 30 ms response time on input open |
300 VAC rated insulation voltage |
4 kVAC rated impulse withstand voltage |
100 Ohm line resistance |
C300 breaking capacity |
C300 breaking capacity |
<= 5 W DC power rating |
C300 breaking capacity |