or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Square D™
Schneider Electric LHL36200 Adjustable High Interrupt Molded Case Circuit Breaker, 600 VAC/250 VDC, 200 A, 3 Poles
Custom_Product_Images_Illustration
Square D™
Schneider Electric LHL36200 Adjustable High Interrupt Molded Case Circuit Breaker, 600 VAC/250 VDC, 200 A, 3 Poles
SKU96422
MFGR #LHL36200
Your Cost: $6,588.56/ea
List: Schneider Electric LHL36200 MOLDED CASE CIRCUIT BREAKER 600V 200A,1000...2000 A,200 A,200 A,25 kA at 600 V AC-50 kA at 125 V DC-50 kA at 250 V DC-65 kA at 240 V AC-35 kA at 480 V AC,250 V DC-600 V AC,250 V DC-600 V AC,circuit breaker,unit mount
Schneider Electric LHL36200 MOLDED CASE CIRCUIT BREAKER 600V 200A,1000...2000 A,200 A,200 A,25 kA at 600 V AC-50 kA at 125 V DC-50 kA at 250 V DC-65 kA at 240 V AC-35 kA at 480 V AC,250 V DC-600 V AC,250 V DC-600 V AC,circuit breaker,unit mount
Alternate Catalog Number LHL36200 ARRA Compliant N Buy American Compliant N Catalog Number LHL36200 Connection AWG 1...600 KCMIL ALUMINIUM/COPPER)1 -AWG 1...250 KCMIL ALUMINIUM/COPPER)2,LUGS LOAD-LUGS LINE Connection Type Line/Load Lug Country of Origin US Currency USD Dimensions 11 in H x 6 in W x 5.84 in D Enclosure Type NEMA 1/3R/12/4/4X/5 EU RoHS Indicator Y Frame LH Series Frequency Rating 50/60 Hz Gross Weight Per Pack 16.1800 lb Gross Weight per Pack Metric 7.34 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536200020 Height 21.4330 in Height [Metric] 21.4330 cm Item Group 00935 Length 43.4980 in Length [Metric] 43.4980 cm Material Composition Declaration https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=430225&lang=en-us Mounting Type Unit Number Of Poles 3 Phase 3 pH Returnable Y Standard UL LISTED-IEC-CSA Temperature Rating 104 °F Trip Range 1000 to 2000 A Type Adjustable High Interrupt UNSPSC 39121601 UPC 11 78590108212 UPC 12 785901082125 Warranty Description Contractual Warranty:18 months Width 28.2580 in Width [Metric] 28.2580 cm Wire Size (1) 1 AWG to 600 kcmil/(2)1 AWG to 250 kcmil Al/Cu Stock Status NONSTOCK Brand Square D™ Manufacturer Schneider Electric Amperage Rating 200 A Interrupt Rating 65 kA at 240 VAC/35 kA at 480 VAC/25 kA at 600 VAC/50 kA at 125/250 VDC Trip Type Thermal Magnetic Voltage Rating 600 VAC/250 VDC UNIT MOUNT Common accessories and auxiliaries with other PowerPact™ frames Common accessories across the range of PowerPact™ molded case circuit breakers allow users to make late specification changes A wide range of field installable accessories allows customers to reduce inventory without sacrificing flexibility Broad offering of operating mechanisms and ratings specifically designed to be used as the main panel disconnect for control panel applications IEC style rotary operating handles Equipped with a unique terminal design that makes converting between busbar and lug options easy Easy to install, extremely versatile, a wide variety of terminal options include mechanical lugs, crimp lugs, power distribution lugs and lug shields 65 kA at 240 VAC, 35 kA at 480 VAC, 25 kA at 600 VAC, 50 kA at 125 VDC, 50 kA at 250 VDC interrupt rating
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
Alternate Catalog Number | LHL36200 |
ARRA Compliant | N |
Buy American Compliant | N |
Catalog Number | LHL36200 |
Connection | AWG 1...600 KCMIL ALUMINIUM/COPPER)1 -AWG 1...250 KCMIL ALUMINIUM/COPPER)2,LUGS LOAD-LUGS LINE |
Connection Type | Line/Load Lug |
Country of Origin | US |
Currency | USD |
Dimensions | 11 in H x 6 in W x 5.84 in D |
Enclosure Type | NEMA 1/3R/12/4/4X/5 |
EU RoHS Indicator | Y |
Frame | LH Series |
Frequency Rating | 50/60 Hz |
Gross Weight Per Pack | 16.1800 lb |
Gross Weight per Pack Metric | 7.34 |
Gross Weight UOM Metric | kg |
Harmonization Tariff Schedule Code | 8536200020 |
Height | 21.4330 in |
Height [Metric] | 21.4330 cm |
Item Group | 00935 |
Length | 43.4980 in |
Length [Metric] | 43.4980 cm |
Material Composition Declaration | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=430225&lang=en-us |
Mounting Type | Unit |
Number Of Poles | 3 |
Phase | 3 pH |
Returnable | Y |
Standard | UL LISTED-IEC-CSA |
Temperature Rating | 104 °F |
Trip Range | 1000 to 2000 A |
Type | Adjustable High Interrupt |
UNSPSC | 39121601 |
UPC 11 | 78590108212 |
UPC 12 | 785901082125 |
Warranty Description | Contractual Warranty:18 months |
Width | 28.2580 in |
Width [Metric] | 28.2580 cm |
Wire Size | (1) 1 AWG to 600 kcmil/(2)1 AWG to 250 kcmil Al/Cu |
Stock Status | NONSTOCK |
Brand | Square D™ |
Manufacturer | Schneider Electric |
Amperage Rating | 200 A |
Interrupt Rating | 65 kA at 240 VAC/35 kA at 480 VAC/25 kA at 600 VAC/50 kA at 125/250 VDC |
Trip Type | Thermal Magnetic |
Voltage Rating | 600 VAC/250 VDC |
UNIT MOUNT |
Common accessories and auxiliaries with other PowerPact™ frames |
Common accessories across the range of PowerPact™ molded case circuit breakers allow users to make late specification changes |
A wide range of field installable accessories allows customers to reduce inventory without sacrificing flexibility |
Broad offering of operating mechanisms and ratings specifically designed to be used as the main panel disconnect for control panel applications |
IEC style rotary operating handles |
Equipped with a unique terminal design that makes converting between busbar and lug options easy |
Easy to install, extremely versatile, a wide variety of terminal options include mechanical lugs, crimp lugs, power distribution lugs and lug shields |
65 kA at 240 VAC, 35 kA at 480 VAC, 25 kA at 600 VAC, 50 kA at 125 VDC, 50 kA at 250 VDC interrupt rating |